Structures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
This paper proposes application of single and multiple semiactive variable stiffness tuned mass dampers (STMD/SMTMD) for response control of multistory structures under several types of excitation. A new semiactive control algorithm is developed based on real-time frequency tracking of excitation signal by short time Fourier transform. A parametric study is performed in the frequency domain to investigate the dynamic characteristics and effectiveness of STMDs. Time history responses of single-degree-of-freedom and five-degree-of-freedom structures equipped with STMDs at the roof level, subjected to harmonic, stationary, and nonstationary excitations are presented. STMD/SMTMD are most effective when they have low damping ratios and the excitation frequency can be tracked. They are superior than their passive counterparts in reducing the response of the main structure both under force and base excitations. In case the fundamental frequency changes due to damage or deterioration of the main structure then the TMD will be off-tune; hence, it will lose its effectiveness significantly, whereas, the STMD is robust against such changes as it is always tuned to the excitation frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2009) · Encyclopedia of Neuroscience · doi:10.1007/978-3-540-29678-2_6014 · Cited by 2,850
(1996) · Adapted Wavelet Analysis · doi:10.1201/9781439863619-15 · Cited by 2,703
Mechanical Vibrations: Applications to Equipment
Mori, Y. (2017) · Wiley eBooks · doi:10.1002/9781119384502 · Cited by 882
Ramachandra Rao, A., Hamed, K. H., & Chen, H.-L. (2003) · Water Science and Technology Library · doi:10.1007/978-94-010-0117-5_5 · Cited by 437
Yamaguchi, H., & Harnpornchai, N. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290220105 · Cited by 341
Dynamic characterization of multiple tuned mass dampers and some design formulas
Abé, M., & Fujino, Y. (1994) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290230802 · Cited by 329 · cited 1×
“Abe and Fujino 1994 reported that a properly designed MTMD can be much more robust than a conventional TMD.”
BackgroundDynamic characteristics of multiple substructures with closely spaced frequencies
Xu, K., & Igusa, T. (1992) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290211203 · Cited by 326 · cited 1×
“Several researchers Xu and Igusa 1992; Igusa and Xu 1994; Yamaguchi and Harnpornchai 1993 studied the performance and optimum parameters of MTMD systems under harmonic and white noise excitations and showed that optimally designed MTMD system is more effective than the single TMD system.”
BackgroundPassive, Adaptive and Active Tuned Vibration Absorbers—A Survey
Sun, J. Q., Jolly, M. R., & Norris, M. A. (1995) · Journal of Mechanical Design · doi:10.1115/1.2836462 · Cited by 320
Tuned Mass Dampers for Buildings
McNamara, R. J. (1977) · Journal of the Structural Division · doi:10.1061/jsdeag.0004721 · Cited by 319
Seismic response controlled structure with Active Variable Stiffness system
Kobori, T., Takahashi, M., Nasu, T., Niwa, N., & Ogasawara, K. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290221102 · Cited by 311 · cited 1×
“Variable stiffness systems, with either on or off states, have been developed by Kobori and Takahashi 1993, Bobrow et al. 2000, and Yang et al. 2000.”
BackgroundPerformance of Multiple Mass Dampers under Random Loading
Kareem, A., & Kline, S. (1995) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1995)121:2(348) · Cited by 306 · cited 1×
“Kareem and Kline 1995 studied SDOF systems with MTMD under random loading.”
MethodVibration Control Using Multiple Tuned Mass Dampers
Igusa, T., & Xu, K. (1994) · Journal of Sound and Vibration · doi:10.1006/jsvi.1994.1341 · Cited by 295 · cited 1×
“Several researchers Xu and Igusa 1992; Igusa and Xu 1994; Yamaguchi and Harnpornchai 1993 studied the performance and optimum parameters of MTMD systems under harmonic and white noise excitations and showed that optimally designed MTMD system is more effective than the single TMD system.”
BackgroundSemi‐Active versus Passive or Active Tuned Mass Dampers for Structural Control
Hrovat, D., Barak, P., & Rabins, M. (1983) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1983)109:3(691 · Cited by 291 · cited 1×
“STMDs have been investigated by Hrovat et al. 1983, Abe 1996, and Abe and Igusa 1996.”
MethodNagarajaiah, S., & Varadarajan, N. (2005) · Engineering Structures · doi:10.1016/j.engstruct.2004.10.015 · Cited by 212 · cited 4×
“Recently, the STMD device has been studied by developing on-line tuning using empirical mode decomposition-Hilbert transform and shorttime Fourier transform STFT algorithms by Varadarajan and Nagarajaiah 2004 and Nagarajaiah and Varadarajan 2005, which tune the frequency of STMD and reduce the primary structural respo…”
BackgroundMethodInfluentialSelf-citationSeismic Effectiveness of Tuned Mass Dampers
Kaynia, A. M., Veneziano, D., & Biggs, J. M. (1981) · Journal of the Structural Division · doi:10.1061/jsdeag.0005760 · Cited by 198
Varadarajan, N., & Nagarajaiah, S. (2004) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(2004)130:4(451 · Cited by 172 · cited 2×
“Recently, the STMD device has been studied by developing on-line tuning using empirical mode decomposition-Hilbert transform and shorttime Fourier transform STFT algorithms by Varadarajan and Nagarajaiah 2004 and Nagarajaiah and Varadarajan 2005, which tune the frequency of STMD and reduce the primary structural respo…”
BackgroundMethodSelf-citationEffect of Tuned‐Mass Dampers on Seismic Response
Sladek, J. R., & Klingner, R. E. (1983) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1983)109:8(2004 · Cited by 156 · cited 1×
“Kaynia et al. 1981 and Sladek and Klingner 1983 reported that TMD is not effective in reducing response due to earthquake excitation.”
