CoChat

Effect of Theophylline on Sleep-Disordered Breathing in Heart Failure

Open access
Javaheri, S., Parker, T.J., Wexler, L., Liming, J.D., Lindower, P., Roselle, G.A. · 1996 · New England Journal of Medicine
Cited by 357

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Theophylline has been used to treat central apnea associated with Cheyne-Stokes respiration (periodic breathing). We studied the effect of short-term oral theophylline therapy on periodic breathing associated with stable heart failure due to systolic dysfunction. METHODS: Fifteen men with compensated heart failure (left ventricular ejection fraction, 45 percent or less) participated in the study. Their base-line polysomnograms showed periodic breathing, with more than 10 episodes of apnea and hypopnea per hour. In a double-blind crossover study, the patients received theophylline or placebo orally twice daily for five days, with one week of washout between the two periods. RESULTS: After five days of treatment, the mean (+/-SD) plasma theophylline concentration was 11 +/- 2 microgram per milliliter. Theophylline therapy resulted in significant decreases in the number of episodes of apnea and hypopnea per hour (18 +/- 17, vs. 37 +/- 23 with placebo and 47 +/- 21 at base line; P<0.001), the number of episodes of central apnea per hour (6 +/- 14, vs. 26 +/- 21 and 26 +/- 20, respectively; P<0.001), and the percentage of total sleep time during which the arterial oxyhemoglobin saturation was less than 90 percent (6 +/- 11 percent, vs., 23 +/- 37 and 14 +/- 14 percent, respectively; P<0.04). There were no significant differences in the characteristics of sleep, the frequency of ventricular arrhythmias, daytime arterial-blood gas values, or the left ventricular ejection fraction during the base-line, placebo, and theophylline phases of the study. CONCLUSIONS: In patients with stable heart failure, oral theophylline therapy reduced the number of episodes of apnea and hypopnea and the duration of arterial oxyhemoglobin desaturation during sleep.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199608223350805

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 357

Metadata

Authors
Javaheri, S., Parker, T. J., Wexler, L., Liming, J. D., Lindower, P., & Roselle, G. A.
Venue
New England Journal of Medicine
Published
1996-08-22
Volume
335
Issue
8
Pages
562-567
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2325281910
Cited by
357
References
24
FWCI
6.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.