The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enoxaparin versus Unfractionated Heparin in Elective Percutaneous Coronary Intervention
Open accessAbstract
BACKGROUND: Despite its limitations, unfractionated heparin has been the standard anticoagulant used during percutaneous coronary intervention (PCI). Several small studies have suggested that intravenous enoxaparin may be a safe and effective alternative. Our primary aim was to assess the safety of enoxaparin as compared with that of unfractionated heparin in elective PCI. METHODS: In this prospective, open-label, multicenter, randomized trial, we randomly assigned 3528 patients with PCI to receive enoxaparin (0.5 or 0.75 mg per kilogram of body weight) or unfractionated heparin adjusted for activated clotting time, stratified according to the use or nonuse of glycoprotein IIb/IIIa inhibitors. The primary end point was the incidence of major or minor bleeding that was not related to coronary-artery bypass grafting. The main secondary end point was the percentage of patients in whom the target anticoagulation levels were reached. RESULTS: Enoxaparin at a dose of 0.5 mg per kilogram was associated with a significant reduction in the rate of non-CABG-related bleeding in the first 48 hours, as compared with unfractionated heparin (5.9% vs. 8.5%; absolute difference, -2.6; 95% confidence interval [CI], -4.7 to -0.6; P=0.01), but the higher enoxaparin dose was not (6.5% vs. 8.5%; absolute difference, -2.0; 95% CI, -4.0 to 0.0; P=0.051). The incidence of major bleeding was significantly reduced in both enoxaparin groups, as compared with the unfractionated heparin group. Target anticoagulation levels were reached in significantly more patients who received enoxaparin (0.5-mg-per-kilogram dose, 79%; 0.75-mg-per-kilogram dose, 92%) than who received unfractionated heparin (20%, P<0.001). CONCLUSIONS: In elective PCI, a single intravenous bolus of 0.5 mg of enoxaparin per kilogram is associated with reduced rates of bleeding, and a dose of 0.75 mg per kilogram yields rates similar to those for unfractionated heparin, with more predictable anticoagulation levels. The trial was not large enough to provide a definitive comparison of efficacy in the prevention of ischemic events. (ClinicalTrials.gov number, NCT00077844 [ClinicalTrials.gov].).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An improved Bonferroni procedure for multiple tests of significance
SIMES, R. J. (1986) · Biometrika · doi:10.1093/biomet/73.3.751 · Cited by 2,396
Cited by
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Self-citation2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
Self-citation2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Self-citationBedside monitoring to adjust antiplatelet therapy for coronary stenting
Collet, J.-P., Cuisset, T., Rangé, G., Cayla, G., Elhadad, S., Pouillot, C., Henry, P., Motreff, P., Carrié, D., Boueri, Z., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1209979 · Cited by 887
Self-citation
Metadata
- Authors
- Montalescot, G., White, H. D., Gallo, R., Cohen, M., Steg, P. G., Aylward, P. E. G., Bode, C., Chiariello, M., King, S. B., Harrington, R. A., Desmet, W. J., Macaya, C., & Steinhubl, S. R.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2006-09-07
- Volume
- 355
- Issue
- 10
- Pages
- 1006-1017
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2141192690
- Cited by
- 359
- References
- 1
- FWCI
- 25.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.