Superconducting resonator and a cryogenic GaAs field-effect transistor amplifier as a single-ion detection system
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A current measuring system capable of detecting single ions is described. The detector operates at a frequency of nominally 900 kHz and utilizes a superconducting inductor with high Q(Q≊8500) and a cryogenic GaAs field-effect transistor (FET) amplifier with noise temperature less than 0.3 K. Noise measurements of the FET are presented along with details of the construction of the superconducting inductor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Currents to Conductors Induced by a Moving Point Charge
Shockley, W. (1938) · Journal of Applied Physics · doi:10.1063/1.1710367 · Cited by 1,300
Motchenbacher, C. D., & Fitchen, F. C. (1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 208
Noise and fluctuations in electronic devices and circuits
Robinson, F. N. H. (1974) · CERN Document Server (European Organization for Nuclear Research) · Cited by 69
rf SQUID detector for single-ion trapping experiments
Weisskoff, R. M., Lafyatis, G. P., Boyce, K. R., Cornell, E. A., Flanagan, R. W., & Pritchard, D. E. (1988) · Journal of Applied Physics · doi:10.1063/1.340137 · Cited by 46
Moore, F. L., Brown, L. S., Farnham, D. L., Jeon, S., Schwinberg, P. B., & Dyck, R. S. V. (1992) · Physical Review A · doi:10.1103/physreva.46.2653 · Cited by 33
Cited by
Repp, J., Böhm, C., López-Urrutia, J. R. C., Dörr, A., Eliseev, S., George, S., Goncharov, M., Novikov, Y. N., Roux, C., Sturm, S., et al. (2012) · Applied Physics B · doi:10.1007/s00340-011-4823-6 · Cited by 90
Resolution of Single Spin Flips of a Single Proton
Mooser, A. H., Kracke, H., Blaum, K., Bräuninger, S. A., Franke, K., Leiteritz, C., Quint, W., Rodegheri, C. C., Ulmer, S., & Walz, J. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.140405 · Cited by 62
The quality factor of a superconducting rf resonator in a magnetic field
Ulmer, S., Kracke, H., Blaum, K., Kreim, S., Mooser, A., Quint, W., Rodegheri, C. C., & Walz, J. (2009) · Review of Scientific Instruments · doi:10.1063/1.3271537 · Cited by 56
Ulmer, S., Blaum, K., Kracke, H., Mooser, A., Quint, W., Rodegheri, C. C., & Walz, J. (2013) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2012.12.071 · Cited by 48
Electron g‐factor determinations in Penning traps
Sturm, S., Werth, G., & Blaum, K. (2013) · Annalen der Physik · doi:10.1002/andp.201300052 · Cited by 33
Image charge forces inside conducting boundaries
Tinkle, M. D., & Barlow, S. E. (2001) · Journal of Applied Physics · doi:10.1063/1.1383016 · Cited by 27
Single Microwave Photon Detection with a Trapped Electron
Cridland, A., Lacy, J., Pinder, J., & Verdú, J. (2016) · Photonics · doi:10.3390/photonics3040059 · Cited by 18
“The induced signal U is first amplified by a low-noise amplifier stage at 4 K [21,22].”
