The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Closed-Loop Insulin Delivery for Glycemic Control in Noncritical Care
Open accessAbstract
BACKGROUND: In patients with diabetes, hospitalization can complicate the achievement of recommended glycemic targets. There is increasing evidence that a closed-loop delivery system (artificial pancreas) can improve glucose control in patients with type 1 diabetes. We wanted to investigate whether a closed-loop system could also improve glycemic control in patients with type 2 diabetes who were receiving noncritical care. METHODS: In this randomized, open-label trial conducted on general wards in two tertiary hospitals located in the United Kingdom and Switzerland, we assigned 136 adults with type 2 diabetes who required subcutaneous insulin therapy to receive either closed-loop insulin delivery (70 patients) or conventional subcutaneous insulin therapy, according to local clinical practice (66 patients). The primary end point was the percentage of time that the sensor glucose measurement was within the target range of 100 to 180 mg per deciliter (5.6 to 10.0 mmol per liter) for up to 15 days or until hospital discharge. RESULTS: The mean (±SD) percentage of time that the sensor glucose measurement was in the target range was 65.8±16.8% in the closed-loop group and 41.5±16.9% in the control group, a difference of 24.3±2.9 percentage points (95% confidence interval [CI], 18.6 to 30.0; P<0.001); values above the target range were found in 23.6±16.6% and 49.5±22.8% of the patients, respectively, a difference of 25.9±3.4 percentage points (95% CI, 19.2 to 32.7; P<0.001). The mean glucose level was 154 mg per deciliter (8.5 mmol per liter) in the closed-loop group and 188 mg per deciliter (10.4 mmol per liter) in the control group (P<0.001). There was no significant between-group difference in the duration of hypoglycemia (as defined by a sensor glucose measurement of <54 mg per deciliter; P=0.80) or in the amount of insulin that was delivered (median dose, 44.4 U and 40.2 U, respectively; P=0.50). No episode of severe hypoglycemia or clinically significant hyperglycemia with ketonemia occurred in either trial group. CONCLUSIONS: Among inpatients with type 2 diabetes receiving noncritical care, the use of an automated, closed-loop insulin-delivery system resulted in significantly better glycemic control than conventional subcutaneous insulin therapy, without a higher risk of hypoglycemia. (Funded by Diabetes UK and others; ClinicalTrials.gov number, NCT01774565 .).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In a randomized controlled trial, people with type 2 diabetes receiving noncritical care had significantly better glycemia with the use of an automated, fully closed-loop insulin delivery system than with conventional subcutaneous insulin therapy, without a higher risk of hypoglycemia (59).”
From 16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2026 (2026) · cites this paper as [59]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charlson, M. E., Pompei, P., Ales, K. L., & MacKenzie, C. R. (1987) · Journal of Chronic Diseases · doi:10.1016/0021-9681(87)90171-8 · Cited by 49,742
International Diabetes Federation 2017
Carracher, A. M., Marathe, P. H., & Close, K. L. (2018) · Journal of Diabetes · doi:10.1111/1753-0407.12644 · Cited by 13,379
Hyperglycemia: an independent marker of in-hospital mortality in patients with undiagnosed diabetes
Umpierrez, G. E., Isaacs, S. D., Bazargan, N., You, X., Thaler, L. M., & Kitabchi, A. E. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.3.8341 · Cited by 2,195
Dungan, K. M., Braithwaite, S. S., & Preiser, J.-C. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60553-5 · Cited by 1,431
Umpierrez, G. E., Hellman, R., Korytkowski, M. T., Kosiborod, M., Maynard, G. A., Montori, V. M., Seley, J. J., & Van den Berghe, G. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-2098 · Cited by 1,126
