Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 348

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Artificial Intelligence to Detect Papilledema from Ocular Fundus Photographs

Open access
Milea, Dan, Najjar, Raymond P., Jiang, Zhubo, Ting, Daniel, Vasseneix, Caroline, Xu, Xinxing, Aghsaei Fard, Masoud, Fonseca, Pedro, Vanikieti, Kavin, Lagrèze, Wolf A., La Morgia, Chiara, Cheung, Carol Y., Hamann, Steffen, Chiquet, Christophe, Sanda, Nicolae, Yang, Hui, Mejico, Luis J., Rougier, Marie-Bénédicte, Kho, Richard, Tran, Thi H.C., Singhal, Shweta, Gohier, Philippe, Clermont-Vignal, Catherine, Cheng, Ching-Yu, Jonas, Jost B., Yu-Wai-Man, Patrick, Fraser, Clare L., Chen, John J., Ambika, Selvakumar, Miller, Neil R., Liu, Yong, Newman, Nancy J., Wong, Tien Y., Biousse, Valérie·2020·New England Journal of Medicine

Abstract

BACKGROUND: Nonophthalmologist physicians do not confidently perform direct ophthalmoscopy. The use of artificial intelligence to detect papilledema and other optic-disk abnormalities from fundus photographs has not been well studied. METHODS: We trained, validated, and externally tested a deep-learning system to classify optic disks as being normal or having papilledema or other abnormalities from 15,846 retrospectively collected ocular fundus photographs that had been obtained with pharmacologic pupillary dilation and various digital cameras in persons from multiple ethnic populations. Of these photographs, 14,341 from 19 sites in 11 countries were used for training and validation, and 1505 photographs from 5 other sites were used for external testing. Performance at classifying the optic-disk appearance was evaluated by calculating the area under the receiver-operating-characteristic curve (AUC), sensitivity, and specificity, as compared with a reference standard of clinical diagnoses by neuro-ophthalmologists. RESULTS: The training and validation data sets from 6779 patients included 14,341 photographs: 9156 of normal disks, 2148 of disks with papilledema, and 3037 of disks with other abnormalities. The percentage classified as being normal ranged across sites from 9.8 to 100%; the percentage classified as having papilledema ranged across sites from zero to 59.5%. In the validation set, the system discriminated disks with papilledema from normal disks and disks with nonpapilledema abnormalities with an AUC of 0.99 (95% confidence interval [CI], 0.98 to 0.99) and normal from abnormal disks with an AUC of 0.99 (95% CI, 0.99 to 0.99). In the external-testing data set of 1505 photographs, the system had an AUC for the detection of papilledema of 0.96 (95% CI, 0.95 to 0.97), a sensitivity of 96.4% (95% CI, 93.9 to 98.3), and a specificity of 84.7% (95% CI, 82.3 to 87.1). CONCLUSIONS: A deep-learning system using fundus photographs with pharmacologically dilated pupils differentiated among optic disks with papilledema, normal disks, and disks with nonpapilledema abnormalities. (Funded by the Singapore National Medical Research Council and the SingHealth Duke-NUS Ophthalmology and Visual Sciences Academic Clinical Program.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1917130

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 348

Metadata

Authors
Milea, D., Najjar, R. P., Jiang, Z., Ting, D., Vasseneix, C., Xu, X., Aghsaei Fard, M., Fonseca, P., Vanikieti, K., Lagrèze, W. A., La Morgia, C., Cheung, C. Y., Hamann, S., Chiquet, C., Sanda, N., Yang, H., Mejico, L. J., Rougier, M.-B., Kho, R., Tran, T. H. C., Singhal, S., Gohier, P., Clermont-Vignal, C., Cheng, C.-Y., Jonas, J. B., Yu-Wai-Man, P., Fraser, C. L., Chen, J. J., Ambika, S., Miller, N. R., Liu, Y., Newman, N. J., Wong, T. Y., & Biousse, V.
Venue
New England Journal of Medicine
Published
2020-04-30
Volume
382
Issue
18
Pages
1687-1695
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W3015487562
Cited by
348
References
27
FWCI
21.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Intelligence to Detect Papilledema from Ocular Fundus Photographs. https://app.cochat.ai/papers/10.1056/nejmoa1917130
The paper
Milea, D., Najjar, R. P., Jiang, Z., Ting, D., Vasseneix, C., Xu, X., Aghsaei Fard, M., Fonseca, P., Vanikieti, K., Lagrèze, W. A., La Morgia, C., Cheung, C. Y., Hamann, S., Chiquet, C., Sanda, N., Yang, H., Mejico, L. J., Rougier, M.-B., Kho, R., . . . Biousse, V. (2020). Artificial Intelligence to Detect Papilledema from Ocular Fundus Photographs. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1917130

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.