Control of Along‐Wind Response of Structures by Mass and Liquid Dampers
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
An investigation is made of the possible application of tuned liquid column dampers and tuned liquid column/mass dampers in reducing the along‐wind response of wind‐sensitive structures. The structure is modeled as a lumped mass multi‐degree‐of‐freedom system taking into account both bending and shear. The wind turbulence is mqdeled as a stochastic process that is stationary in time and nonhomogeneous in space. A random vibration analysis utilizing transfer matrix formulation is carried out to obtain response statistics. The nonlinear damping term in the fundamental equation of the tuned liquid damper is treated by an equivalent linearization technique. Numerical examples show that tuned liquid dampers, which have significant practical advantages, are as effective as the traditional tuned mass dampers if the parameters of the liquid dampers are properly selected. However, excess liquid motion in a tuned liquid column/mass damper may reduce the effectiveness of this damper. It is also shown that the wind‐induced force‐ and acceleration‐type responses of the structure with a damper, which is usually tuned to the fundamental frequency of the structure, should involve more than one vibration mode as higher‐mode responses may become as large or even larger than the controlled‐mode response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Equivalent Linearization for Hysteretic Systems Under Random Excitation
Wen, Y. K. (1980) · Journal of Applied Mechanics · doi:10.1115/1.3153594 · Cited by 562
Application of Statistical Linearization Techniques to Nonlinear Multidegree-of-Freedom Systems
Iwan, W. D., & Yang, I.-M. (1972) · Journal of Applied Mechanics · doi:10.1115/1.3422714 · Cited by 146
Fujino, Y., Pacheco, B. M., Chaiseri, P., & Li Min, S. U. N. (1988) · Doboku Gakkai Ronbunshu · doi:10.2208/jscej.1988.398_177 · Cited by 111
Damping Increase in Building with Tuned Mass Damper
Kwok, K. C. S. (1984) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1984)110:11(1645 · Cited by 76
Self-citation
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Tuned liquid column dampers in offshore wind turbines for structural control
Colwell, S., & Basu, B. (2009) · Engineering Structures · doi:10.1016/j.engstruct.2008.09.001 · Cited by 406
Optimization of tuned liquid column dampers
Gao, H., Kwok, K. C. S., & Samali, B. (1997) · Engineering Structures · doi:10.1016/s0141-0296(96)00099-5 · Cited by 289
Self-citationOptimum Absorber Parameters for Tuned Liquid Column Dampers
Yalla, S. K., & Kareem, A. (2000) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2000)126:8(906 · Cited by 224
Performance of tuned mass dampers under wind loads
Kwok, K. C. S., & Samali, B. (1995) · Engineering Structures · doi:10.1016/0141-0296(95)00035-6 · Cited by 206
Self-citationCharacteristics of liquid column vibration absorbers (LCVA)—I
Hitchcock, P. A., Kwok, K. C. S., Watkins, R. D., & Samali, B. (1997) · Engineering Structures · doi:10.1016/s0141-0296(96)00042-9 · Cited by 183
Self-citationEffectiveness of tuned liquid column dampers for vibration control of towers
Balendra, T., Wang, C. M., & Cheong, H. F. (1995) · Engineering Structures · doi:10.1016/0141-0296(95)00036-7 · Cited by 178
Semi-active tuned liquid column dampers for vibration control of structures
Yalla, S. K., Kareem, A., & Kantor, J. C. (2001) · Engineering Structures · doi:10.1016/s0141-0296(01)00047-5 · Cited by 164
“Subsequent numerical studies found TLCDs to be effective for wind and earthquake loading [9,10].”
BackgroundControl of flutter of suspension bridge deck using TMD
Pourzeynali, S., & Datta, T. K. (2002) · Wind and Structures · doi:10.12989/was.2002.5.5.407 · Cited by 45
Min, K.-W., Kim, J., & Lee, H.-R. (2014) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2014.03.003 · Cited by 38
Ueng, J., Lin, C., & Wang, J. (2008) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.336 · Cited by 36
Ruiz, R. O., Taflanidis, A. A., & Lopez-Garcia, D. (2016) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.01.014 · Cited by 32
Compliant liquid column damper modified by shape memory alloy device for seismic vibration control
Gur, S., Mishra, S. K., Bhowmick, S., & Chakraborty, S. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/10/105009 · Cited by 30
Structural Control: Past, Present, and Future
(1997) · doi:10.1061/(asce)0733-9399(1997)123:9(897
Metadata
- Authors
- Xu, Y. L., Samali, B., & Kwok, K. C. S.
- Venue
- Journal of Engineering Mechanics
- Published
- 1992-01
- Volume
- 118
- Issue
- 1
- Pages
- 20-39
- ISSN
- 0733-9399 (ISSN-L)
- 1943-7889
- DOI
- 10.1061/(asce)0733-9399(1992)118:1(20
- OpenAlex
- W2046122403
- Cited by
- 189
- References
- 4
- FWCI
- 9.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.