Extended-Release Niacin or Ezetimibe and Carotid Intima–Media Thickness

Taylor, Allen J., Villines, Todd C., Stanek, Eric J., Devine, Patrick J., Griffen, Len, Miller, Michael, Weissman, Neil J., Turco, Mark·2009·New England Journal of Medicine

Abstract

BACKGROUND: Treatment added to statin monotherapy to further modify the lipid profile may include combination therapy to either raise the high-density lipoprotein (HDL) cholesterol level or further lower the low-density lipoprotein (LDL) cholesterol level. METHODS: We enrolled patients who had coronary heart disease or a coronary heart disease risk equivalent, who were receiving long-term statin therapy, and in whom an LDL cholesterol level under 100 mg per deciliter (2.6 mmol per liter) and an HDL cholesterol level under 50 mg per deciliter for men or 55 mg per deciliter for women (1.3 or 1.4 mmol per liter, respectively) had been achieved. The patients were randomly assigned to receive extended-release niacin (target dose, 2000 mg per day) or ezetimibe (10 mg per day). The primary end point was the between-group difference in the change from baseline in the mean common carotid intima-media thickness after 14 months. The trial was terminated early, on the basis of efficacy, according to a prespecified analysis conducted after 208 patients had completed the trial. RESULTS: The mean HDL cholesterol level in the niacin group increased by 18.4% over the 14-month study period, to 50 mg per deciliter (P < 0.001), and the mean LDL cholesterol level in the ezetimibe group decreased by 19.2%, to 66 mg per deciliter (1.7 mmol per liter) (P < 0.001). Niacin therapy significantly reduced LDL cholesterol and triglyceride levels; ezetimibe reduced the HDL cholesterol and triglyceride levels. As compared with ezetimibe, niacin had greater efficacy regarding the change in mean carotid intima-media thickness over 14 months (P = 0.003), leading to significant reduction of both mean (P = 0.001) and maximal carotid intima-media thickness (P < or = 0.001 for all comparisons). Paradoxically, greater reductions in the LDL cholesterol level in association with ezetimibe were significantly associated with an increase in the carotid intima-media thickness (R = -0.31, P < 0.001). The incidence of major cardiovascular events was lower in the niacin group than in the ezetimibe group (1% vs. 5%, P = 0.04 by the chi-square test). CONCLUSIONS: This comparative-effectiveness trial shows that the use of extended-release niacin causes a significant regression of carotid intima-media thickness when combined with a statin and that niacin is superior to ezetimibe. (ClinicalTrials.gov number, NCT00397657.)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa0907569

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 644

Metadata

Authors
Taylor, A. J., Villines, T. C., Stanek, E. J., Devine, P. J., Griffen, L., Miller, M., Weissman, N. J., & Turco, M.
Venue
New England Journal of Medicine
Published
2009-11-26
Volume
361
Issue
22
Pages
2113-2122
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2101969945
Cited by
644
References
11
FWCI
120.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Extended-Release Niacin or Ezetimibe and Carotid Intima–Media Thickness. https://app.cochat.ai/papers/10.1056/nejmoa0907569
The paper
Taylor, A. J., Villines, T. C., Stanek, E. J., Devine, P. J., Griffen, L., Miller, M., Weissman, N. J., & Turco, M. (2009). Extended-Release Niacin or Ezetimibe and Carotid Intima–Media Thickness. New England Journal of Medicine. https://doi.org/10.1056/nejmoa0907569

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.