The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Effects of Physiologic Pacing versus Ventricular Pacing on the Risk of Stroke and Death Due to Cardiovascular Causes
Open accessAbstract
BACKGROUND: Evidence suggests that physiologic pacing (dual-chamber or atrial) may be superior to single-chamber (ventricular) pacing because it is associated with lower risks of atrial fibrillation, stroke, and death. These benefits have not been evaluated in a large, randomized, controlled trial. METHODS: At 32 Canadian centers, patients without chronic atrial fibrillation who were scheduled for a first implantation of a pacemaker to treat symptomatic bradycardia were eligible for enrollment. We randomly assigned patients to receive either a ventricular pacemaker or a physiologic pacemaker and followed them for an average of three years. The primary outcome was stroke or death due to cardiovascular causes. Secondary outcomes were death from any cause, atrial fibrillation, and hospitalization for heart failure. RESULTS: A total of 1474 patients were randomly assigned to receive a ventricular pacemaker and 1094 to receive a physiologic pacemaker. The annual rate of stroke or death due to cardiovascular causes was 5.5 percent with ventricular pacing, as compared with 4.9 percent with physiologic pacing (reduction in relative risk, 9.4 percent; 95 percent confidence interval, -10.5 to 25.7 percent [the negative value indicates an increase in risk]; P=0.33). The annual rate of atrial fibrillation was significantly lower among the patients in the physiologic-pacing group (5.3 percent) than among those in the ventricular-pacing group (6.6 percent), for a reduction in relative risk of 18.0 percent (95 percent confidence interval, 0.3 to 32.6 percent; P=0.05). The effect on the rate of atrial fibrillation was not apparent until two years after implantation. The observed annual rates of death from all causes and of hospitalization for heart failure were lower among the patients with a physiologic pacemaker than among those with a ventricular pacemaker, but not significantly so (annual rates of death, 6.6 percent with ventricular pacing and 6.3 percent with physiologic pacing; annual rates of hospitalization for heart failure, 3.5 percent and 3.1 percent, respectively). There were significantly more perioperative complications with physiologic pacing than with ventricular pacing (9.0 percent vs. 3.8 percent, P<0.001). CONCLUSIONS: Physiologic pacing provides little benefit over ventricular pacing for the prevention of stroke or death due to cardiovascular causes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In selected patients with sick sinus syndrome and fast ventricular response during AF paroxysms requiring rate control therapy, the addition of a pacemaker not only optimizes rate control but may also help to control rhythm.711,712”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [712]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer series in statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,239
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Evaluation of survival data and two new rank order statistics arising in its consideration.
Mantel, N. (1966) · PubMed · Cited by 7,516
Proportional hazards tests and diagnostics based on weighted residuals
GRAMBSCH, P. M., & THERNEAU, T. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.515 · Cited by 5,885
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381602 · Cited by 640
Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndrome
Andersen, H. R., Thuesen, L., Bagger, J. P., Vesterlund, T., & Thomsen, P. E. B. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90347-6 · Cited by 490
Rosenqvist, M., Brandt, J., & Schüller, H. (1988) · American Heart Journal · doi:10.1016/0002-8703(88)90244-x · Cited by 447
Research works printed but not linked: 3
