A Comparison of Two Antimicrobial-Impregnated Central Venous Catheters
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The use of central venous catheters impregnated with either minocycline and rifampin or chlorhexidine and silver sulfadiazine reduces the rates of catheter colonization and catheter-related bloodstream infection as compared with the use of unimpregnated catheters. We compared the rates of catheter colonization and catheter-related bloodstream infection associated with these two kinds of antiinfective catheters. METHODS: We conducted a prospective, randomized clinical trial in 12 university-affiliated hospitals. High-risk adult patients in whom central venous catheters were expected to remain in place for three or more days were randomly assigned to undergo insertion of polyurethane, triple-lumen catheters impregnated with either minocycline and rifampin (on both the luminal and external surfaces) or chlorhexidine and silver sulfadiazine (on only the external surface). After their removal, the tips and subcutaneous segments of the catheters were cultured by both the roll-plate and the sonication methods. Peripheral-blood cultures were obtained if clinically indicated. RESULTS: Of 865 catheters inserted, 738 (85 percent) produced culture results that could be evaluated. The clinical characteristics of the patients and the risk factors for infection were similar in the two groups. Catheters impregnated with minocycline and rifampin were 1/3 as likely to be colonized as catheters impregnated with chlorhexidine and silver sulfadiazine (28 of 356 catheters [7.9 percent] vs. 87 of 382 [22.8 percent], P<0.001), and catheter-related bloodstream infection was 1/12 as likely in catheters impregnated with minocycline and rifampin (1 of 356 [0.3 percent], vs. 13 of 382 [3.4 percent] for those impregnated with chlorhexidine and silver sulfadiazine; P<0.002). CONCLUSIONS: The use of central venous catheters impregnated with minocycline and rifampin is associated with a lower rate of infection than the use of catheters impregnated with chlorhexidine and silver sulfadiazine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methods for dilution antimicrobial susceptibility tests for bacteria that grow aerobically
Ferraro, M. J. (2000) · Medical Entomology and Zoology · Cited by 17,254
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Pittet, D. (1994) · JAMA · doi:10.1001/jama.1994.03510440058033 · Cited by 926
Maki, D. G., Stolz, S. M., Wheeler, S., & Mermel, L. A. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-4-199708150-00001 · Cited by 753
Raad, I., Darouiche, R., Dupuis, J., Abi-Said, D., Gabrielli, A., Hachem, R., Wall, M., Harris, R., Jones, J., Buzaid, A., et al. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-4-199708150-00002 · Cited by 610
Self-citation(1996) · American Journal of Infection Control · doi:10.1016/s0196-6553(96)90058-9 · Cited by 492
Heard, S. O., Wagle, M., Vijayakumar, E., McLean, S., Brueggemann, A., Napolitano, L. M., Edwards, L. P., O'Connell, F. M., Puyana, J. C., & Doern, G. V. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.1.81 · Cited by 473
Self-citationInfectious Complications of Indwelling Vascular Catheters
Raad, I. I., & Bodey, G. P. (1992) · Clinical Infectious Diseases · doi:10.1093/clinids/15.2.197 · Cited by 446
Self-citationSherertz, R. J., Raad, I. I., Belani, A., Koo, L. C., Rand, K. H., Pickett, D. L., Straub, S. A., & Fauerbach, L. L. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.1.76-82.1990 · Cited by 381
Self-citationThe Broad-Spectrum Activity and Efficacy of Catheters Coated with Minocycline and Rifampin
Raad, I., Darouiche, R., Hachem, R., Mansouri, M., & Bodey, G. P. (1996) · Journal of Infectious Diseases · doi:10.1093/infdis/173.2.418 · Cited by 249
Self-citationSalzman, M. B., Isenberg, H. D., Shapiro, J. F., Lipsitz, P. J., & Rubin, L. G. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/167.2.487 · Cited by 214
Antibiotics and prevention of microbial colonization of catheters
Raad, I., Darouiche, R., Hachem, R., Sacilowski, M., & Bodey, G. P. (1995) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.39.11.2397 · Cited by 211
Self-citationSherertz, R. J., Heard, S. O., & RAAD, I. I. (1997) · Journal of Clinical Microbiology · doi:10.1128/jcm.35.3.641-646.1997 · Cited by 155
Self-citationNo Difference in Catheter Sepsis Between Standard and Antiseptic Central Venous Catheters
Pemberton, L. B. (1996) · Archives of Surgery · doi:10.1001/archsurg.1996.01430210084018 · Cited by 137
Tennenberg, S. D. (1997) · Archives of Surgery · doi:10.1001/archsurg.1997.01430360094017 · Cited by 98
RAAD, I. I., Darouiche, R. O., Hachem, R. Y., Abi-Said, D., Safar, H., Darnule, T. V., Mansouri, M., & Morck, D. W. (1998) · Critical Care Medicine · doi:10.1097/00003246-199802000-00015 · Cited by 93
Self-citation
Cited by
Biofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644
Silver nanoparticles as a new generation of antimicrobials
Rai, M., Yadav, A., & Gade, A. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.09.002 · Cited by 6,173
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationPreventing Complications of Central Venous Catheterization
McGee, D. C., & Gould, M. K. (2003) · New England Journal of Medicine · doi:10.1056/nejmra011883 · Cited by 2,290
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Metadata
- Authors
- Darouiche, R. O., Raad, I. I., Heard, S. O., Thornby, J. I., Wenker, O. C., Gabrielli, A., Berg, J., Khardori, N., Hanna, H., Hachem, R., Harris, R. L., & Mayhall, G.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1999-01-07
- Volume
- 340
- Issue
- 1
- Pages
- 1-8
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2325546012
- Cited by
- 804
- References
- 16
- FWCI
- 102.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.