Effects of Physiologic Pacing versus Ventricular Pacing on the Risk of Stroke and Death Due to Cardiovascular Causes
Open accessAbstract
BACKGROUND: Evidence suggests that physiologic pacing (dual-chamber or atrial) may be superior to single-chamber (ventricular) pacing because it is associated with lower risks of atrial fibrillation, stroke, and death. These benefits have not been evaluated in a large, randomized, controlled trial. METHODS: At 32 Canadian centers, patients without chronic atrial fibrillation who were scheduled for a first implantation of a pacemaker to treat symptomatic bradycardia were eligible for enrollment. We randomly assigned patients to receive either a ventricular pacemaker or a physiologic pacemaker and followed them for an average of three years. The primary outcome was stroke or death due to cardiovascular causes. Secondary outcomes were death from any cause, atrial fibrillation, and hospitalization for heart failure. RESULTS: A total of 1474 patients were randomly assigned to receive a ventricular pacemaker and 1094 to receive a physiologic pacemaker. The annual rate of stroke or death due to cardiovascular causes was 5.5 percent with ventricular pacing, as compared with 4.9 percent with physiologic pacing (reduction in relative risk, 9.4 percent; 95 percent confidence interval, -10.5 to 25.7 percent [the negative value indicates an increase in risk]; P=0.33). The annual rate of atrial fibrillation was significantly lower among the patients in the physiologic-pacing group (5.3 percent) than among those in the ventricular-pacing group (6.6 percent), for a reduction in relative risk of 18.0 percent (95 percent confidence interval, 0.3 to 32.6 percent; P=0.05). The effect on the rate of atrial fibrillation was not apparent until two years after implantation. The observed annual rates of death from all causes and of hospitalization for heart failure were lower among the patients with a physiologic pacemaker than among those with a ventricular pacemaker, but not significantly so (annual rates of death, 6.6 percent with ventricular pacing and 6.3 percent with physiologic pacing; annual rates of hospitalization for heart failure, 3.5 percent and 3.1 percent, respectively). There were significantly more perioperative complications with physiologic pacing than with ventricular pacing (9.0 percent vs. 3.8 percent, P<0.001). CONCLUSIONS: Physiologic pacing provides little benefit over ventricular pacing for the prevention of stroke or death due to cardiovascular causes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In selected patients with sick sinus syndrome and fast ventricular response during AF paroxysms requiring rate control therapy, the addition of a pacemaker not only optimizes rate control but may also help to control rhythm.711,712”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [712]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer series in statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,239
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Evaluation of survival data and two new rank order statistics arising in its consideration.
Mantel, N. (1966) · PubMed · Cited by 7,516
Proportional hazards tests and diagnostics based on weighted residuals
GRAMBSCH, P. M., & THERNEAU, T. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.515 · Cited by 5,885
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381602 · Cited by 640
Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndrome
Andersen, H. R., Thuesen, L., Bagger, J. P., Vesterlund, T., & Thomsen, P. E. B. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90347-6 · Cited by 490
Rosenqvist, M., Brandt, J., & Schüller, H. (1988) · American Heart Journal · doi:10.1016/0002-8703(88)90244-x · Cited by 447
Research works printed but not linked: 3
- 10.2307/2281868 · DOI · Paper page
- Mantel N, 1966, Cancer Chemother Rep, 50, 163
- Wharton JM, 1998, Circulation, 98, I
Cited by
Sorted by citations
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Authors Task Force Members, Brignole, M., Auricchio, A., Barón‐Esquivias, G., Bordachar, P., Boriani, G., Breithardt, O. A., Cleland, J. G. F., Deharo, J.-C., Delgado, V., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,834
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Metadata
- Authors
- Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., Lau, C., & Newman, D. M.
- Affiliations
- McMaster University (CA)
- University of British Columbia (CA)
- University of Calgary (CA)
- McGill University (CA)
- Montreal Heart Institute (CA)
- University of Ottawa (CA)
- Western University (CA)
- University of Toronto (CA)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2000-05-11
- Volume
- 342
- Issue
- 19
- Pages
- 1385-1391
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2332653577
- Cited by
- 775
- References
- 16
- Citations by year
- 2026: 8 · 2025: 9 · 2024: 8 · 2023: 16 · 2022: 14 · 2021: 14 · 2020: 21 · 2019: 19 · 2018: 23 · 2017: 15 · 2016: 26 · 2015: 25 · 2014: 23 · 2013: 28 · 2012: 35
- FWCI
- 31.24
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- physiological pacing, ventricular pacing, dual-chamber pacemaker, atrial pacing, bradycardia, pacemaker implantation, stroke, cardiovascular mortality, atrial fibrillation, heart failure hospitalization, perioperative complications, symptomatic bradycardia
- MeSH terms
- Aged, Atrial Fibrillation, Bradycardia, Cardiac Pacing, Artificial, Cardiovascular Diseases, Female, Heart Block, Humans, Male, Pacemaker, Artificial, Risk, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review