Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
BACKGROUND: For patients who have a ventricular tachyarrhythmic event, implantable cardioverter-defibrillators (ICDs) are a mainstay of therapy to prevent sudden death. However, ICD shocks are painful, can result in clinical depression, and do not offer complete protection against death from arrhythmia. We designed this randomized trial to examine whether prophylactic radiofrequency catheter ablation of arrhythmogenic ventricular tissue would reduce the incidence of ICD therapy. METHODS: Eligible patients with a history of a myocardial infarction underwent defibrillator implantation for spontaneous ventricular tachycardia or fibrillation. The patients did not receive antiarrhythmic drugs. Patients were randomly assigned to defibrillator implantation alone or defibrillator implantation with adjunctive catheter ablation (64 patients in each group). Ablation was performed with the use of a substrate-based approach in which the myocardial scar is mapped and ablated while the heart remains predominantly in sinus rhythm. The primary end point was survival free from any appropriate ICD therapy. RESULTS: The mortality rate 30 days after ablation was zero, and there were no significant changes in ventricular function or functional class during the mean (+/-SD) follow-up period of 22.5+/-5.5 months. Twenty-one patients assigned to defibrillator implantation alone (33%) and eight patients assigned to defibrillator implantation plus ablation (12%) received appropriate ICD therapy (antitachycardia pacing or shocks) (hazard ratio in the ablation group, 0.35; 95% confidence interval, 0.15 to 0.78, P=0.007). Among these patients, 20 in the control group (31%) and 6 in the ablation group (9%) received shocks (P=0.003). Mortality was not increased in the group assigned to ablation as compared with the control group (9% vs. 17%, P=0.29). CONCLUSIONS: In this randomized trial, prophylactic substrate-based catheter ablation reduced the incidence of ICD therapy in patients with a history of myocardial infarction who received ICDs for the secondary prevention of sudden death. (Current Controlled Trials number, ISRCTN62488166 [controlled-trials.com].).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the Substrate Mapping and Ablation in Sinus Rhythm to Halt Ventricular Tachycardia (SMASH-VT) trial, 30 which randomly assigned 128 ICD patients with a history of ventricular arrhythmia and myocardial infarction to ablation or usual care, arrhythmia recurrence was significantly decreased from 33% to 12% with ablation.”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [30]
Citations
Cites
(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction
Hohnloser, S. H., Kuck, K. H., Dorian, P., Roberts, R. S., Hampton, J. R., Hatala, R., Fain, E., Gent, M., & Connolly, S. J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041489 · Cited by 1,519
Marchlinski, F. E., Callans, D. J., Gottlieb, C. D., & Zado, E. (2000) · Circulation · doi:10.1161/01.cir.101.11.1288 · Cited by 1,220
Moss, A. J., Greenberg, H., Case, R. B., Zareba, W., Hall, W. J., Brown, M. W., Daubert, J. P., McNitt, S., Andrews, M. L., & Elkin, A. D. (2004) · Circulation · doi:10.1161/01.cir.0000150390.04704.b7 · Cited by 597
Prevention of Implantable-Defibrillator Shocks by Treatment with Sotalol
Pacifico, A., Hohnloser, S. H., Williams, J. H., Tao, B., Saksena, S., Henry, P. D., & Prystowsky, E. N. (1999) · New England Journal of Medicine · doi:10.1056/nejm199906173402402 · Cited by 422
Guiraudon, G., Fontaine, G., Frank, R., Escande, G., Etievent, P., & Cabrol, C. (1978) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)62923-2 · Cited by 404
Electrical storm in patients with transvenous implantable cardioverter-defibrillators
Credner, S. C., Klingenheben, T., Mauss, O., Sticherling, C., & Hohnloser, S. H. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00495-1 · Cited by 376
Arenal, A., Glez-Torrecilla, E., Ortiz, M., Villacastín, J., Fdez-Portales, J., Sousa, E., del Castillo, S., Perez de Isla, L., Jimenez, J., & Almendral, J. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02623-2 · Cited by 343
Implantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger, Z., & Lampert, R. (2006) · JAMA · doi:10.1001/jama.295.7.809 · Cited by 271
Research works printed but not linked: 1
- Stevenson WG, 2005, Curr Opin Cardiol, 20, 42
Cited by
Items 801–900 of 964
A real-time tip manometer for radiofrequency catheter ablation: new toy or useful tool?
