Inhaled Nitric Oxide for High-Altitude Pulmonary Edema

Open access
Scherrer, Urs, Vollenweider, Laurent, Delabays, Alain, Savcic, Milos, Eichenberger, Urs, Kleger, Gian-Reto, Fikrle, Antonin, Ballmer, Peter E., Nicod, Pascal, Bärtsch, Peter·1996·New England Journal of Medicine

Abstract

BACKGROUND: Pulmonary hypertension is a hallmark of high-altitude pulmonary edema and may contribute to its pathogenesis. When administered by inhalation, nitric oxide, an endothelium-derived relaxing factor, attenuates the pulmonary vasoconstriction produced by short-term hypoxia. METHODS: We studied the effects of inhaled nitric oxide on pulmonary-artery pressure and arterial oxygenation in 18 mountaineers prone to high-altitude pulmonary edema and 18 mountaineers resistant to this condition in a high altitude laboratory (altitude, 4559 m). We also obtained lung-perfusion scans before and during nitric oxide inhalation to gain further insight into the mechanism of action of nitric oxide. RESULTS: In the high-altitude laboratory, subjects prone to high-altitude pulmonary edema had more pronounced pulmonary hypertension and hypoxemia than subjects resistant to high-altitude pulmonary edema. Arterial oxygen saturation was inversely related to the severity of pulmonary hypertension (r=-0.50, P=0.002). In subjects prone to high-altitude pulmonary edema, the inhalation of nitric oxide (40 ppm for 15 minutes) produced a decrease in mean (+/-SD) systolic pulmonary-artery pressure that was three times larger than the decrease in subjects resistant to such edema (25.9+/-8.9 vs. 8.7+/-4.8 mm Hg, P<0.001). Inhaled nitric oxide improved arterial oxygenation in the 10 subjects who had radiographic evidence of pulmonary edema (arterial oxygen saturation increased from 67+/-10 to 73+/-12 percent, P=0.047), whereas it worsened oxygenation in subjects resistant to high-altitude pulmonary edema. The nitric oxide-induced improvement in arterial oxygenation in subjects with high-altitude pulmonary edema was accompanied by a shift in blood flow in the lung away from edematous segments and toward nonedematous segments. CONCLUSIONS: The inhalation of nitric oxide improves arterial oxygenation in high-altitude pulmonary edema, and this beneficial effect may be related to its favorable action on the distribution of blood flow in the lungs. A defect in nitric nitric oxide synthesis may contribute to high-altitude pulmonary edema.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199603073341003

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 335

Metadata

Authors
Scherrer, U., Vollenweider, L., Delabays, A., Savcic, M., Eichenberger, U., Kleger, G.-R., Fikrle, A., Ballmer, P. E., Nicod, P., & Bärtsch, P.
Venue
New England Journal of Medicine
Published
1996-03-07
Volume
334
Issue
10
Pages
624-630
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2015247808
Cited by
335
References
1
FWCI
8.22
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inhaled Nitric Oxide for High-Altitude Pulmonary Edema. https://app.cochat.ai/papers/10.1056/nejm199603073341003
The paper
Scherrer, U., Vollenweider, L., Delabays, A., Savcic, M., Eichenberger, U., Kleger, G.-R., Fikrle, A., Ballmer, P. E., Nicod, P., & Bärtsch, P. (1996). Inhaled Nitric Oxide for High-Altitude Pulmonary Edema. New England Journal of Medicine. https://doi.org/10.1056/nejm199603073341003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.