CoChat

Radiofrequency Catheter Modification of Atrioventricular Conduction to Control the Ventricular Rate during Atrial Fibrillation

Williamson, Brian D., Man, K. Ching, Daoud, Emile, Niebauer, Mark, Strickberger, S. Adam, Morady, Fred · 1994 · New England Journal of Medicine
Cited by 246

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

BACKGROUND: In some patients with atrial fibrillation, the ventricular rate may be difficult to control with medications. We evaluated a radiofrequency catheter technique to modify atrioventricular conduction in atrial fibrillation in order to control the ventricular rate without creating pathologic atrioventricular block. METHODS: We studied 19 consecutive patients with atrial fibrillation and uncontrolled ventricular rates refractory to drug therapy. They had had atrial fibrillation for a mean (+/- SD) of 5.5 +/- 4.9 years, had had 4.9 +/- 0.9 unsuccessful drug trials, and were 62 +/- 15 years old. Before the procedure, the maximal ventricular rate during exercise was 180 +/- 39 beats per minute. A total of 11 +/- 5 radiofrequency-energy applications were delivered to the posterior septal or midseptal right atrium, near the ostium of the coronary sinus. RESULTS: Successful control of the ventricular rate without pathologic atrioventricular block was achieved in 14 of the 19 patients (74 percent). Persistent third-degree atrioventricular block requiring a permanent pacemaker occurred inadvertently in four patients (21 percent). Atrioventricular conduction was intentionally ablated in one patient. The 14 patients who had successful modification of conduction had persistent reductions in maximal ventricular rate during exercise (rate at three months, 126 +/- 24 beats per minute; P < 0.01). These patients had resolution of symptoms related to rapid rates during 8 +/- 2 months of follow-up. One patient had a recurrence of a rapid ventricular rate but was again asymptomatic after a second modification procedure. One patient with dilated cardiomyopathy died suddenly, five months after a successful procedure. CONCLUSIONS: A catheter technique to modify atrioventricular conduction without creating pathologic atrioventricular block is feasible in the majority of patients with symptomatic atrial fibrillation and a rapid ventricular rate refractory to drug therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199410063311404

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

Metadata

Authors
Williamson, B. D., Man, K. C., Daoud, E., Niebauer, M., Strickberger, S. A., & Morady, F.
Venue
New England Journal of Medicine
Published
1994-10-06
Volume
331
Issue
14
Pages
910-917
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2328455896
Cited by
246
References
23
FWCI
21.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.