Zellerhoff, S., Eckardt, L., & Kirchhof, P. F. (2010) · EP Europace · doi:10.1093/europace/euq441
Rordorf, R., Vicentini, A., Savastano, S., Gandolfi, E., & Landolina, M. (2010) · Giornale italiano di cardiologia · doi:10.1714/660.7685
Randolph, T. C., & Piccini, J. P. (2013) · Heart Failure Clinics · doi:10.1016/j.hfc.2013.04.006
Arimoto, T., Tada, H., Sekiguchi, Y., Koyama, T., Igarashi, M., Yamasaki, H., Machino, T., Kuroki, K., Kuga, K., & Aonuma, K. (2009) · Journal of Arrhythmia · doi:10.1016/s1880-4276(09)80003-3
Winters, S. L., & Curwin, J. H. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03437.x
Nakahara, S., Hori, Y., Kobayashi, S., Tsukada, N., Sakai, Y., & Takayanagi, K. (2013) · Journal of Arrhythmia · doi:10.1016/j.joa.2013.09.008
“Catheter ablation has played an increasingly important role in controlling VT episodes in patients with structural heart disease who have an ICD [6–10].”
BackgroundLiew, R. (2011) · Heart · doi:10.1136/heartjnl-2011-300950
“This study is in accordance with an earlier prospective randomised study of 128 patients, which demonstrated that prophylactic catheter ablation of the ventricular arrhythmogenic substrate reduced the incidence of ICD therapy in patients with a history of myocardial infarction and previous ventricular arrhythmias.(85)…”
ResultKrummen, D. E., Oshodi, G., & Narayan, S. M. (2010) · Springer eBooks · doi:10.1007/978-1-4419-6691-9_1 · Cited by 2
“VT ablation often involves creation of a left ventricular endocardial and sometimes epicardial anatomy, and a combination of scar, pace, and entrainment mapping (Fig. 1.3) to locate and ablate critical isthmuses [ 58 ].”
BackgroundInfluentialIntracardiac echocardiography in premature ventricular complex/ventricular tachycardia ablation
Kim, T., & Kim, S. (2013)
Beleslin, B., Deljanin, M., Kanjuh, V., Parapid, B. J., Giga, V. L., Prostran, M. S., Angelkov, L., Balinovac, J., Bikicki, M., Ambrosio, G., et al. (2013)
Potratz, J. (2015) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-015-0355-9
PEMETAAN DAN ABLASI PADA TAKIKARDIA VENTRIKEL AKIBAT PARUT
Wangko, L. C., & Jim, E. L. (2015) · Jurnal Biomedik JBM · doi:10.35790/jbm.7.3.2015.10438
Long-Term Mortality After Ablation of Ischemic Ventricular Tachycardia
Wilber, D. J. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.037
Indications des ablations dans le traitement des arythmies cardiaques
Moubarak, G., & Anselme, F. (2015) · Réanimation · doi:10.1007/s13546-015-1040-z
Constâncio, V. (2015) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/6e6v-0g52
Current Approaches to Treatment of Ventricular Arrhythmias in Patients with Coronary Artery Disease
Jacobson, J. T., Iwai, S., & Aronow, W. S. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802385-3.00012-7 · Cited by 1
Management of the Electrical Storm in Patients with ICD
Muser, D., Facchin, D., Rebellato, L., & Proclemer, A. (2015) · Springer eBooks · doi:10.1007/978-3-319-24328-3_12
Ávila, P., Arenal, Á., & de Cardiología, S. (2016)
Link, M. S. (2007) · Journal watch · doi:10.1056/jc200712260000001
Buchta, P., Arya, A., Hindricks, G., Piorkowski, C., Poloński, L., Gąsior, M., & Zembala, M. (2012) · PubMed
Liew, R. (2012) · The Egyptian Heart Journal · doi:10.1016/j.ehj.2012.02.007
Transmural Myocardial Infarction
Lahiji, K., & Fardanesh, R. (2014) · Oxford University Press eBooks · doi:10.1093/med/9780199829477.003.0053
Catheter Ablation for Ventricular Tachycardia in Patients With Structural Heart Disease
Stevenson, W. G., & Tedrow, U. B. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-2856-5.00124-2
Fundamentals of Regenerative Medicine and Its Applications to Electrophysiology
Lau, D. H., & Rosen, M. R. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00009-0
Essentials of Imaging and Imaging Technologies Related to Arrhythmias
Sra, J. S., Anand, R. G., Dickfeld, T.-M. L., Mehta, A. M., & Nanda, N. C. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00017-x
Kataria, V., Yaduvanshi, A., & Nair, M. (2016) · Interventional Cardiology · doi:10.4172/interventional-cardiology.1000520
“From the fundamental understanding of the reentrant mechanism in scar-mediated VT to the advent and routine implementation of electroanatomic mapping, catheter ablation has emerged from a palliative last-resort therapy to a more preemptive strategy for patients at risk for arrhythmia recurrence [2].”
