The DOI matches its Crossref record.
Performance of a 2-Story CLT House Subjected to Lateral Loads
Abstract
A 2-story full-scale model of a cross-laminated timber (CLT) house was tested under quasi-static monotonic and cyclic loading. The primary objectives were to investigate 3D system performance of a CLT structure subjected to lateral loads in terms of lateral strength and deformability capacity, global behavior of the structure, frequency response of the structure before and after each test, and performance of anchoring connectors (hold-downs, brackets) and connections between CLT panels. The house was 6.0×4.8 m in plan with a height of 4.8 m. A total of five (one push-over and four cyclic) quasi-static tests were performed, one direction at a time. Parameters, such as the direction of loading, number of hold-downs, and number of screws in perpendicular wall-to-wall connections, were varied in the tests. The CLT structure performed according to the design objectives, with the ultimate resistance being almost identical in both directions. Failure mechanisms, i.e., shear failure of nails in the brackets in the first story as a result of sliding and rocking of the CLT wall panels, were similar in all tests. Even after the maximum force was reached, no global instabilities of the house were detected. Torsion effects did not compromise the integrity, stability, or the lateral resistance of the building. The outcomes of the full-scale CLT house tests will be used for further analytical and numerical analyses to help the implementation of CLT as a structural system in the North American building codes and material standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cyclic Behavior of CLT Wall Systems: Experimental Tests and Analytical Prediction Models
Gavric, I., Fragiacomo, M., & Ceccotti, A. (2015) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001246 · Cited by 272
Self-citationExperimental Testing of Rocking Cross-Laminated Timber Walls with Resilient Slip Friction Joints
Hashemi, A., Zarnani, P., Masoudnia, R., & Quenneville, P. (2018) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001931 · Cited by 169
Lan, K., Kelley, S. S., Nepal, P., & Yao, Y. (2020) · Environmental Research Letters · doi:10.1088/1748-9326/abc5e6 · Cited by 95
Seismic Design of Cross-Laminated Timber Buildings
Tannert, T., Follesa, M., Fragiacomo, M., Gonzalez, P., Isoda, H., Moroder, D., Xiong, H., & van de Lindt, J. (2018) · Wood and Fiber Science · doi:10.22382/wfs-2018-037 · Cited by 77
Zhang, Z., & Lan, K. (2022) · Journal of Renewable Materials · doi:10.32604/jrm.2022.017506 · Cited by 12
Metadata
- Authors
- Popovski, M., & Gavric, I.
- Venue
- Journal of Structural Engineering
- Published
- 2016-04
- Volume
- 142
- Issue
- 4
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- OpenAlex
- W1500458166
- Cited by
- 211
- References
- 0
- FWCI
- 22.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of a 2-Story CLT House Subjected to Lateral Loads. https://app.cochat.ai/papers/10.1061/(asce)st.1943-541x.0001315
- The paper
- Popovski, M., & Gavric, I. (2016). Performance of a 2-Story CLT House Subjected to Lateral Loads. Journal of Structural Engineering. https://doi.org/10.1061/(asce)st.1943-541x.0001315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.