CoChat

Superconducting resonator and a cryogenic GaAs field-effect transistor amplifier as a single-ion detection system

Jefferts, S. R., Heavner, T., Hayes, P., Dunn, G. H. · 1993 · Review of Scientific Instruments

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

A current measuring system capable of detecting single ions is described. The detector operates at a frequency of nominally 900 kHz and utilizes a superconducting inductor with high Q(Q≊8500) and a cryogenic GaAs field-effect transistor (FET) amplifier with noise temperature less than 0.3 K. Noise measurements of the FET are presented along with details of the construction of the superconducting inductor.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.1144153

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Cited by

See all 25

Metadata

Authors
Jefferts, S. R., Heavner, T., Hayes, P., & Dunn, G. H.
Affiliations
National Institute of Standards and Technology (US)
Venue
Review of Scientific Instruments
Published
1993-03-01
Volume
64
Issue
3
Pages
737-740
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2054287873
Cited by
25
References
6
Citations by year
2025: 2 · 2024: 1 · 2022: 2 · 2017: 1 · 2016: 3 · 2014: 1 · 2013: 2 · 2012: 3
FWCI
0.88
Type
journal article
Language
en
Open access
closed
Locations
Review of Scientific Instruments (publishedVersion)
Topics
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle Detector Development and Performance
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting and THz Device Technology
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
Keywords
single ion detection, superconducting resonators, superconducting inductors, FET amplifier, current measurement, low noise amplifier, noise temperature, high-Q inductors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.