The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Simultaneous measurement of lateral and normal forces with an optical-beam-deflection atomic force microscope
Abstract
An atomic force microscope capable of measuring, simultaneously yet separately, lateral (‘‘frictional’’) and normal forces is described. A direction-dependent feature, absent in topological images, is found when scanning stepped surfaces of NaCl (001) in ultrahigh vacuum. A simple model is presented to account for this observation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Tip Surface Interactions in STM and AFM
Pethica, J. B., & Oliver, W. C. (1987) · Physica Scripta · doi:10.1088/0031-8949/1987/t19a/010 · Cited by 388
Structural and dynamical consequences of interactions in interfacial systems
Landman, U., Luedtke, W. D., & Ribarsky, M. W. (1989) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576154 · Cited by 162
Cited by
Nanotribology: friction, wear and lubrication at the atomic scale
Bhushan, B., Israelachvili, J. N., & Landman, U. (1995) · Nature · doi:10.1038/374607a0 · Cited by 1,601
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Calibration of frictional forces in atomic force microscopy
Ogletree, D. F., Carpick, R. W., & Salmeron, M. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147411 · Cited by 604
Friction measurements on phase-separated thin films with a modified atomic force microscope
Overney, R. M., Meyer, E., Frommer, J., Brodbeck, D., Lüthi, R., Howald, L., Giintherodt, H.-J., Fujihira, M., Takano, H., & Gotoh, Y. (1992) · Nature · doi:10.1038/359133a0 · Cited by 524
Noy, A., Vezenov, D. V., & Lieber, C. M. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.381 · Cited by 478
Biological applications of atomic force microscopy
Lal, R., & John, S. A. (1994) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1994.266.1.c1 · Cited by 402
The qPlus sensor, a powerful core for the atomic force microscope
Giessibl, F. J. (2019) · Review of Scientific Instruments · doi:10.1063/1.5052264 · Cited by 358
Schwarz, U. D., Zwörner, O., Köster, P., & Wiesendanger, R. (1997) · Physical Review B · doi:10.1103/physrevb.56.6987 · Cited by 290
Hard coatings with high temperature adaptive lubrication and contact thermal management: review
Voevodin, A. A., Muratore, C., & Aouadi, S. M. (2014) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2014.04.046 · Cited by 281
Chemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
Atomic-force-microscope study of contact area and friction onNbSe2
Lantz, M. A., O'Shea, S. J., Welland, M. E., & Johnson, K. L. (1997) · Physical Review B · doi:10.1103/physrevb.55.10776 · Cited by 253
J. Phys.: Condens. Matter, 13, 619
(2001) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/13/31/202 · Cited by 206
Microscale frictional response of bovine articular cartilage from atomic force microscopy
Park, S., Costa, K. D., & Ateshian, G. A. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.017 · Cited by 139
Bennewitz, R. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00845-x · Cited by 60
Metadata
- Authors
- Meyer, G., & Amer, N. M.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1990-11-12
- Volume
- 57
- Issue
- 20
- Pages
- 2089-2091
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1991169801
- Cited by
- 587
- References
- 3
- FWCI
- 6.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.