BackgroundSantangeli, P., Biase, L. D., Al‐Ahmad, A., & Natale, A. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-2856-5.00121-7
Patient with multiple ICD interventions (RCD code: V-2A.O)
Liszniański, P., Nowak, P., & Stryjewski, P. J. (2016) · Journal of Rare Cardiovascular Diseases · doi:10.20418/jrcd.vol3no1.261
“A number of reports have emphasized the fact, that ablation is a therapeutic option in the case of recurrent VT [9,10].”
BackgroundKatheterablation ventrikulärer Tachyarrhythmien
Konrad, T., Hoffmann, B. A., & Rostock, T. (2017) · Herz · doi:10.1007/s00059-017-4544-7
Current Management of Ventricular Tachycardia: Approaches and Timing
John, R. M., & Stevenson, W. G. (2016) · Cardiovascular Innovations and Applications · doi:10.15212/cvia.2015.0015
3-D-Mapping und Ablation bei Postinfarktpatienten mit rezidivierenden Kammertachykardien
Wasmer, K., & Eckardt, L. (2017) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-017-0506-2
“Eine der initial entwickelten substratbasierten Ablationsstrategien ist die lineare Ablation von der dichten Narbe durchdasNarbenrandgebiet zu anatomischen Barrieren, v. a. dem Mitralanulus, oder ins gesunde Myokard [18].”
BackgroundInfluentialRoukoz, H., Adkisson, W. O., Akdemir, B., Krishnan, B., Sakaguchi, S., & Benditt, D. G. (2017) · Springer eBooks · doi:10.1007/978-3-319-44577-9_19
OBSOLETE: Management of Ventricular Tachycardia in Ischemic and Nonischemic Cardiomyopathy
Sapp, J. L. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99776-9
Goya, M. (2013) · Japanese Journal of Electrocardiology · doi:10.5105/jse.33.252
Editorial Commentary: Indications for catheter ablation of ventricular tachycardia in the modern era
Saour, B., & Knight, B. P. (2017) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2017.06.011
OBSOLETE: Cardiac Arrhythmias in Heart Failure
Kalbfleisch, S. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99644-2
Ventricular Tachycardia Ablation
Baldinger, S. H., Tedrow, U. B., & Stevenson, W. G. (2017) · Cardiovascular medicine · doi:10.1007/978-3-319-58000-5_13
Boldly Going Where Few Have Gone Before
Chung, M. K., & Sridhar, A. R. M. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.06.010
Yoshie, K., & Ajijola, O. A. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.037
OBSOLETE: Catheter Ablation for Ventricular Tachycardia
John, R. M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99778-2
Kamrai tachycardiák katéterablációs kezelése
Clemens, M. (2017) · Cardiologia Hungarica · doi:10.26430/chungarica.2017.47.3.205
Coronary revascularization: A useful antiarrhythmic approach?
Klein, H. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13372
Reynolds, M. R. (2018) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.03.004
“Decades later, catheter ablation has an established role in the management of recurrent postinfarction VT, yet our knowledge about the effectiveness of VT ablation derives mainly from observational studies and only a few randomized clinical trials (8,9).”
