Wide-frequency specific heat spectrometer
Abstract
We have developed a technique to measure the frequency-dependent specific heat of a liquid over a frequency range exceeding five decades, 0.01–3000 Hz. The measurement is not performed adiabatically, but rather relies on heat diffusion from a thin, planar heater immersed in the liquid sample. The spectrometer has been used to study organic liquids near the glass transition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lower limit to the thermal conductivity of disordered crystals
Cahill, D. G., Watson, S. K., & Pohl, R. O. (1992) · Physical Review B · doi:10.1103/physrevb.46.6131 · Cited by 2,617
Thermal conductivity measurement from 30 to 750 K: the 3ω method
Cahill, D. G. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141498 · Cited by 1,928
Enthalpy relaxation and recovery in amorphous materials
Hodge, I. M. (1994) · Journal of Non-Crystalline Solids · doi:10.1016/0022-3093(94)90321-2 · Cited by 1,206
Scaling in the relaxation of supercooled liquids
Dixon, P. K., Wu, L., Nagel, S. R., Williams, B. D., & Carini, J. P. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.1108 · Cited by 592
Self-citationThermal conductivity of a -Si:H thin films
Cahill, D. G., Katiyar, M., & Abelson, J. R. (1994) · Physical Review B · doi:10.1103/physrevb.50.6077 · Cited by 523
Metadata
- Authors
- Birge, N. O., & Nagel, S. R.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1987-08-01
- Volume
- 58
- Issue
- 8
- Pages
- 1464-1470
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2084643515
- Cited by
- 175
- References
- 0
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wide-frequency specific heat spectrometer. https://app.cochat.ai/papers/10.1063/1.1139434
- The paper
- Birge, N. O., & Nagel, S. R. (1987). Wide-frequency specific heat spectrometer. Review of Scientific Instruments. https://doi.org/10.1063/1.1139434
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.