The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Long-Term Safety and Efficacy of Drug-Eluting versus Bare-Metal Stents in Sweden
Open accessAbstract
BACKGROUND: The long-term safety and efficacy of drug-eluting coronary stents have been questioned. METHODS: We evaluated 47,967 patients in Sweden who received a coronary stent and were entered into the Swedish Coronary Angiography and Angioplasty Registry between 2003 and 2006 and for whom complete follow-up data were available for 1 to 5 years (mean, 2.7). In the primary analysis, we compared patients who received one drug-eluting coronary stent (10,294 patients) with those who received one bare-metal stent (18,659), after adjustment for differences in clinical characteristics of the patients and characteristics of the vessels and lesions. RESULTS: Analyses of outcome were based on 2380 deaths and 3198 myocardial infarctions. There was no overall difference between the group that received drug-eluting stents and the group that received bare-metal stents in the combined end point of death or myocardial infarction (relative risk with drug-eluting stents, 0.96; 95% confidence interval [CI], 0.89 to 1.03) or the individual end points of death (relative risk, 0.94; 95% CI, 0.85 to 1.05) and myocardial infarction (relative risk, 0.97; 95% CI, 0.88 to 1.06), and there was no significant difference in outcome among subgroups stratified according to the indication for stent implantation. Patients who received drug-eluting stents in 2003 had a significantly higher rate of late events than patients who received bare-metal stents in the same year, but we did not observe any difference in outcome among patients treated in later years. The average rate of restenosis during the first year was 3.0 events per 100 patient-years with drug-eluting stents versus 4.7 with bare-metal stents (adjusted relative risk, 0.43; 95% CI, 0.36 to 0.52); 39 patients would need to be treated with drug-eluting stents to prevent one case of restenosis. Among high-risk patients, the adjusted risk of restenosis was 74% lower with drug-eluting stents than with bare-metal stents, and only 10 lesions would need to be treated to prevent one case of restenosis. CONCLUSIONS: As compared with bare-metal stents, drug-eluting stents are associated with a similar long-term incidence of death or myocardial infarction and provide a clinically important decrease in the rate of restenosis among high-risk patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calculating the number needed to treat for trials where the outcome is time to an event
Altman, D. G., & Andersen, P. K. (1999) · BMJ · doi:10.1136/bmj.319.7223.1492 · Cited by 710
Effectiveness and Safety of Drug-Eluting Stents in Ontario
Tu, J. V., Bowen, J., Chiu, M., Ko, D. T., Austin, P. C., He, Y., Hopkins, R., Tarride, J.-E., Blackhouse, G., Lazzam, C., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071076 · Cited by 383
Cited by
Kolandaivelu, K., Swaminathan, R., Gibson, W. J., Kolachalama, V. B., Nguyen-Ehrenreich, K.-L., Giddings, V. L., Coleman, L., Wong, G. K., & Edelman, E. R. (2011) · Circulation · doi:10.1161/circulationaha.110.003210 · Cited by 802
Jernberg, T., Attebring, M. F., Hambraeus, K., Ivert, T., James, S., Jeppsson, A., Lagerqvist, B., Lindahl, B., Stenestrand, U., & Wallentin, L. (2010) · Heart · doi:10.1136/hrt.2010.198804 · Cited by 773
Self-citationGarg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Role of Endothelial Shear Stress in Stent Restenosis and Thrombosis
Koskinas, K. C., Chatzizisis, Y. S., Antoniadis, A. P., & Giannoglou, G. D. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.10.903 · Cited by 347
Registry-based randomized clinical trials—a new clinical trial paradigm
James, S., Rao, S. V., & Granger, C. B. (2015) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2015.33 · Cited by 331
Self-citationRedfors, B., Vedad, R., Angerås, O., Råmunddal, T., Petursson, P., Haraldsson, I., Ali, A., Dworeck, C., Odenstedt, J., Ioaness, D., et al. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.03.162 · Cited by 324
Gender differences in the effects of cardiovascular drugs
Tamargo, J., Rosano, G., Walther, T., Duarte, J., Niessner, A., Kaski, J., Ceconi, C., Drexel, H., Kjeldsen, K., Savarese, G., et al. (2017) · European Heart Journal - Cardiovascular Pharmacotherapy · doi:10.1093/ehjcvp/pvw042 · Cited by 317
Metadata
- Authors
- James, S. K., Stenestrand, U., Lindbäck, J., Carlsson, J., Scherstén, F., Nilsson, T., Wallentin, L., & Lagerqvist, B.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2009-05-07
- Volume
- 360
- Issue
- 19
- Pages
- 1933-1945
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2142075142
- Cited by
- 237
- References
- 2
- FWCI
- 35.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.