BackgroundSelf-citationImplantable Cardioverter-defibrillator Use in Structural Heart Disease: Narrowing the Playing Field
Ellis, C. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090207
2018 KHRS Guidelines for Catheter Ablation of Ventricular Arrhythmias – Part3
Cho, Y., Kim, S., Kim, Y. R., Kim, Y.-N., Kim, J.-Y., Kim, T., Nam, G., Roh, S., Park, K., Park, H., et al. (2018) · International Journal of Arrhythmia · doi:10.18501/arrhythmia.2018.008
Frankel, D. S., & Marchlinski, F. E. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-44733-1.00084-5
Catheter ablation of ventricular tachycardia in structural heart disease: current perspectives
Peichl, P., & Kautzner, J. (2018) · Intervenční a akutní kardiologie · doi:10.36290/kar.2018.043
Lebedev, D. S., Tatarskiy, R. B., & Михайлов, Г. В. (2009) · Arterial’naya Gipertenziya (Arterial Hypertension) · doi:10.18705/1607-419x-2009-15-2-195-202
Biase, L. D., Aagaard, P., Santangeli, P., & Natale, A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-44733-1.00124-3
Mapping and Ablation of Ventricular Tachycardia in Coronary Artery Disease
Tanawuttiwat, T., & Marine, J. E. (2019) · Wiley eBooks · doi:10.1002/9781119152637.ch79
Catheter ablation of ventricular tachycardias: review of literature and own experience
Peichl, P., & Kautzner, J. (2010) · Cor et Vasa · doi:10.33678/cor.2010.004
Ventricular Tachycardia with Structural Heart Disease
Ding, L., & Yao, Y. (2019) · Springer eBooks · doi:10.1007/978-3-030-16992-3_13
Novel techniques for mapping and ablating ventricular Tachycardia
Jamil‐Copley, S. (2014) · Spiral (Imperial College London) · doi:10.25560/70326
Time to pause ventricular tachycardia: the PAUSE-SCD trial
Briceno, D. F., Romero, J. E., Alviz, I., Tarantino, N. M., & Biase, L. D. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00630-y
Herzinsuffizienz und Arrhythmien
Stellbrink, C. (2019) · Aktuelle Kardiologie · doi:10.1055/a-1027-6448
“Daher sollte die Indikation zur ICD-Implantation nicht nur unter Berücksichtigung der linksventrikulären Funktion allein erfolgen, sondern andere Faktoren (Alter, Komorbiditäten) verstärkt einbeziehen.”
BackgroundInfluentialVentricular tachycardia ablation in patients with structural heart disease: single centre experience
Uslu, A., Küp, A., Demır, S., Gülşen, K., Kayan, F., Kepez, A., & Akgün, T. (2020) · Marmara medical journal · doi:10.5472/marumj.681982
Quand ablater ou pas une tachycardie ventriculaire ?
Sacher, F., Duchâteau, J., Cochet, H., & Jaı̈s, P. (2020) · Archives des Maladies du Coeur et des Vaisseaux - Pratique · doi:10.1016/j.amcp.2020.02.005
Báez-Escudero, J. L., & ́bano, M. V. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-4815-0.00036-2
Actualización en cardiología geriátrica
Martínez‐Sellés, M., López‐Palop, R., Datino, T., & Bañuelos, C. (2009) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(09)71772-8
Yakut, İ., Kanal, Y., Kara, M., Korkmaz, A., Özeke, Ö., Çay, S., Özcan, F., Topaloğlu, S., & Aras, D. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13942
Catheter Ablation of Ventricular Tachycardia
Gomes, J. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-45066-3_14
Catheter ablation of ventricular arrhythmias associated with structural heart disease
Nagarajan, D. V., & Ernst, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817728-0.00056-5
Krisai, P., Vlachos, K. G., & Jaı̈s, P. (2020) · Circulation · doi:10.1161/circulationaha.120.047003
Factors associated with recurrent postinfarction ventricular tachycardia following ablation
