Ultrastable superconducting magnet system for a penning trap mass spectrometer
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
A custom-designed magnet/cryostat system is described which has demonstrated remarkably improved field stability over previous designs. To shield from external magnetic noise, a custom-fabricated flux-gate device remotely senses the changes in magnetic field and cancels them out at the site of the magnet/cryostat via a 1.7-m-diam Helmholtz coil. To provide further shielding, the basic superconducting solenoid includes a passive flux-stabilizing coil. To stabilize internal field shifts, the temperature of the materials in the immediate vicinity of the solenoid (which have a temperature-dependent susceptibility) is stabilized via the new cryostat geometry and by controlling the pressure of the evaporating liquid helium to a few parts per million. As a result, the total system now has a composite shielding factor of approximately 104 and an overall temporal stability on the order of 17(2) parts in 1012 per hour. This instrument, the heart of our new Penning trap mass spectrometer, has recently been used to determine a preliminary value of the proton’s atomic mass to an accuracy of 1.4 parts in 1010. With the new magnet/cryostat system, this spectrometer now has a potential resolution which exceeds 2 parts in 1011 with 100 hours of data using a single carbon 4+ ion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
New high-precision comparison of electron and positron g factors
Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.26 · Cited by 659
Self-citationAbstracts of Contributed Papers
Henry, R. C., Hesser, J. E., McClintock, W., Audouze, J., Schramm, D. N., Kohman, T. P., Huey, J. M., Cowan, G. A., Donn, B. D., Chappelle, E. W., et al. (1973) · Astrophysics and Space Science Library · doi:10.1007/978-94-010-2658-1_10 · Cited by 171
Coaxial Resonators with Helical Inner Conductor
Macalpine, W., & Schildknecht, R. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287128 · Cited by 159
Self-shielding superconducting solenoid systems
Gabrielse, G., & Tan, J. (1988) · Journal of Applied Physics · doi:10.1063/1.340416 · Cited by 95
Number dependency in the compensated Penning trap
Van Dyck, R. S., Moore, F. L., Farnham, D. L., & Schwinberg, P. B. (1989) · Physical Review A · doi:10.1103/physreva.40.6308 · Cited by 94
Self-citationGabrielse, G., Phillips, D., Quint, W., Kalinowsky, H., Rouleau, G., & Jhe, W. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.3544 · Cited by 91
High mass resolution with a new variable anharmonicity Penning trap
Van Dyck, R. S., Wineland, D. J., Ekstrom, P. A., & Dehmelt, H. G. (1976) · Applied Physics Letters · doi:10.1063/1.88793 · Cited by 87
Accurate atomic mass measurements from Penning trap mass comparisons of individual ions
Difilippo, F., Vasant Natarajan, A., Bradley, M. P., Palmer, F., & Pritchard, D. E. (1995) · Physica Scripta · doi:10.1088/0031-8949/1995/t59/018 · Cited by 64
Magnetic Susceptibility of Materials Commonly Used in the Construction of Cryogenic Apparatus
Salinger, G. L., & Wheatley, J. C. (1961) · Review of Scientific Instruments · doi:10.1063/1.1717549 · Cited by 63
Precision mass measurements in the UW-PTMS and the electron's "atomic mass"
Dyck, R. S. V., Farnham, D. L., & Schwinberg, P. B. (1995) · Physica Scripta · doi:10.1088/0031-8949/1995/t59/017 · Cited by 43
Self-citationA Compensated Penning Trap Mass Spectrometer and the3
Dyck, R. S. V., Farnham, D. L., & Schwinberg, P. B. (1992) · Journal of Modern Optics · doi:10.1080/09500349214550251 · Cited by 40
Self-citationHigh precision Penning trap mass spectroscopy and a new measurement of the proton’s “atomic mass”
Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B. (1999) · AIP Conference Proceedings · doi:10.1063/1.57450 · Cited by 38
Self-citationMoore, F. L., Brown, L. S., Farnham, D. L., Jeon, S., Schwinberg, P. B., & Dyck, R. S. V. (1992) · Physical Review A · doi:10.1103/physreva.46.2653 · Cited by 33
Self-citationAtomic, Molecular, and Optical Physics: Charged Particles
(1995) · Methods of experimental physics · doi:10.1016/s0076-695x(08)x6039-9 · Cited by 30
Research works printed but not linked: 1
- 1990, Physica B, 165&166, 147
Cited by
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Quantum computing with trapped ions
HAFFNER, H., ROOS, C., & BLATT, R. (2008) · Physics Reports · doi:10.1016/j.physrep.2008.09.003 · Cited by 1,154
“These experiments were made possible by choosing a particular geometry of the superconducting coils to shield the external magnetic fields (Dyck et al., 1999), especially of high importance for small fields.”
MethodCODATA recommended values of the fundamental physical constants: 1998
Mohr, P. J., & Taylor, B. N. (2000) · Reviews of Modern Physics · doi:10.1103/revmodphys.72.351 · Cited by 768
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 685
Cavity control of a single-electron quantum cyclotron: Measuring the electron magnetic moment
Hanneke, D., Fogwell Hoogerheide, S., & Gabrielse, G. (2011) · Physical Review A · doi:10.1103/physreva.83.052122 · Cited by 356
Metadata
- Authors
- Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B.
- Affiliations
- Department of Physics, Box 351560, University of Washington, Seattle, Washington 98195-1560
- University of Washington (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1999-03-01
- Volume
- 70
- Issue
- 3
- Pages
- 1665-1671
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2056891542
- Cited by
- 63
- References
- 14
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 2 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 3 · 2014: 1 · 2013: 4 · 2012: 2
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- superconducting magnets, Penning trap mass spectrometer, magnetic field stability, cryostat design, Helmholtz coil, temperature stabilization, high-resolution mass spectrometry, carbon ions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.