- 10.2307/2281868 · DOI · Paper page
- Mantel N, 1966, Cancer Chemother Rep, 50, 163
- Wharton JM, 1998, Circulation, 98, I
Cited by
Sorted by citations
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Authors Task Force Members, Brignole, M., Auricchio, A., Barón‐Esquivias, G., Bordachar, P., Boriani, G., Breithardt, O. A., Cleland, J. G. F., Deharo, J.-C., Delgado, V., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,834
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000072769.17295.b1 · Cited by 1,773
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,772
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,496
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Fuster, V., Rydén, L., Cannom, D. S., Crijns, H. J. G. M., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Heuzey, J. L., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.009 · Cited by 1,161
2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Authors Task Force Members, Brignole, M., Auricchio, A., Barón‐Esquivias, G., Bordachar, P., Boriani, G., Breithardt, O. A., Cleland, J. G. F., Deharo, J., Delgado, V., et al. (2013) · EP Europace · doi:10.1093/europace/eut206 · Cited by 1,137
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node Dysfunction
Lamas, G. A., Lee, K. L., Sweeney, M. O., Silverman, R., León, A. R., Yee, R. K., Marinchak, R. A., Flaker, G., SCHRON, E. B., Orav, E. J., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013040 · Cited by 994
Fuster, V., Rydén, L., Cannom, D. S., Crijns, H. J. G. M., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Huezey, J.-Y. L., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 928
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · EP Europace · doi:10.1093/europace/euab232 · Cited by 936
Guidelines for cardiac pacing and cardiac resynchronization therapy
Vardas, P. E., Auricchio, A., Blanc, J., Daubert, J., Drexler, H., Ector, H., Gasparini, M., Linde, C. M., Morgado, F. B., Oto, A., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 895
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 748
ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: full text
Fuster, V., Rydén, L., Cannom, D. S., Crijns, H. J. G. M., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Heuzey, J. L., Kay, G. N., Lowe, J. E., et al. (2006) · EP Europace · doi:10.1093/europace/eul097 · Cited by 670
Authors Task Force Members, Fuster, V., Rydén, L., Cannom, D. S., Crijns, H. J. G. M., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Heuzey, J. L., Kay, G. N., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl176 · Cited by 646
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare
Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., & Jung, J. (2019) · Nanomaterials · doi:10.3390/nano9060813 · Cited by 624
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 550
Minimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node Disease
Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D. A., Sheldon, T., & Lamas, G. A. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071880 · Cited by 518
Fuster, V., Rydén, L., ASINGER, R. W., Cannom, D. S., Crijns, H. J. G. M., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2983 · Cited by 491
Trends in Permanent Pacemaker Implantation in the United States From 1993 to 2009
Greenspon, A. J., Patel, J. D., Lau, E., Ochoa, J. A., Frisch, D. R., Ho, R. T., Pavri, B. B., & Kurtz, S. M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.017 · Cited by 476
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation
Fuster, V., Rydén, L., Cannom, D. S., Crijns, H. J. G. M., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Heuzey, J. L., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.018 · Cited by 468
The Cardiovascular Disease Continuum Validated: Clinical Evidence of Improved Patient Outcomes
