The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Measurement of small forces using an optical trap
Abstract
A simple and sensitive method for detecting small forces applied to an optically trapped microsphere utilizes the transmitted beam of the trapping laser to monitor microsphere deflections within the potential well of the trap. The rms dynamic displacement detection sensitivity measured in the frequency range from 1 Hz to 10 kHz is ∼1 nm in the radial direction and ∼10 nm along the z (optic) axis. Radiation trapping force constants were calibrated against viscous drag on microspheres in the range between the Rayleigh (r<0.2λ) and Mie (r≫λ) size regimes. For a 1-μm-diam polystyrene sphere trapped with a 60 mW beam the rms spontaneous thermal motion limits the force sensitivity to better than 10−12 N and lateral spatial resolution to ∼10 nm in a frequency range from 1 Hz to the viscous rolloff frequency ∼1 kHz. The measured maximum trapping efficiencies are compared with the theoretical predictions of the ray-optics approximation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Bead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038
Cited by
Smith, S. B., Cui, Y., & Bustamante, C. (1996) · Science · doi:10.1126/science.271.5250.795 · Cited by 2,770
Interference model for back-focal-plane displacement detection in optical tweezers
Gittes, F., & Schmidt, C. F. (1998) · Optics Letters · doi:10.1364/ol.23.000007 · Cited by 623
Construction of multiple-beam optical traps with nanometer-resolution position sensing
Visscher, K., Gross, S. P., & Block, S. M. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577338 · Cited by 419
Raman Tweezers for Small Microplastics and Nanoplastics Identification in Seawater
Gillibert, R., Balakrishnan, G., Deshoules, Q., Tardivel, M., Magazzù, A., Donato, M. G., Maragò, O. M., Lamy de La Chapelle, M., Colas, F., Lagarde, F., et al. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b03105 · Cited by 348
[7] Optical-trap force transducer that operates by direct measurement of light momentum
Smith, S. B., Cui, Y., & Bustamante, C. (2003) · Methods in Enzymology · doi:10.1016/s0076-6879(03)61009-8 · Cited by 314
Metadata
- Authors
- Ghislain, L. P., Switz, N. A., & Webb, W. W.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1994-09-01
- Volume
- 65
- Issue
- 9
- Pages
- 2762-2768
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2024067117
- Cited by
- 213
- References
- 2
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of small forces using an optical trap. https://app.cochat.ai/papers/10.1063/1.1144613
- The paper
- Ghislain, L. P., Switz, N. A., & Webb, W. W. (1994). Measurement of small forces using an optical trap. Review of Scientific Instruments. https://doi.org/10.1063/1.1144613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.