CoChat

Anal Dynamic Graciloplasty in the Treatment of Intractable Fecal Incontinence

Open access
Baeten, Cor G.M.I., Geerdes, Bastiaan P., Adang, Eddy M.M., Heineman, Erik, Konsten, Joop, Engel, Gerard L., Kester, Arnold D.M., Spaans, Frank, Soeters, Peter B. · 1995 · New England Journal of Medicine
Cited by 325

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

BACKGROUND: In patients with intractable fecal incontinence, conventional treatment is not always successful. Dynamic graciloplasty (transposition of the gracilis muscle to the anus with the implantation of stimulating electrodes) was developed to provide such patients with functional neosphincters. We evaluated the clinical results of this new surgical approach and the effects on quality of life. METHODS: We treated 52 patients with dynamic graciloplasty. The clinical results of treatment were evaluated in an interview, by anal manometry, and by enema testing. The degree of continence was scored. To assess quality of life, four questionnaires were administered (parts 1 and 2 of the Nottingham Health Profile, the State-Trait Anxiety Inventory, and the Self-rating Depression scale). RESULTS: Among the 52 patients, 38 (73 percent) were continent after a median follow-up of 2.1 years. At 52 weeks the patients' condition had improved with respect to the median frequency of defecation (from five to two times per 24 hours, P < 0.001), the median time defecation could be postponed (from 9 seconds to 19 minutes, P = 0.012), and the median time an enema could be retained (from 0 to 180 seconds, P = 0.005). Patients in whom the technique was successful became less anxious than those in whom it failed (P = 0.002) and improved with regard to effectiveness in their occupations, ability to perform tasks around the home, personal relationships, sexual function, and social life (P = 0.01). They also became less isolated socially (P = 0.05). CONCLUSIONS: Dynamic graciloplasty is a safe and reliable technique in patients with severe incontinence and may result in a better quality of life.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199506153322403

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 325

Metadata

Authors
Baeten, C. G. M. I., Geerdes, B. P., Adang, E. M. M., Heineman, E., Konsten, J., Engel, G. L., Kester, A. D. M., Spaans, F., & Soeters, P. B.
Venue
New England Journal of Medicine
Published
1995-06-15
Volume
332
Issue
24
Pages
1600-1605
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2139006310
Cited by
325
References
16
FWCI
19.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.