Dzau, V. J., Antman, E. M., Black, H. R., Hayes, D. L., Manson, J. E., Plutzky, J., Popma, J. J., & Stevenson, W. G. (2006) · Circulation · doi:10.1161/circulationaha.106.655688 · Cited by 471
Capucci, A., Santini, M., Padeletti, L., Gulizia, M. M., Botto, G., Boriani, G., Ricci, R. P., Favale, S., Zolezzi, F., Belardino, N. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.044 · Cited by 400
Single-Chamber versus Dual-Chamber Pacing for High-Grade Atrioventricular Block
Toff, W. D., Camm, A. J., & Skehan, J. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042283 · Cited by 381
Steinberg, J. S., Fischer, A., Wang, P. J., Schuger, C. D., Daubert, J. P., McNitt, S. A., Andrews, M. L., Brown, M. W., Hall, W. J., Zaręba, W., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2005.50038.x · Cited by 346
Sharma, P. S., Dandamudi, G., Naperkowski, A., Oren, J. W., Storm, R. H., Ellenbogen, K. A., & Vijayaraman, P. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2014.10.021 · Cited by 388
Fuster, V., Rydén, L., Cannom, D. S., Crijns, H. J. G. M., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Heuzey, J. L., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177031 · Cited by 345
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.043 · Cited by 337
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.11.018 · Cited by 301
Linde, C. M., Bongiorni, M. G., Birgersdotter-Green, U. M., Curtis, A. B., Deisenhofer, I., Furokawa, T., Gillis, A. M., Haugaa, K. H., Lip, G. Y. H., Gelder, I. C. V., et al. (2018) · EP Europace · doi:10.1093/europace/euy067 · Cited by 308
A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome
Nielsen, J. C., Thomsen, P., Højberg, S., Møller, M., Vesterlund, T., Dalsgaard, D., Mortensen, L. S., Nielsen, T., Asklund, M., Friis, E. V., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr022 · Cited by 296
Guidelines for cardiac pacing and cardiac resynchronization therapy
Vardas, P. E., Auricchio, A., Blanc, J., Daubert, J., Drexler, H., Ector, H., Gasparini, M., Linde, C. M., Morgado, F. B., Oto, A., et al. (2007) · EP Europace · doi:10.1093/europace/eum189 · Cited by 290
Occhetta, E., Bortnik, M., Magnani, A., Francalacci, G., Piccinino, C., Plebani, L., & Marino, P. N. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.056 · Cited by 285
Cardiovascular Outcomes With Atrial-Based Pacing Compared With Ventricular Pacing
Healey, J. S., Toff, W. D., Lamas, G. A., Andersen, H., Thorpe, K. E., Ellenbogen, K. A., Lee, K. L., Skene, A. M., SCHRON, E. B., Skehan, J., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.610303 · Cited by 265
ZHANG, X., CHEN, H., Siu, C., Yiu, K., Chan, W.-S., LEE, K. L., Chan, H., LEE, S. W., Fu, G., Lau, C., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.01014.x · Cited by 262
Heart Failure During Cardiac Pacing
Sweeney, M. O., & Hellkamp, A. S. (2006) · Circulation · doi:10.1161/circulationaha.105.608356 · Cited by 252
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al‐Khatib, S. M., Almendral, J. M., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2015) · EP Europace · doi:10.1093/europace/euv411 · Cited by 243
Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review
Tjong, F. V. Y., & Reddy, V. Y. (2017) · Circulation · doi:10.1161/circulationaha.116.025037 · Cited by 228
Left ventricular function during and after right ventricular pacing
Nahlawi, M., Waligora, M., SPIES, S. M., Bonow, R. O., Kadish, A. H., & Goldberger, J. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.06.074 · Cited by 225
A New Paradigm for Physiologic Ventricular Pacing
Sweeney, M. O., & Prinzen, F. W. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.029 · Cited by 219
Progression to chronic atrial fibrillation after pacing: the Canadian Trial of Physiologic Pacing