Discharge planning from hospital to home
Shepperd, S., Lannin, N. A., Clemson, L. M., McCluskey, A., Cameron, I. D., & Barras, S. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000313.pub4 · Cited by 936
Umpierrez, G. E., Smiley, D., Jacobs, S., Peng, L., Temponi, A., Mulligan, P., Umpierrez, D., Newton, C., Olson, D., & Rizzo, M. (2011) · Diabetes Care · doi:10.2337/dc10-1407 · Cited by 720
Home Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450
Self-citationBekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
Self-citationSteroid‐induced diabetes: a clinical and molecular approach to understanding and treatment
Hwang, J. L., & Weiss, R. E. (2013) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2486 · Cited by 399
Cited by
Sorted by citations
Items 201–231 of 231
Schaarup, J. R., Aggarwal, R., Dalsgaard, E., Norman, K., Dollerup, O. L., Ashrafian, H., Witte, D. R., Sandbæk, A., & Hulmán, Á. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4181697
Moon, S. J., Hong, J. H., Kim, S. S., Kim, K., Lim, S. K., Jin, H. Y., Hwang, Y., Lee, S., Lee, K., Kang, J. G., et al. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4608008
Fully automated insulin delivery: artificial pancreas
Barkai, L. (2023) · Egészségtudományi Közlemények · doi:10.32967/etk.2023.009
The History of Inpatient Diabetes
Brooks, D., Schulman‐Rosenbaum, R., Galindo, R. J., & Umpierrez, G. E. (2023) · Contemporary Endocrinology · doi:10.1007/978-3-031-44648-1_1
Chappel, E. (2024) · Encyclopedia · doi:10.3390/encyclopedia4020052
Advanced hybrid closed loop (artificial pancreas) and carbohydrate count in type 1 diabetes
Pollakova, D., Pantano, A. L., Folco, U. D., Nardone, M. R., & Tubili, C. (2024) · Mediterranean Journal of Nutrition and Metabolism · doi:10.3233/mnm-230125 · Cited by 1
Troubles glycémiques postopératoires
Besch, G. (2024) · Elsevier eBooks · doi:10.1016/b978-2-294-78187-2.00049-2
李, 康. (2024) · Journal of Clinical Personalized Medicine · doi:10.12677/jcpm.2024.34367
Krutkyte, G., Banholzer, N., Herzig, D., & Bally, L. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0248
Self-citationNamasivayam, A., Walton-Betancourth, S., Hysted, H., Datta, V., Myles, C., Boughton, C. K., Marcovecchio, M. L., & Thankamony, A. (2025) · Annals of Pediatric Endocrinology & Metabolism · doi:10.6065/apem.2448150.075
Bioelectronic Devices for Diabetes: Monitoring, Management, and Precision Health
Mahato, K., & Kummari, S. (2025) · Springer eBooks · doi:10.1007/978-981-95-2117-3_8
Jiang, H., Henley, D., & Jiang, F. (2025) · World Journal of Transplantation · doi:10.5500/wjt.v15.i4.101926
Histoire, actualités et perspectives du pancréas artificiel
Hanaire, H. P. (2025) · Bulletin de l Académie Nationale de Médecine · doi:10.1016/j.banm.2025.10.013
Graña, C., Ravaud, P., Ghosn, L., & Tran, V.-T. (2020) · Figshare · doi:10.6084/m9.figshare.13199052
Insulin pumps and artificial pancreas
Markakis, K. P., & Vazeou, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13825-6.00296-x
Insulin Pump Therapy in the Hospital
Thompson, B., Boyle, M. E., & Cook, C. B. (2025) · Medical Clinics of North America · doi:10.1016/j.mcna.2025.11.009
Müssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2026) · Die Diabetologie · doi:10.1007/s11428-026-01424-3
Mise au point sur l’utilisation de l’insulinothérapie automatisée pour traiter le diabète de type 2
Reznik, Y. (2026) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2026.01.011
Vaughan, N., & Rashid, A. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106361
Automated Insulin Delivery for Patients with Type 2 Diabetes: A Narrative Review
Kitsios, K., & Trakatelli, C. (2026) · Current Diabetes Reviews · doi:10.2174/0115733998418695251203105337 · Cited by 1
Tejera-Perez, C., Hernández-Olmeda, F., de Villar, N. G. P., & Tejera-Perez, R. (2026) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-026-10032-x