Kewcharoen, J., Prasitlumkum, N., Titichoatrattana, S., Wittayalikit, C., Trongtorsak, A., Kanitsoraphan, C., Putthapiban, P., Poonsombudlert, K., Rattanawong, P., & Chung, E. H. (2021) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.20.05128-2
Substrate-Based Ablation for Ventricular Tachycardia
Tzou, W. S., & Sauer, W. H. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-52992-1.00033-8
Guias de ablación de arritmias cardíacas de la Federación Argentina de Cardiología
Keegan, R., Aguinaga, L., Secchi, J., Pozzer, D. L., Valentino, M., Femenía, F., Río, A. D., Feo, M. D., Bravo, A., & Martellotto, A. (2012) · Cited by 1
Suzuki, M., Ohkawa, Y., Yokoyama, H., Ito, T., Morimoto, K., & Ohori, S. (2021) · Japanese Journal of Cardiovascular Surgery · doi:10.4326/jjcvs.50.174
Prevention and Management of Perioperative Dysrhythmias
Esper, S. A., & Mahajan, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-56724-4.00015-0
Velagić, V., Puljević, D., Pezo-Nikolić, B., Puljević, M., & Miličić, D. (2019) · Liječnički vjesnik · doi:10.26800/lv-141-5-6-19
Treatment of Electrical Storm – the Electrophysiologist’s Point of View
Bardyszewski, A., Kuśnierz, J., & Derejko, P. (2017) · In a good rythm · doi:10.5604/01.3001.0010.3965
Advances in Mapping of Ventricular Tachycardia
Sanhueza, E. J., Malweera, A. S. N., Kumar, S. K., & Singh, S. M. (2021) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-021-00951-0
Repetitive ICD Shocks and Incessant VTs in Heart Failure: What to Do?
Eisenberger, M., Potter, T. J. R. D., & Geelen, P. (2013) · Springer eBooks · doi:10.1007/978-1-4614-7345-9_7
Nakasone, K., Fukuzawa, K., Kiuchi, K., Takami, M., Sakai, J., Nakamura, T., Yatomi, A., Sonoda, Y., Takahara, H., Yamamoto, K., et al. (2021) · doi:10.22541/au.163879412.24961373/v1
Actualización en arritmias y electrofisiología cardiaca
Arenal, Á., Castel, M., López‐Gil, M., & Merino, J. L. (2009) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(09)71773-x
Active Ventricular Arrhythmias
de Luna, A. B., & FCCS, A. B. M. F. F. (2017) · Wiley eBooks · doi:10.1002/9781119212782.ch5
Kida, Y. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60380-7
Kheiri, B., Simpson, T. F., & Nazer, B. (2020) · doi:10.22541/au.159605913.35668145
Cardiac Arrhythmia in Heart Failure
Okabe, T., & Kalbfleisch, S. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99644-3
Ablation of Ventricular Tachycardia in Coronary Artery Disease
Haqqani, H. M., & Callans, D. J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-52992-1.00030-2
Aggarwal, N. R., & Russo, A. M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-819369-3.00024-1
Catheter ablation reduces the incidence of shocks from ICDs
(2008) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio1142
Copyright and licensing of E-journals: Perspective from E-journals in J-STAGE
耕平, 石., & 英夫, 岡. (2017) · Japanese Journal of Electrocardiology · doi:10.5105/jse.37.198
Paulin, F. L., & Exner, D. V. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1367-1.00081-1
Management of Ventricular Tachycardia in Ischemic and Nonischemic Cardiomyopathy
AbdelWahab, A., Kuriachan, V. P., Sumner, G., Mitchell, L. B., & Sapp, J. L. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99776-x
Catheter Ablation of Arrhythmias
Wylie, J. V., Wrobleski, D., & Josephson, M. E. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-5225-8.00085-4
Self-citationbrenyo, A. J., Prinzi, T., & Huang, D. T.-C. (2014) · In clinical practice · doi:10.1007/978-1-4471-5433-4_7
Nuclear Imaging Guidance for Ablation of Ventricular Arrhythmias
Duell, J., Smith, M. F., Chen, W., Dilsizian, V., & Dickfeld, T.-M. L. (2019) · Wiley eBooks · doi:10.1002/9781118754467.ch14