MethodAtomic mass of 6Li using a Penning-ion-trap mass spectrometer
Heavner, T. P., Jefferts, S. R., & Dunn, G. H. (2001) · Physical Review A · doi:10.1103/physreva.64.062504 · Cited by 17
Self-citationZou, S. F., & Konstantinov, D. (2022) · New Journal of Physics · doi:10.1088/1367-2630/ac9696 · Cited by 14
Electronic detection of a single particle in a coplanar-waveguide Penning trap
Al-Rjoub, A., & Verdú, J. (2012) · Applied Physics B · doi:10.1007/s00340-012-5069-7 · Cited by 6
Cryogenic Resonant Amplifier for Electron-on-Helium Image Charge Readout
Belyanchikov, M. A., Kraus, J. A., & Konstantinov, D. (2024) · Journal of Low Temperature Physics · doi:10.1007/s10909-023-03033-6 · Cited by 6
Reza, A., Banerjee, K., Das, P., Ray, K., Bandyopadhyay, S., & Dam, B. (2017) · Review of Scientific Instruments · doi:10.1063/1.4978799 · Cited by 6
The Magnetic Moments of the Proton and the Antiproton
Ulmer, S., & Smorra, C. (2014) · Springer tracts in modern physics · doi:10.1007/978-3-642-45201-7_5 · Cited by 7
The JILA Penning trap mass spectrometer
Heavner, T. P., Zuo, M., Hayes, P., et al. (1995) · Physica Scripta · doi:10.1088/0031-8949/1995/t59/058 · Cited by 5
Self-citationImproved comparison of bar P and P charge-to-mass ratios
Phillips, D. F., Quint, W., Gabrielse, G., Kalinowsky, H., Rouleau, G., & Jhe, W. (1995) · Physica Scripta · doi:10.1088/0031-8949/1995/t59/042 · Cited by 5
Image-charge detection of electrons on helium in an on-chip trapping device
Belianchikov, M., Morais, N., & Konstantinov, D. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.054026 · Cited by 5
Ultra-High-Resolution Mass Spectroscopy in Penning Traps
Dyck, R. S. V. (1995) · Methods of experimental physics · doi:10.1016/s0076-695x(08)60664-x · Cited by 5
Wang, J.-R., Wu, J.-F., Zhang, T.-H., Liu, J.-L., Peng, J.-T., Wang, J.-W., Shen, Y., Wei, B.-R., Zou, Y.-M., & Tu, B.-S. (2025) · Nuclear Science and Techniques · doi:10.1007/s41365-025-01797-y · Cited by 4
“In 1992, Jefferts et al. [37] described the development of a detection system consisting of a superconducting inductor and a GaAs field-effect transistor preamplifier for image current-signal readout.”
Mooser, A. H., Blaum, K., Kracke, H., Kreim, S., Quint, W., Rodegheri, C. C., Ulmer, S., & Walz, J. (2011) · Canadian Journal of Physics · doi:10.1139/p10-070 · Cited by 7
Development and characterization of a high frequency low noise amplifier
Reza, A., Misra, A., Chatterjee, I., et al. (2016) · National Conference on Communications · doi:10.1109/ncc.2016.7561113 · Cited by 2
Precision measurement of the atomic mass of /sup 6/Li using a Penning ion trap mass spectrometer
Heavner, T. P., Jefferts, S. R., & Dunn, G. H. (2002) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.1998.699804 · Cited by 1
Self-citationDevelopment of low noise amplifier and associated RF switching circuit for the penning ion trap
Reza, A., Sikdar, A. K., Das, P., Chatterjee, I., & Banerjee, K. (2016) · Indian Journal of Cryogenics · doi:10.5958/2349-2120.2016.00006.6 · Cited by 1
Precision measurement of the atomic mass of /sup 6/Li using a Penning ion trap mass spectrometer
Heavner, T. P., Jefferts, S. R., & Dunn, G. H. (1999) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.769560
Self-citationRiehle, F. (2003) · Wiley eBooks · doi:10.1002/3527605991.biblio
High frequency properties of a planar ion trap fabricated on a chip
Uribe, A., Mathad, A. C., Lacy, J. H., Pinder, J., Willetts, R., & Verdú, J. (2022) · Review of Scientific Instruments · doi:10.1063/5.0091745
Metadata
- Authors
- Jefferts, S. R., Heavner, T., Hayes, P., & Dunn, G. H.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1993-03-01
- Volume
- 64
- Issue
- 3
- Pages
- 737-740
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2054287873
- Cited by
- 25
- References
- 6
- Citations by year
- 2025: 2 · 2024: 1 · 2022: 2 · 2017: 1 · 2016: 3 · 2014: 1 · 2013: 2 · 2012: 3
- FWCI
- 0.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle Detector Development and Performance
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting and THz Device Technology
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Keywords
- single ion detection, superconducting resonators, superconducting inductors, FET amplifier, current measurement, low noise amplifier, noise temperature, high-Q inductors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.