Skanes, A. C., Krahn, A. D., Yee, R. K., Klein, G. J., Connolly, S. J., Kerr, C. R., Gent, M., Thorpe, K. E., & Roberts, R. S. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01326-2 · Cited by 221
Sinus Node and Atrial Arrhythmias
John, R. M., & Kumar, S. (2016) · Circulation · doi:10.1161/circulationaha.116.018011 · Cited by 219
Recalls and Safety Alerts Involving Pacemakers and Implantable Cardioverter-Defibrillator Generators
Maisel, W. H. (2001) · JAMA · doi:10.1001/jama.286.7.793 · Cited by 210
The effect of atrial pacing therapies on atrial tachyarrhythmia burden and frequency
Lee, M. A., Weachter, R., Pollak, S. J., Kremers, M. S., Naik, A. M., Silverman, R., Tuzi, J., Wang, W., Johnson, L. J., & Euler, D. E. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00426-1 · Cited by 200
2013 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy
Brignole, M., Auricchio, A., Barón‐Esquivias, G., Bordachar, P., Boriani, G., Breithardt, O. A., Cleland, J. G. F., Deharo, J.-C., Delgado, V., Elliott, P. M., et al. (2014) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.11.003 · Cited by 201
Canadian Trial of Physiological Pacing
Kerr, C. R., Connolly, S. J., Abdollah, H., Roberts, R. S., Gent, M., Yusuf, S., Gillis, A. M., Tang, A., Talajic, M. R., Klein, G. J., et al. (2004) · Circulation · doi:10.1161/01.cir.0000109490.72104.ee · Cited by 196
Lieberman, R. A., Padeletti, L., Schreuder, J. J., Jackson, K., Michelucci, A., Colella, A., Eastman, W., Valsecchi, S., & Hettrick, D. A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.04.099 · Cited by 189
Carlson, M. D., Wilkoff, B. L., Maisel, W. H., Carlson, M. D., Ellenbogen, K. A., Saxon, L. A., Prystowsky, E. N., Alpert, J. S., Cain, M. E., Ching, E. A., et al. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.08.029 · Cited by 177
Padeletti, L., Pürerfellner, H., Adler, S. W., Waller, T., Harvey, M. N., HORVITZ, L., Holbrook, R., Kempen, K. P., Mugglin, A. S., Hettrick, D. A., et al. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.03191.x · Cited by 177
Saksena, S., Prakash, A., Ziegler, P., Hummel, J. D., Friedman, P., Plumb, V. J., Wyse, D. G., Johnson, E., Fitts, S., & Mehra, R. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02068-5 · Cited by 171
Gras, D., Böcker, D., Lunati, M., Wellens, H. J. J., Calvert, M., Freemantle, N., Gervais, R., KAPPENBERGER, L. J., Tavazzi, L., Erdmann, E., et al. (2007) · EP Europace · doi:10.1093/europace/eum080 · Cited by 172
Olshansky, B., Day, J. D., Moore, S., Gering, L. E., Rosenbaum, M., McGuire, M., Brown, S., & Lerew, D. R. (2006) · Circulation · doi:10.1161/circulationaha.106.629428 · Cited by 169
Lampert, R., Chung, E. H., Ackerman, M. J., Arroyo, A. R., Darden, D., Deo, R., Dolan, J., Etheridge, S. P., Gray, B. R., Harmon, K. G., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.05.018 · Cited by 167
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000627 · Cited by 161
Gillis, A. M., Pürerfellner, H., Israel, C. W., Sunthorn, H., Kacet, S., Anelli-Monti, M., TANG, F., Young, M. E., & Boriani, G. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00422.x · Cited by 157
Permanent His-bundle pacing: seeking physiological ventricular pacing
Barba-Pichardo, R., Morina-Vazquez, P., Fernández-Gómez, J. M., Venegas‐Gamero, J., & Herrera-Carranza, M. (2010) · EP Europace · doi:10.1093/europace/euq038 · Cited by 152
Brunner, M. P. (2003) · European Heart Journal · doi:10.1016/j.ehj.2003.10.022 · Cited by 152
Thackray, S. D. R. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00199-4 · Cited by 151
Eberhardt, F., Bode, F., Bonnemeier, H., Boguschewski, F., Schlei, M., Peters, W., & Wiegand, U. K. H. (2005) · Heart · doi:10.1136/hrt.2003.025411 · Cited by 148
ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Nielsen, J. C., Petersen, H. H., Karlsen, F. M., Chri, L. S., & Haarbo, J. (2014) · Cited by 146
