Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 6,902

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection Fraction

Open access
Moss, Arthur J., Zareba, Wojciech, Hall, W. Jackson, Klein, Helmut, Wilber, David J., Cannom, David S., Daubert, James P., Higgins, Steven L., Brown, Mary W., Andrews, Mark L.·2002·New England Journal of Medicine

Abstract

BACKGROUND: Patients with reduced left ventricular function after myocardial infarction are at risk for life-threatening ventricular arrhythmias. This randomized trial was designed to evaluate the effect of an implantable defibrillator on survival in such patients. METHODS: Over the course of four years, we enrolled 1232 patients with a prior myocardial infarction and a left ventricular ejection fraction of 0.30 or less. Patients were randomly assigned in a 3:2 ratio to receive an implantable defibrillator (742 patients) or conventional medical therapy (490 patients). Invasive electrophysiological testing for risk stratification was not required. Death from any cause was the end point. RESULTS: The clinical characteristics at base line and the prevalence of medication use at the time of the last follow-up visit were similar in the two treatment groups. During an average follow-up of 20 months, the mortality rates were 19.8 percent in the conventional-therapy group and 14.2 percent in the defibrillator group. The hazard ratio for the risk of death from any cause in the defibrillator group as compared with the conventional-therapy group was 0.69 (95 percent confidence interval, 0.51 to 0.93; P=0.016). The effect of defibrillator therapy on survival was similar in subgroup analyses stratified according to age, sex, ejection fraction, New York Heart Association class, and the QRS interval. CONCLUSIONS: In patients with a prior myocardial infarction and advanced left ventricular dysfunction, prophylactic implantation of a defibrillator improves survival and should be considered as a recommended therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa013474

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 6,902

Metadata

Authors
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L.
Venue
New England Journal of Medicine
Published
2002-03-21
Volume
346
Issue
12
Pages
877-883
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2012574332
Cited by
6,902
References
3
FWCI
206.35
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.