The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Cryoballoon Ablation as Initial Therapy for Atrial Fibrillation
Open accessAbstract
BACKGROUND: In patients with symptomatic paroxysmal atrial fibrillation that has not responded to medication, catheter ablation is more effective than antiarrhythmic drug therapy for maintaining sinus rhythm. However, the safety and efficacy of cryoballoon ablation as initial first-line therapy have not been established. METHODS: We performed a multicenter trial in which patients 18 to 80 years of age who had paroxysmal atrial fibrillation for which they had not previously received rhythm-control therapy were randomly assigned (1:1) to receive treatment with antiarrhythmic drugs (class I or III agents) or pulmonary vein isolation with a cryoballoon. Arrhythmia monitoring included 12-lead electrocardiography conducted at baseline and at 1, 3, 6, and 12 months; patient-activated telephone monitoring conducted weekly and when symptoms were present during months 3 through 12; and 24-hour ambulatory monitoring conducted at 6 and 12 months. The primary efficacy end point was treatment success (defined as freedom from initial failure of the procedure or atrial arrhythmia recurrence after a 90-day blanking period to allow recovery from the procedure or drug dose adjustment, evaluated in a Kaplan-Meier analysis). The primary safety end point was assessed in the ablation group only and was a composite of several procedure-related and cryoballoon system-related serious adverse events. RESULTS: Of the 203 participants who underwent randomization and received treatment, 104 underwent ablation, and 99 initially received drug therapy. In the ablation group, initial success of the procedure was achieved in 97% of patients. The Kaplan-Meier estimate of the percentage of patients with treatment success at 12 months was 74.6% (95% confidence interval [CI], 65.0 to 82.0) in the ablation group and 45.0% (95% CI, 34.6 to 54.7) in the drug-therapy group (P<0.001 by log-rank test). Two primary safety end-point events occurred in the ablation group (Kaplan-Meier estimate of the percentage of patients with an event within 12 months, 1.9%; 95% CI, 0.5 to 7.5). CONCLUSIONS: Cryoballoon ablation as initial therapy was superior to drug therapy for the prevention of atrial arrhythmia recurrence in patients with paroxysmal atrial fibrillation. Serious procedure-related adverse events were uncommon. (Supported by Medtronic; STOP AF First ClinicalTrials.gov number, NCT03118518.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Early Rhythm-Control Therapy in Patients with Atrial Fibrillation
Kirchhof, P., Camm, A. J., Goette, A., Brandes, A., Eckardt, L., Elvan, A., Fetsch, T., van Gelder, I. C., Haase, D., Haegeli, L. M., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2019422 · Cited by 2,190
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602014 · Cited by 1,950
Packer, D. L., Mark, D. B., Robb, R. A., Monahan, K. H., Bahnson, T. D., Poole, J. E., Noseworthy, P. A., Rosenberg, Y. D., Jeffries, N., Mitchell, L. B., et al. (2019) · JAMA · doi:10.1001/jama.2019.0693 · Cited by 1,503
THE COMPARISON OF PERCENTAGES IN MATCHED SAMPLES
COCHRAN, W. G. (1950) · Biometrika · doi:10.1093/biomet/37.3-4.256 · Cited by 1,465
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Wazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., et al. (2005) · JAMA · doi:10.1001/jama.293.21.2634 · Cited by 1,121
Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial Fibrillation
Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., Dubuc, M., Reddy, V., Nelson, L., Holcomb, R. G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.064 · Cited by 899
Radiofrequency ablation as initial therapy in paroxysmal atrial fibrillation
Cosedis Nielsen, J., Johannessen, A., Raatikainen, P., Hindricks, G., Walfridsson, H., Kongstad, O., Pehrson, S., Englund, A., Hartikainen, J., Mortensen, L. S., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113566 · Cited by 720
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation
Reddy, V. Y., Gerstenfeld, E. P., Natale, A., Whang, W., Cuoco, F. A., Patel, C., Mountantonakis, S. E., Gibson, D. N., Harding, J. D., Ellis, C. R., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2307291 · Cited by 970
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Metadata
- Authors
- Wazni, O. M., Dandamudi, G., Sood, N., Hoyt, R., Tyler, J., Durrani, S., Niebauer, M., Makati, K., Halperin, B., Gauri, A., Morales, G., Shao, M., Cerkvenik, J., Kaplon, R. E., & Nissen, S. E.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2021-01-28
- Volume
- 384
- Issue
- 4
- Pages
- 316-324
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W3100870347
- Cited by
- 649
- References
- 27
- FWCI
- 48.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cryoballoon Ablation as Initial Therapy for Atrial Fibrillation. https://app.cochat.ai/papers/10.1056/nejmoa2029554
- The paper
- Wazni, O. M., Dandamudi, G., Sood, N., Hoyt, R., Tyler, J., Durrani, S., Niebauer, M., Makati, K., Halperin, B., Gauri, A., Morales, G., Shao, M., Cerkvenik, J., Kaplon, R. E., & Nissen, S. E. (2021). Cryoballoon Ablation as Initial Therapy for Atrial Fibrillation. New England Journal of Medicine. https://doi.org/10.1056/nejmoa2029554
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.