Abstract
The tuned viscous mass damper (TVMD) and tuned inerter damper (TID) are tuned inerter-based dampers (TIBDs) that can utilize amplified apparent mass and tuning effects. This study investigated the use of multiple TIBDs to mitigate the seismic responses of multi-degree-of-freedom (MDOF) structures. The locations and modes for tuning the TIBDs were analyzed by defining a placement index based on the H2 norm. The parameters of TVMDs and TIDs distributed throughout the structure and tuned to multiple modes were optimized by minimizing the H2 performance of the objective responses. The equivalent stiffness and damping of the TVMD and TID were considered to demonstrate TIBD control mechanisms, such as significant additional damping at the resonance frequency. As examples, 3-story and 10-story buildings were subjected to earthquakes with different spectra characteristics to validate the effectiveness of TIBD schemes. The results showed that distributed TIBDs tuned to properly selected modes significantly reduce the root-mean-square (RMS) responses of displacement and acceleration and perform superior than the viscous dampers and viscous mass dampers in reducing the peak displacement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis of mechanical networks: the inerter
Smith, M. C. (2002) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2002.803532 · Cited by 1,828
Using an inerter‐based device for structural vibration suppression
Lazar, I. F., Neild, S. A., & Wagg, D. J. (2014) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2390 · Cited by 799
Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper
Ikago, K., Saito, K., & Inoue, N. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1138 · Cited by 782
Cited by
Inerter-based structural vibration control: A state-of-the-art review
Ma, R., Bi, K., & Hao, H. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2021.112655 · Cited by 445
Xu, K., Bi, K., Han, Q., Li, X., & Du, X. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2018.12.067 · Cited by 211
De Domenico, D., Deastra, P., Ricciardi, G., Sims, N. D., & Wagg, D. J. (2019) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2018.11.012 · Cited by 203
Cao, L., & Li, C. (2019) · Structural Control and Health Monitoring · doi:10.1002/stc.2319 · Cited by 201
Shen, W., Niyitangamahoro, A., Feng, Z., & Zhu, H. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2019.109470 · Cited by 175
Metadata
- Authors
- Wen, Y., Chen, Z., & Hua, X.
- Venue
- Journal of Structural Engineering
- Published
- 2017-04
- Volume
- 143
- Issue
- 4
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- OpenAlex
- W2547988151
- Cited by
- 150
- References
- 3
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Evaluation of Tuned Inerter-Based Dampers for the Seismic Control of MDOF Structures. https://app.cochat.ai/papers/10.1061/(asce)st.1943-541x.0001680
- The paper
- Wen, Y., Chen, Z., & Hua, X. (2017). Design and Evaluation of Tuned Inerter-Based Dampers for the Seismic Control of MDOF Structures. Journal of Structural Engineering. https://doi.org/10.1061/(asce)st.1943-541x.0001680
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.