Benchmark Problem for Response Control of Wind-Excited Tall Buildings
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
This paper presents an overview and problem definition of a benchmark problem for the response control of wind-excited tall buildings. The building considered is a 76-story 306 m concrete office tower proposed for the city of Melbourne, Australia. The building is slender with a height to width ratio of 7.3; hence, it is wind sensitive. Wind tunnel tests for such a 76-story building model have been conducted at the University of Sydney and the results of across-wind data are used in the present benchmark problem. Either active, semiactive, or passive control systems can be installed in the building to reduce the wind response, although only an active control sample problem has been worked out to illustrate the control design. In the case of active control systems, either an active tuned mass damper or an active mass driver can be installed on the top floor. In the case of passive or semiactive systems, such as viscous dampers, viscoelastic dampers, electrorheological, or magnetorheological dampers, etc., control devices can be installed in selected story units. Control constraints and evaluation criteria are presented for the design problem. A simulation program based on the linear quadratic Gaussian technique has been developed and made available for the comparison of the performance of various control strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wind Effects on Structures: Modern Structural Design for Wind
Simiu, E., & Yeo, D. (2019) · Cited by 1,048
A method for simplifying linear dynamic systems
Davison, E. (1966) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1966.1098264 · Cited by 633
Role of Control-Structure Interaction in Protective System Design
Dyke, S. J., Spencer, B. F., Quast, P., & Sain, M. K. (1995) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1995)121:2(322 · Cited by 329
Benchmark problems in structural control: part I—Active Mass Driver system
Spencer, B. F., Dyke, S. J., & Deoskar, H. S. (1998) · Earthquake Engineering & Structural Dynamics · doi:10.1002/(sici)1096-9845(1998110)27:11<1127::aid-eqe774>3.0.co;2-f · Cited by 270
Dynamic Systems Control: Linear Systems Analysis and Synthesis
Skelton, R. E. (1988) · Cited by 212
Simple ATMD Control Methodology for Tall Buildings Subject to Wind Loads
Ankireddi, S., & Y. Yang, H. T. (1996) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1996)122:1(83 · Cited by 129
Design of an active mass damper for a tall TV tower in Nanjing, China
Cao, H., Reinhorn, A. M., & Soong, T. T. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00072-2 · Cited by 114
Frequency Domain Optimal Control of Wind‐Excited Buildings
Suhardjo, J., Spencer, B. F., & Kareem, A. (1992) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1992)118:12(2463 · Cited by 95
Reduced-order H∞ and LQR control for wind-excited tall buildings
Wu, J., Yang, J. N., & Schmitendorf, W. E. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00081-3 · Cited by 86
Self-citationWind Tunnel Tests for Wind-Excited Benchmark Building
Samali, B., Kwok, K. C. S., Wood, G. S., & Yang, J. (2004) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(2004)130:4(447 · Cited by 76
Self-citationControl of Tall Buildings in Along‐Wind Motion
Yang, J. N., & Samali, B. (1983) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1983)109:1(50 · Cited by 51
Self-citationActive Control of Transmission Tower under Stochastic Wind
Wu, J. C., & Yang, J. N. (1998) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1998)124:11(1302 · Cited by 51
Self-citationLQG control of lateral-torsional motion of Nanjing TV transmission tower
Wu, J., & Yang, J. N. (2000) · Earthquake Engineering & Structural Dynamics · doi:10.1002/1096-9845(200008)29:8<1111::aid-eqe957>3.0.co;2-r · Cited by 44
Self-citation(2004) · doi:10.1061/(asce)0733-9399(2004)130:4(366
Cited by
Immersed boundary methods for simulating fluid–structure interaction
Sotiropoulos, F., & Yang, X. (2014) · Progress in Aerospace Sciences · doi:10.1016/j.paerosci.2013.09.003 · Cited by 473
Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
Giaralis, A., & Petrini, F. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001863 · Cited by 330
Nagarajaiah, S., & Varadarajan, N. (2005) · Engineering Structures · doi:10.1016/j.engstruct.2004.10.015 · Cited by 212
“[25,27] is considered as the numerical example.”
BackgroundInfluentialSmart structures: Part II — Hybrid control systems and control strategies
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.035 · Cited by 177
Dai, J., Xu, Z.-D., & Gai, P.-P. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2019.109585 · Cited by 163
Metadata
- Authors
- Yang, J. N., Agrawal, A. K., Samali, B., & Wu, J.-C.
- Venue
- Journal of Engineering Mechanics
- Published
- 2004-04
- Volume
- 130
- Issue
- 4
- Pages
- 437-446
- ISSN
- 0733-9399 (ISSN-L)
- 1943-7889
- DOI
- 10.1061/(asce)0733-9399(2004)130:4(437
- OpenAlex
- W2063980808
- Cited by
- 276
- References
- 14
- FWCI
- 66.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.