BackgroundOptimum absorber parameters for minimizing vibration response
Warburton, G. B. (1981) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290090306 · Cited by 142 · cited 1×
“Warburton 1981 studied the optimum parameters of a TMD system with a 2DOF main structure and reported that the parameters determined for 2DOF main structure are in close agreement with the ones for SDOF approximation of the same structure if the ratio of two natural frequencies of the main system is reasonably large.”
BackgroundResetting Semiactive Stiffness Damper for Seismic Response Control
Yang, J. N., Kim, J.-H., & Agrawal, A. K. (2000) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2000)126:12(1427 · Cited by 125 · cited 1×
“Variable stiffness systems, with either on or off states, have been developed by Kobori and Takahashi 1993, Bobrow et al. 2000, and Yang et al. 2000 .”
BackgroundPassive, Adaptive and Active Tuned Vibration Absorbers—A Survey
Sun, J., Jolly, M. R., & Norris, M. A. (1995) · Journal of vibration and acoustics · doi:10.1115/1.2838668 · Cited by 124
Tuned mass dampers for structures with closely spaced natural frequencies
Abé, M., & Igusa, T. (1995) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290240209 · Cited by 122 · cited 2×
“Abe and Igusa 1995 also reported that for structures with p closely spaced natural frequencies at least p TMDs are necessary to control the response and derived an analytical condition on the TMD placement that decouples the response of the system onto p SDOF structure/TMD systems.”
BackgroundSEMI-ACTIVE DYNAMIC VIBRATION ABSORBERS FOR CONTROLLING TRANSIENT RESPONSE
Abé, M., & Igusa, T. (1996) · Journal of Sound and Vibration · doi:10.1006/jsvi.1996.0588 · Cited by 94 · cited 1×
“STMDs have been investigated by Hrovat et al. 1983, Abe 1996, and Abe and Igusa 1996 .”
MethodSEMI-ACTIVE TUNED MASS DAMPERS FOR SEISMIC PROTECTION OF CIVIL STRUCTURES
ABÉ, M. (1996) · Earthquake Engineering & Structural Dynamics · doi:10.1002/(sici)1096-9845(199607)25:7<743::aid-eqe579>3.0.co;2-s · Cited by 78 · cited 1×
“STMDs have been investigated by Hrovat et al. 1983, Abe 1996, and Abe and Igusa 1996.”
MethodA New Approach to Shock Isolation and Vibration Suppression Using a Resetable Actuator1
Bobrow, J. E., Jabbari, F., & Thai, K. (1999) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.1286629 · Cited by 53 · cited 1×
“Variable stiffness systems, with either on or off states, have been developed by Kobori and Takahashi 1993, Bobrow et al. 2000, and Yang et al. 2000.”
BackgroundVARIABLE STIFFNESS AND INSTANTANEOUS FREQUENCY
Nagarajaiah, S., Nadathur, & Sahasrabudhe, S. (1999) · Cited by 9
Self-citationState of the Art of Structural Control
(2003) · doi:10.1061/(asce)0733-9445(2003)129:7(845 · cited 1×
“Several variable damping devices, such as magnetorheological, variable orifice, and electrorheological dampers have been developed Spencer and Nagarajaiah 2003 .”
Background
Cited by
Bi-directional vibration control of offshore wind turbines using a 3D pendulum tuned mass damper
Sun, C., & Jahangiri, V. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2017.12.011 · Cited by 262
Nagarajaiah, S. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.349 · Cited by 256
Self-citationDinh, V.-N., & Basu, B. (2015) · Structural Control and Health Monitoring · doi:10.1002/stc.1666 · Cited by 204
“The configurations and assumptions of MTMDs suggested by [18] are used in this paper.”
MethodNagarajaiah, S., & Basu, B. (2009) · Earthquake Engineering and Engineering Vibration · doi:10.1007/s11803-009-9120-6 · Cited by 201
“…a key role in the development of new time-frequency based controllers for semiactive, smart tuned mass dampers (Nagarajaiah et al., 1999; Nagarajaiah and Varadarajan, 2001, 2005; Nagarajaiah and Sonmez, 2007; Nagarajaiah, 2009; Narasimhan and Nagarajaiah, 2005; Varadarajan and Nagarajaiah, 2004).”
BackgroundSelf-citationSemi-active vibration absorber based on real-time controlled MR damper
Weber, F. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2014.01.017 · Cited by 180
Metadata
- Authors
- Nagarajaiah, S., & Sonmez, E.
- Venue
- Journal of Structural Engineering
- Published
- 2007-01
- Volume
- 133
- Issue
- 1
- Pages
- 67-77
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2007)133:1(67
- OpenAlex
- W1985675087
- Cited by
- 190
- References
- 26
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.