The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
High-resolution ion mobility measurements
Abstract
Gas phase ion mobility measurements can resolve structural isomers for polyatomic ions and provide information about their geometries. A new experimental apparatus for performing high-resolution ion mobility measurements is described. The apparatus consists of a pulsed laser vaporization/desorption source coupled through an ion gate to a 63-cm-long drift tube. The ion gate is a critical component that prevents the diffusion of neutral species from the source into the drift tube. Ions travel along the drift tube under the influence of a uniform electric field. At the end of the drift tube some of the ions exit through a small aperture. They are focused into a quadrupole mass spectrometer, where they are mass analyzed, and then detected by an off-axis collision dynode and by dual microchannel plates. The apparatus is operated with a drift voltage of up to 14 000 V and a helium buffer gas pressure of around 500 Torr. The resolving power for ion mobility measurements is over an order of magnitude higher than has been achieved using conventional injected-ion drift tube techniques. Examples of the application of the new apparatus in resolving isomers of laser desorbed metallofullerenes, in studying silicon clusters generated by laser vaporization, and in following the isomerization of small nanocrystalline (NaCl)nCl− clusters as a function of temperature, are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Meek, J. M., & Craggs, J. D. (1953) · International Linear Collider · Cited by 1,525
Theory of plasma chromatography/gaseous electrophoresis. Review
Revercomb, H. E., & Mason, E. A. (1975) · Analytical Chemistry · doi:10.1021/ac60357a043 · Cited by 755
Hill, H. H., Siems, W. F., & St. Louis, R. H. (1990) · Analytical Chemistry · doi:10.1021/ac00222a001 · Cited by 737
Carbon cluster cations with up to 84 atoms: structures, formation mechanism, and reactivity
von Helden, G., Hsu, M. T., Gotts, N., & Bowers, M. T. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100133a011 · Cited by 593
Structures of carbon cluster ions from 3 to 60 atoms: Linears to rings to fullerenes
von Helden, G., Hsu, M.-T., Kemper, P. R., & Bowers, M. T. (1991) · The Journal of Chemical Physics · doi:10.1063/1.460783 · Cited by 503
Naked Protein Conformations: Cytochrome c in the Gas Phase
Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00145a037 · Cited by 491
Self-citationvon Helden, G., Gotts, N. G., & Bowers, M. T. (1993) · Nature · doi:10.1038/363060a0 · Cited by 423
Silicon cluster ions: Evidence for a structural transition
Jarrold, M. F., & Constant, V. A. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.2994 · Cited by 380
Self-citationvon Helden, G., Wyttenbach, T., & Bowers, M. T. (1995) · Science · doi:10.1126/science.267.5203.1483 · Cited by 363
Annealing C 60 + : Synthesis of Fullerenes and Large Carbon Rings
Hunter, J., Fye, J., & Jarrold, M. F. (1993) · Science · doi:10.1126/science.260.5109.784 · Cited by 220
Self-citationDrift Tube Studies of Atomic Clusters
Jarrold, M. F. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100001a004 · Cited by 208
Self-citationDissociation of large silicon clusters: the approach to bulk behavior
Jarrold, M. F., & Honea, E. C. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100176a028 · Cited by 194
Self-citationSmall carbon rings: dissociation, isomerization, and a simple model based on strain
Shelimov, K. B., Hunter, J. M., & Jarrold, M. F. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)80007-3 · Cited by 75
Self-citationThe structures of small iron-carbon cluster anions. Linear to planar to three-dimensional
von Helden, G., Gotts, N. G., Maître, P., & Bowers, M. T. (1994) · Chemical Physics Letters · doi:10.1016/0009-2614(94)00871-x · Cited by 67
Cited by
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
A Cyclic Ion Mobility-Mass Spectrometry System
Giles, K., Ujma, J., Wildgoose, J., Pringle, S., Richardson, K., Langridge, D., & Green, M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01838 · Cited by 510
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Biomolecule Analysis by Ion Mobility Spectrometry
Bohrer, B. C., Merenbloom, S. I., Koeniger, S. L., Hilderbrand, A. E., & Clemmer, D. E. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113001 · Cited by 492
Self-citation
Metadata
- Authors
- Dugourd, P., Hudgins, R. R., Clemmer, D. E., & Jarrold, M. F.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1997-02-01
- Volume
- 68
- Issue
- 2
- Pages
- 1122-1129
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1988008969
- Cited by
- 299
- References
- 15
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.