In Vitro and in Silico approach of continuous subcutaneous insulin infusion system reliability
Girardot, S. (2020) · theses.fr (ABES) · doi:10.70675/4f3118b9zebc2z40b9z9baczafa4dd39494c
Automated insulin delivery in type 2 diabetes: a meta-analysis of randomized trials protocol
Gordillo-Rosas, L., Cajachagua-Pucuhuaranga, C. L., Cruz-Venegas, J. A. S., Urrutia-Osorio, L. M., Meneses, S. A. P., Lozano-Núñez, J., Rivera-Lozada, O., Bonilla-Asalde, C., & Barboza, J. J. (2026) · Systematic Reviews · doi:10.1186/s13643-026-03206-w
Cunningham, H., Jenkins, A., O'Neal, D. N., & Lee, M. H. (2026) · Diabetic Medicine · doi:10.1111/dme.70372
Amouyal, C., Benhamou, P., Carlier, A., Marchand, L., Smati, S., & Villard, O. (2026) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2026.06.008
From algorithm to alarm: a narrative review on insulin delivery innovation
Saleem, N. U. A., Arshad, F., Qadri, M., Mushtaq, M. S., Khan, M., Shakoor, P., Patel, T., Noor, A., Sardarova, N., Anand, N., et al. (2026) · Annals of Medicine and Surgery · doi:10.1097/ms9.0000000000005307
Serafin, A., Kołodziej, A., Skalska, M., Wojtachnio, N., Strzyż, J., Rymska, K., & Starczyk, Z. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.2(50).2026.5362
Real-World Outcomes of Automated Insulin Delivery Use in Hospitalized Adults With Diabetes
Ruddiman, K. R., Evans, J. K., Aloi, J., Usoh, C. O., & Price, C. E. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261473583
Zhong, J., Zhao, C., Xu, S., Wang, H., Qi, R., Yang, S., & Cheng, L. (2026) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2026.113519
Olsen, M. T., Spanakis, E. K., Thabit, H., Dhatariya, K., Mustafa, O. G., Avari, P., Lumb, A. N., Dungan, K. M., Philis‐Tsimikas, A., Kulasa, K. M., et al. (2026) · Diabetologia · doi:10.1007/s00125-026-06838-8
Self-citationDiabetes im Krankenhaus – Praxisempfehlung der DDG
Müssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2026) · Diabetologie und Stoffwechsel · doi:10.1055/a-2884-3481
Metadata
- Authors
- Bally, L., Thabit, H., Hartnell, S., Andereggen, E., Ruan, Y., Wilinska, M. E., Evans, M. L., Wertli, M. M., Coll, A. P., Stettler, C., & Hovorka, R.
- Affiliations
- University of Bern (CH)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2018-08-09
- Volume
- 379
- Issue
- 6
- Pages
- 547-556
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2810166631
- Cited by
- 232
- References
- 27
- Citations by year
- 2026: 21 · 2025: 27 · 2024: 29 · 2023: 24 · 2022: 21 · 2021: 22 · 2020: 37 · 2019: 41 · 2018: 9
- FWCI
- 21.84
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (publishedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, other-oa)
- Bern Open Repository and Information System (University of Bern) (submittedVersion)
- Apollo (University of Cambridge) (submittedVersion)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion, other-oa)
- Apollo
- Zurich Open Repository and Archive (University of Zurich)
- Funders
- Diabetes UK (14/0004878)
- European Foundation for the Study of Diabetes
- Universität Bern
- Swiss Diabetes Foundation
- University Hospital Bern
- National Institute for Health Research Cambridge Biomedical Research Centre and Wellcome Strategic Award (100574/Z/12/Z)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (P1BEP3_165297)
- JDRF
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- artificial pancreas, type 2 diabetes, glycemic control, subcutaneous insulin therapy, continuous glucose monitoring, hypoglycemia, hyperglycemia, hospitalization, glycemic targets, insulin dose, general ward patients
- MeSH terms
- Aged, Blood Glucose, Diabetes Mellitus, Type 2, Female, Hospitalization, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Middle Aged, Pancreas, Artificial, Infusions, Subcutaneous
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review