The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Conformation of Macromolecules in the Gas Phase: Use of Matrix-Assisted Laser Desorption Methods in Ion Chromatography
Abstract
Conformational data for macromolecules in the gas phase have been obtained by the coupling of a matrix-assisted laser desorption ion source to an ion chromatograph. A series of polyethylene glycol (PEG) polymers "cationized" (converted to a cation) by sodium ions (Na + PEG9 to Na + PEG19) and a protonated neurotransmitter protein, bradykinin, were studied. Mobilities of Na + PEG9 to Na + PEG19 are reported. Detailed modeling of Na + PEG9 with molecular mechanics methods indicates that the lowest energy structure has the Na + ion "solvated" by the polymer chain with seven oxygen atoms as nearest neighbors. The agreement between the model and experiment is within 1 percent for Na + PEG9, Na + PEG13, and Na + PEG17, giving strong support to both the method and the deduced structures. Similar agreement was obtained in initial studies that modeled experimental data for arginine-protonated bradykinin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
Gas-Phase Conformation of Biological Molecules: Bradykinin
Wyttenbach, T., von Helden, G., & Bowers, M. T. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9535928 · Cited by 384
Self-citationIon mobility–mass spectrometry: a new paradigm for proteomics
McLean, J. A., Ruotolo, B. T., Gillig, K. J., & Russell, D. H. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.10.003 · Cited by 309
Ion mobility in the pharmaceutical industry: an established biophysical technique or still niche?
Campuzano, I. D., & Lippens, J. L. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.11.008 · Cited by 42
Wang, X., Norgate, E., Dai, J., Benoit, F., Bristow, T., England, R. M., Kalapothakis, J. M. D., & Barran, P. E. (2025) · Nature Communications · doi:10.1038/s41467-025-59065-x · Cited by 7
Metadata
- Authors
- von Helden, G., Wyttenbach, T., & Bowers, M. T.
- Venue
- Science
- Published
- 1995-03-10
- Volume
- 267
- Issue
- 5203
- Pages
- 1483-1485
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2014140929
- Cited by
- 363
- References
- 1
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conformation of Macromolecules in the Gas Phase: Use of Matrix-Assisted Laser Desorption Methods in Ion Chromatography. https://app.cochat.ai/papers/10.1126/science.267.5203.1483
- The paper
- von Helden, G., Wyttenbach, T., & Bowers, M. T. (1995). Conformation of Macromolecules in the Gas Phase: Use of Matrix-Assisted Laser Desorption Methods in Ion Chromatography. Science. https://doi.org/10.1126/science.267.5203.1483
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.