Inhaled Nitric Oxide and Persistent Pulmonary Hypertension of the Newborn

Roberts, Jesse D., Fineman, Jeffrey R., Morin, Frederick C., Shaul, Philip W., Rimar, Stephen, Schreiber, Michael D., Polin, Richard A., Zwass, Maurice S., Zayek, Michael M., Gross, Ian, Heymann, Michael A., Zapol, Warren M., Thusu, Kajori G., Zellers, Thomas M., Wylam, Mark E., Zaslavsky, Alan · 1997 · New England Journal of Medicine
Cited by 804

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Persistent pulmonary hypertension of the newborn causes systemic arterial hypoxemia because of increased pulmonary vascular resistance and right-to-left shunting of deoxygenated blood. Inhaled nitric oxide decreases pulmonary vascular resistance in newborns. We studied whether inhaled nitric oxide decreases severe hypoxemia in infants with persistent pulmonary hypertension. METHODS: In a prospective, multicenter study, 58 full-term infants with severe hypoxemia and persistent pulmonary hypertension were randomly assigned to breathe either a control gas (nitrogen) or nitric oxide (80 parts per million), mixed with oxygen from a ventilator. If oxygenation increased after 20 minutes and systemic blood pressure did not decrease, the treatment was considered successful and was continued at lower concentrations. Otherwise, it was discontinued and alternative therapies, including extracorporeal membrane oxygenation, were used. RESULTS: Inhaled nitric oxide successfully doubled systemic oxygenation in 16 of 30 infants (53 percent), whereas conventional therapy without inhaled nitric oxide increased oxygenation in only 2 of 28 infants (7 percent). Long-term therapy with inhaled nitric oxide sustained systemic oxygenation in 75 percent of the infants who had initial improvement. Extracorporeal membrane oxygenation was required in 71 percent of the control group and 40 percent of the nitric oxide group (P=0.02). The number of deaths was similar in the two groups. Inhaled nitric oxide did not cause systemic hypotension or increase methemoglobin levels. CONCLUSIONS: Inhaled nitric oxide improves systemic oxygenation in infants with persistent pulmonary hypertension and may reduce the need for more invasive treatments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199702273360902

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 804

Metadata

Authors
Roberts, J. D., Fineman, J. R., Morin, F. C., Shaul, P. W., Rimar, S., Schreiber, M. D., Polin, R. A., Zwass, M. S., Zayek, M. M., Gross, I., Heymann, M. A., Zapol, W. M., Thusu, K. G., Zellers, T. M., Wylam, M. E., & Zaslavsky, A.
Venue
New England Journal of Medicine
Published
1997-02-27
Volume
336
Issue
9
Pages
605-610
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2324162185
Cited by
804
References
10
FWCI
64.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.