Link, M. S., Hellkamp, A. S., Estes, N. A. M., Orav, E. J., Ellenbogen, K. A., Ibrahim, B. B., Greenspon, A. J., Rizo-Patrón, C., Goldman, L., Lee, K. L., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.072 · Cited by 144
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.036 · Cited by 138
Cardiac pacing: the state of the art
Trohman, R. G., Kim, M. H., & Pinski, S. L. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17358-3 · Cited by 133
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Evaluating and managing bradycardia
Sidhu, S., & Marine, J. E. (2020) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2019.07.001 · Cited by 134
Hohnloser, S. H., Capucci, A., Fain, E. S., Gold, M. R., Gelder, I. C. V., Healey, J. S., Israel, C. W., Lau, C., Morillo, C. A., & Connolly, S. J. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.02.016 · Cited by 129
The Cardiovascular Disease Continuum Validated: Clinical Evidence of Improved Patient Outcomes
Dzau, V. J., Antman, E. M., Black, H. R., Hayes, D. L., Manson, J. E., Plutzky, J., Popma, J. J., & Stevenson, W. G. (2006) · Circulation · doi:10.1161/circulationaha.106.655761 · Cited by 130
Canadian Cardiovascular Society Atrial Fibrillation Guidelines 2010: Rate and Rhythm Management
Gillis, A. M., Verma, A., Talajic, M. R., Nattel, S., & Dorian, P. (2011) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2010.11.001 · Cited by 122
Practices and Outcome of Artificial Cardiac Pacing in 154 Dogs
Oyama, M. A., Sisson, D. D., & Lehmkuhl, L. B. (2001) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2001.tb02316.x · Cited by 123
Leitlinien zur Herzschrittmachertherapie
Lemke, B., Nowak, B., & Pfeiffer, D. (2005) · Zeitschrift für Kardiologie · doi:10.1007/s00392-005-0269-3 · Cited by 120
Armaganijan, L., Toff, W. D., Nielsen, J. C., Andersen, H., Connolly, S. J., Ellenbogen, K. A., & Healey, J. S. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03240.x · Cited by 117
Recommendations from the Heart Rhythm Society Task Force on Lead Performance Policies and Guidelines
Maisel, W. H., Hauser, R. G., Hammill, S. C., Hauser, R. G., Ellenbogen, K. A., Epstein, A. E., Hayes, D. L., Alpert, J. S., Berger, R. D., Curtis, A. B., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.024 · Cited by 114
Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Møller, M., Arnsbo, P., & Nielsen, J. C. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.04.014 · Cited by 112
Vijayaraman, P., Dandamudi, G., Worsnick, S. A., & Ellenbogen, K. A. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12571 · Cited by 111
Pacemaker implantation and quality of life in the Mode Selection Trial (MOST)
Fleischmann, K. E., Orav, E. J., Lamas, G. A., Mangione, C. M., SCHRON, E. B., Lee, K. L., & Goldman, L. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.02.1031 · Cited by 109
Catanzariti, D., Maines, M., Cemin, C., Gp, B., Marotta, T., & Vergara, G. (2006) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-9033-5 · Cited by 110
Monfredi, O., & Boyett, M. R. (2015) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2015.02.003 · Cited by 106
Long‐Term Complication Rates in Ventricular, Single Lead VDD, and Dual Chamber Pacing
WIEGAND, U. K. H., Bode, F., Bonnemeier, H., Eberhard, F., Schlei, M., & PETERS, W. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00303.x · Cited by 105
Relationship Between Pacemaker Dependency and the Effect of Pacing Mode on Cardiovascular Outcomes
Tang, A., Roberts, R. S., Kerr, C. R., Gillis, A. M., Green, M. S., Talajic, M. R., Yusuf, S., Abdollah, H., Gent, M., & Connolly, S. J. (2001) · Circulation · doi:10.1161/01.cir.103.25.3081 · Cited by 104
HRS/ACCF Expert Consensus Statement on Pacemaker Device and Mode Selection
Gillis, A. M., Russo, A. M., Ellenbogen, K. A., Swerdlow, C. D., Olshansky, B., Al‐Khatib, S. M., Beshai, J. F., McComb, J. M., Nielsen, J. C., Philpott, J. M., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.06.011 · Cited by 100