Kataria, V., & Nair, A. Y. M. (2016) · Interventional Cardiology · doi:10.4172/ica.1000601
Nisbet, A. M., & Connelly, D. T. (2022) · Oxford University Press eBooks · doi:10.1093/med/9780198766223.003.0039
Liew, R. (2012) · Revista Portuguesa de Cardiologia (English Edition) · doi:10.1016/j.repce.2011.11.018
Management of ventricular arrhythmias in heart failure: current perspectives
Rafaj, A., Peichl, P., & Kautzner, J. (2022) · Intervenční a akutní kardiologie · doi:10.36290/kar.2022.019
The Sisyphean task of ventricular tachycardia mapping and ablation in structural heart disease
Lloyd, M. S., & Jain, V. (2023) · Kardiologia Polska · doi:10.33963/kp.a2023.0029
Filipovic, K., Sultan, A., van den Bruck, J., & Steven, D. (2023) · Kardiologie up2date · doi:10.1055/a-1476-9625
“Das gemeinsame Fazit der ersten 3 Studien war, dass eine präventive Ablation – d. h. eine Ablation bereits unmittelbar nach dem erstmaligen Auftreten einer VT vor einem möglichen Rezidiv – überlegt werden soll, da hierdurch zwar keine signifikante Letalitätsreduktion erzielt werden kann, jedoch das erneute Auftreten v…”
BackgroundInfluentialMyocardial infarction-related ventricular arrhythmias
Stoyanov, M. K., & Shalganov, T. N. (2023) · Bulgarian Cardiology · doi:10.3897/bgcardio.29.e101578
Novel use of an irrigated ablation catheter to monitor real‐time hemodynamics during ablation
Bhatia, N. K., Iravanian, S., Ravi, N., Kiani, S., Lloyd, M. S., Westerman, S. B., Merchant, F. M., El‐Chami, M. F., Hoque, A., & SHAH, A. D. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15902
Katheterablation ventrikulärer Tachykardien – eher früher als später?
Maagh, P., Perings, C., & Strickling, N. (2023) · Aktuelle Kardiologie · doi:10.1055/a-2023-2118
“V er vi el fä lti gu ng n ur m it Z us tim m un g de s V er la ge s. KURZGEFASST SMASH-VT, VTACH und SMS haben ergeben, dass eine frühe VT-Ablation nach dem ersten ICD-Schock oder schon zum Zeitpunkt der ICD-Implantation die VT-freie Zeit deutlich verlängern kann.”
BackgroundInfluentialVentrikuläre Herzrhythmusstörungen
Steven, D., Scheurlen, C., Dittrich, S., Filipovic, K., van den Bruck, J., & Sultan, A. (2022) · Springer Reference Medizin · doi:10.1007/978-3-662-62939-0_4-1
Metadata
- Authors
- Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E.
- Affiliations
- Massachusetts General Hospital (US)
- Beth Israel Deaconess Medical Center (US)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2007-12-27
- Volume
- 357
- Issue
- 26
- Pages
- 2657-2665
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- PMC
- PMC2390777
- OpenAlex
- W2139803224
- Cited by
- 959
- References
- 28
- Citations by year
- 2026: 39 · 2025: 42 · 2024: 47 · 2023: 43 · 2022: 53 · 2021: 45 · 2020: 54 · 2019: 62 · 2018: 53 · 2017: 63 · 2016: 40 · 2015: 59 · 2014: 46 · 2013: 56 · 2012: 48
- FWCI
- 33.47
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Heart, Lung, and Blood Institute (K23 HL 68064, K23HL077171, K23HL068064)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- implantable cardioverter-defibrillator, ventricular tachyarrhythmia, myocardial infarction, sudden cardiac death, radiofrequency ablation, substrate-based ablation, myocardial scar, ICD shocks, secondary prevention
- MeSH terms
- Aged, Electric Countershock, Female, Follow-Up Studies, Humans, Male, Middle Aged, Myocardial Infarction, Prospective Studies, Ventricular Fibrillation, Multivariate Analysis, Death, Sudden, Cardiac, Catheter Ablation, Defibrillators, Implantable, Tachycardia, Ventricular, Kaplan-Meier Estimate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.