Pulsed Field or Cryoballoon Ablation for Paroxysmal Atrial Fibrillation
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Pulmonary-vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation (PFA) is a nonthermal ablation method with few adverse effects beyond the myocardium. Data are lacking on outcomes after PFA as compared with cryoballoon ablation as assessed with continuous rhythm monitoring. METHODS: In this randomized noninferiority trial in Switzerland, we randomly assigned patients with symptomatic paroxysmal atrial fibrillation in a 1:1 ratio to undergo PFA or cryoablation. All the patients received an implantable cardiac monitor to detect atrial tachyarrhythmias. The primary end point was the first recurrence of an atrial tachyarrhythmia between day 91 and day 365 after ablation. We assessed noninferiority using a margin of 20 percentage points for the difference in the cumulative incidence of recurrence. The safety end point was a composite of procedure-related complications. RESULTS: A total of 105 patients were assigned to undergo PFA, and 105 were assigned to undergo cryoablation. A recurrence of atrial tachyarrhythmia was observed between day 91 and day 365 in 39 patients in the PFA group and in 53 patients in the cryoablation group (Kaplan-Meier cumulative incidence, 37.1% and 50.7%, respectively; between-group difference, -13.6 percentage points; 95% confidence interval, -26.9 to -0.3; P<0.001 for noninferiority, P = 0.046 for superiority). The safety end point occurred in 1 patient (1.0%) with PFA and in 2 patients (1.9%) with cryoablation. CONCLUSIONS: Among patients with symptomatic paroxysmal atrial fibrillation, PFA was noninferior to cryoballoon ablation with respect to the incidence of a first recurrence of atrial tachyarrhythmia, as assessed by continuous rhythm monitoring. (Funded by Inselspital and others; SINGLE SHOT CHAMPION ClinicalTrials.gov number, NCT05534581.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Self-citationCryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602014 · Cited by 1,950
Wilber, D. J., Pappone, C., Neuzil, P., De Paola, A., Marchlinski, F., Natale, A., Macle, L., Daoud, E. G., Calkins, H., Hall, B., et al. (2010) · JAMA · doi:10.1001/jama.2009.2029 · Cited by 1,170
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Sanders, P., Pürerfellner, H., Pokushalov, E., Sarkar, S., Di Bacco, M., Maus, B., & Dekker, L. R. C. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.03.005 · Cited by 162
Metadata
- Authors
- Reichlin, T., Kueffer, T., Badertscher, P., Jüni, P., Knecht, S., Thalmann, G., Kozhuharov, N., Krisai, P., Jufer, C., Maurhofer, J., Heg, D., Pereira, T. V., Mahfoud, F., Servatius, H., Tanner, H., Kühne, M., Roten, L., & Sticherling, C.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2025-04-17
- Volume
- 392
- Issue
- 15
- Pages
- 1497-1507
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W4409000727
- Cited by
- 225
- References
- 5
- FWCI
- 143.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.