Human-Building Interaction Framework for Personalized Thermal Comfort-Driven Systems in Office Buildings
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Centrally controlled heating, ventilation, and air conditioning (HVAC) systems in commercial buildings are operated by building management systems (BMS) based on the predefined operational settings and a set of assumptions. Despite the high rate of energy consumption by HVAC systems in commercial buildings, observations showed that a significant portion of the occupants remain dissatisfied with thermal conditions. One of the main reasons is that HVAC systems do not take into account personalized comfort preferences in their operational rules. This study proposes a framework to integrate building occupants in the HVAC control loop, learn their comfort profiles, and control the HVAC system based on occupants’ personalized comfort profiles. The framework fuses occupants’ comfort perception indices (i.e., comfort votes provided by users and mapped to a numerical value), collected through participatory sensing, and ambient temperature data, collected through a sensor network, and computes occupants’ comfort profiles by using a fuzzy rule-based descriptive and predictive model. The performance of the comfort-profiling algorithm was assessed using human subject data and synthetically generated data. For actuation, a BMS controller was proposed and tested in two zones of an office building. The BMS controller uses a proportional controller algorithm that regulates room temperatures to be equidistant from preferred temperatures of all occupants in the same thermal zone. Validation of the framework components demonstrated that the nonlinear underlying pattern of the thermal comfort sensation scale could accurately be recognized. Results of the BMS controller experiments revealed that the proportional controller algorithm is capable of keeping the thermal zones’ temperatures in the ranges of preferred temperatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generating fuzzy rules by learning from examples
Wang, L.-X., & Mendel, J. (1991) · Proceedings of the 1991 IEEE International Symposium on Intelligent Control · doi:10.1109/isic.1991.187368 · Cited by 3,285
Dounis, A. I., & Caraiscos, C. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2008.09.015 · Cited by 851
Forty years of Fanger’s model of thermal comfort: comfort for all?
van Hoof, J. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2007.00516.x · Cited by 733
Coordinating occupant behavior for building energy and comfort management using multi-agent systems
Klein, L., Kwak, J.-Y., Kavulya, G., Jazizadeh, F., Becerik-Gerber, B., Varakantham, P., & Tambe, M. (2012) · Automation in Construction · doi:10.1016/j.autcon.2011.11.012 · Cited by 367
Self-citationCooling load prediction for buildings using general regression neural networks
Ben-Nakhi, A. E., & Mahmoud, M. A. E. (2003) · Energy Conversion and Management · doi:10.1016/j.enconman.2003.10.009 · Cited by 351
Wagner, A., Gossauer, E., Moosmann, C., Gropp, T., & Leonhart, R. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.02.013 · Cited by 343
Measuring and monitoring occupancy with an RFID based system for demand-driven HVAC operations
Li, N., Calis, G., & Becerik-Gerber, B. (2012) · Automation in Construction · doi:10.1016/j.autcon.2012.02.013 · Cited by 330
Self-citationThe WM method completed: a flexible fuzzy system approach to data mining
Wang, L.-X. (2003) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2003.819839 · Cited by 263
Corgnati, S. P., Filippi, M., & Viazzo, S. (2005) · Building and Environment · doi:10.1016/j.buildenv.2005.10.027 · Cited by 262
Intelligent light control using sensor networks
Singhvi, V., Krause, A., Guestrin, C., Garrett, J. H., & Matthews, H. S. (2005) · Proceedings of the 3rd international conference on Embedded networked sensor systems · doi:10.1145/1098918.1098942 · Cited by 246
Cited by
Kim, J., Schiavon, S., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.023 · Cited by 522
Kim, J., Zhou, Y., Schiavon, S., Raftery, P., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2017.12.011 · Cited by 478
Park, J. Y., & Nagy, Z. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.102 · Cited by 299
Personalized human comfort in indoor building environments under diverse conditioning modes
Li, D., Menassa, C. C., & Kamat, V. R. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.10.004 · Cited by 284
Jung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
Self-citationJazizadeh, F., Ghahramani, A., Becerik-Gerber, B., Kichkaylo, T., & Orosz, M. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2013.11.066 · Cited by 219
Self-citationOccupancy-based HVAC control systems in buildings: A state-of-the-art review
Esrafilian-Najafabadi, M., & Haghighat, F. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107810 · Cited by 218
Li, D., Menassa, C. C., & Kamat, V. R. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.07.025 · Cited by 209
Ghahramani, A., Tang, C., & Becerik-Gerber, B. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.04.017 · Cited by 188
Self-citationA systematic review of personal thermal comfort models
Arakawa Martins, L., Soebarto, V., & Williamson, T. (2022) · Building and Environment · doi:10.1016/j.buildenv.2021.108502 · Cited by 187
Digital building twins and blockchain for performance-based (smart) contracts
Hunhevicz, J. J., Motie, M., & Hall, D. M. (2022) · Automation in Construction · doi:10.1016/j.autcon.2021.103981 · Cited by 180
“For example, users might set up their own local heaters and coolers [87] or their work performance might decrease, leading to a rise in personnel costs [88].”
BackgroundSmart Textile‐Based Personal Thermal Comfort Systems: Current Status and Potential Solutions
Tabor, J., Chatterjee, K., & Ghosh, T. K. (2020) · Advanced Materials Technologies · doi:10.1002/admt.201901155 · Cited by 174
Aryal, A., & Becerik-Gerber, B. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106223 · Cited by 160
Self-citationHuman-in-the-Loop AI for HVAC Management Enhancing Comfort and Energy Efficiency
Liang, X., de Nijs, F., Say, B., & Wang, H. (2025) · Proceedings of the 16th ACM International Conference on Future and Sustainable Energy Systems · doi:10.1145/3679240.3734587 · Cited by 14
“These systems autonomously reduce heating or cooling during unoc-cupied periods and increase output as needed to maintain set-points [12, 17, 24, 27].”
Metadata
- Authors
- Jazizadeh, F., Ghahramani, A., Becerik-Gerber, B., Kichkaylo, T., & Orosz, M.
- Venue
- Journal of Computing in Civil Engineering
- Published
- 2014-01
- Volume
- 28
- Issue
- 1
- Pages
- 2-16
- ISSN
- 0887-3801 (ISSN-L)
- 1943-5487
- OpenAlex
- W2164213041
- Cited by
- 190
- References
- 29
- FWCI
- 15.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.