Management of atrial fibrillation in patients with heart failure
Neuberger, H., Mewis, C., van Veldhuisen, D. J., Schotten, U., Gelder, I. C. V., Allessie, M. A., & Böhm, M. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm341 · Cited by 101
Robinson, M., Healey, J. S., Eikelboom, J. W., Schulman, S., Morillo, C. A., Nair, G. M., Baranchuk, A. M., Ribas, S., Evans, G., Connolly, S. J., et al. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02247.x · Cited by 98
Ritter, P., Duray, G. Z., Zhang, S., Narasimhan, C., Soejima, K., Omar, R., Laager, V., Stromberg, K. D., Williams, E., Reynolds, D., et al. (2015) · EP Europace · doi:10.1093/europace/euv026 · Cited by 94
Reasons for Escalating Pacemaker Implants
Birnie, D. H., Williams, K., Guo, A., Mielniczuk, L. M., Davis, D. R., Lemery, R., Green, M. S., Gollob, M. H., & Tang, A. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.01.069 · Cited by 93
Blanc, J. (2004) · EP Europace · doi:10.1016/j.eupc.2004.05.002 · Cited by 92
Dretzke, J., Toff, W. D., Lip, G. Y., Raftery, J., Fry-Smith, A., & Taylor, R. S. (2004) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003710.pub2 · Cited by 89
FUNCK, R. C., Mueller, H.-H., Lunati, M., Piorkowski, C., Roy, L. D., Paul, V., Wittenberg, M., Wuensch, D., & Blanc, J. (2013) · EP Europace · doi:10.1093/europace/eut343 · Cited by 88
Bradiarritmias y bloqueos de la conducción
Vogler, J., Breithardt, G., & Eckardt, L. (2012) · Revista Española de Cardiología · doi:10.1016/j.recesp.2012.01.025 · Cited by 90
Long-Term outcomes of cardiac pacing in adults with congenital heart disease
Walker, F., Siu, S. C., Woods, S., CAMERON, D. A., Webb, G. D., & Harris, L. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.044 · Cited by 84
Gillis, A. M., Unterberg‐Buchwald, C., Schmidinger, H., Santini, M., Wolfe, K., Kavaney, D. J., Otterness, M. F., & Hohnloser, S. H. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02345-8 · Cited by 84
Kristensen, L., Nielsen, J. C., Mortensen, P. T., Pedersen, O. L., Pedersen, A. K., & Andersen, H. R. (2004) · Heart · doi:10.1136/hrt.2003.016063 · Cited by 84
Evidence Base for Pacemaker Mode Selection
Lamas, G. A., Ellenbogen, K. A., & With the Assistance of Charles H. Hennekens, M. (2004) · Circulation · doi:10.1161/01.cir.0000115642.05037.0e · Cited by 79
Cardiac Implantable Electronic Devices
Al‐Khatib, S. M. (2024) · New England Journal of Medicine · doi:10.1056/nejmra2308353 · Cited by 78
Metadata
- Authors
- Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., Lau, C., & Newman, D. M.
- Affiliations
- McMaster University (CA)
- University of British Columbia (CA)
- University of Calgary (CA)
- McGill University (CA)
- Montreal Heart Institute (CA)
- University of Ottawa (CA)
- Western University (CA)
- University of Toronto (CA)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2000-05-11
- Volume
- 342
- Issue
- 19
- Pages
- 1385-1391
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2332653577
- Cited by
- 775
- References
- 16
- Citations by year
- 2026: 8 · 2025: 9 · 2024: 8 · 2023: 16 · 2022: 14 · 2021: 14 · 2020: 21 · 2019: 19 · 2018: 23 · 2017: 15 · 2016: 26 · 2015: 25 · 2014: 23 · 2013: 28 · 2012: 35
- FWCI
- 31.24
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- physiological pacing, ventricular pacing, dual-chamber pacemaker, atrial pacing, bradycardia, pacemaker implantation, stroke, cardiovascular mortality, atrial fibrillation, heart failure hospitalization, perioperative complications, symptomatic bradycardia
- MeSH terms
- Aged, Atrial Fibrillation, Bradycardia, Cardiac Pacing, Artificial, Cardiovascular Diseases, Female, Heart Block, Humans, Male, Pacemaker, Artificial, Risk, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review