The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
A variable-temperature scanning tunneling microscope capable of single-molecule vibrational spectroscopy
Abstract
The design and performance of a variable-temperature scanning tunneling microscope (STM) is presented. The microscope operates from 8 to 350 K in ultrahigh vacuum. The thermally compensated STM is suspended by springs from the cold tip of a continuous flow cryostat and is completely surrounded by two radiation shields. The design allows for in situ dosing and irradiation of the sample as well as for the exchange of samples and STM tips. With the STM feedback loop off, the drift of the tip–sample spacing is approximately 0.001 Å/min at 8 K. It is demonstrated that the STM is well-suited for the study of atomic-scale chemistry over a wide temperature range, for atomic-scale manipulation, and for single-molecule inelastic electron tunneling spectroscopy (IETS).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Studies by Scanning Tunneling Microscopy
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1982) · Physical Review Letters · doi:10.1103/physrevlett.49.57 · Cited by 4,777
Single-Molecule Vibrational Spectroscopy and Microscopy
Stipe, B. C., Rezaei, M. A., & Ho, W. (1998) · Science · doi:10.1126/science.280.5370.1732 · Cited by 1,384
Self-citationAn atomic switch realized with the scanning tunnelling microscope
Eigler, D. M., Lutz, C. P., & Rudge, W. E. (1991) · Nature · doi:10.1038/352600a0 · Cited by 785
Molecular Vibration Spectra by Electron Tunneling
Jaklevic, R. C., & Lambe, J. (1966) · Physical Review Letters · doi:10.1103/physrevlett.17.1139 · Cited by 655
Single-Molecule Dissociation by Tunneling Electrons
Stipe, B. C., Rezaei, M. A., Ho, W., Gao, S., Persson, M., & Lundqvist, B. I. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.4410 · Cited by 621
Self-citationInducing and Viewing the Rotational Motion of a Single Molecule
Stipe, B. C., Rezaei, M. A., & Ho, W. (1998) · Science · doi:10.1126/science.279.5358.1907 · Cited by 453
Self-citationMeyer, G. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147080 · Cited by 221
Site-Specific Displacement of Si Adatoms on Si(111)- (7×7)
Stipe, B. C., Rezaei, M. A., & Ho, W. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.4397 · Cited by 113
Self-citationLow-temperature ultra-high-vacuum scanning tunneling microscope
Gaisch, R., Gimzewski, J. K., Reihl, B., Schlittler, R. R., Tschudy, M., & Schneider, W. (1992) · Ultramicroscopy · doi:10.1016/0304-3991(92)90495-6 · Cited by 102
Ferris, J. H., Kushmerick, J. G., Johnson, J. A., Youngquist, M. G., Kessinger, R. B., Kingsbury, H. F., & Weiss, P. S. (1998) · Review of Scientific Instruments · doi:10.1063/1.1149000 · Cited by 50
Cited by
Towards quantum superpositions of a mirror
Marshall, W., Simon, C., Penrose, R., & Bouwmeester, D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.130401 · Cited by 960
Metzger, R. M. (2015) · Chemical Reviews · doi:10.1021/cr500459d · Cited by 380
Metadata
- Authors
- Stipe, B. C., Rezaei, M. A., & Ho, W.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1999-01-01
- Volume
- 70
- Issue
- 1
- Pages
- 137-143
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2063203432
- Cited by
- 287
- References
- 10
- FWCI
- 17.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A variable-temperature scanning tunneling microscope capable of single-molecule vibrational spectroscopy. https://app.cochat.ai/papers/10.1063/1.1149555
- The paper
- Stipe, B. C., Rezaei, M. A., & Ho, W. (1999). A variable-temperature scanning tunneling microscope capable of single-molecule vibrational spectroscopy. Review of Scientific Instruments. https://doi.org/10.1063/1.1149555
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.