CoChat

High precision Penning trap mass spectroscopy and a new measurement of the proton’s “atomic mass”

Van Dyck, Robert S., Farnham, Dean L., Zafonte, Steven L., Schwinberg, Paul B. · 1999 · AIP Conference Proceedings
Cited by 38

The DOI matches its Crossref record.

Abstract

The Penning trap mass spectrometer (PTMS) at the University of Washington has been rebuilt into a new state-of-the-art magnet/cryostat system with external Helmholtz compensation coils (controlled by a nearby flux-gate sensor). This system gives a total magnetic shielding factor of ∼104 (which includes the effects of a passive internal flux-stabilizing coil supplied by the manufacturer). When the new magnet/cryostat is fitted with a system to control its boil-off pressure, the typical temporal field stability is ∼−0.017(2) ppb/h. The ultimate resolution of this improved spectrometer is expected to exceed 0.020 ppb with 100 hours of data using a single C4+ ion. The comparison of a C4+ ion with a C5+ ion suggests that the spectrometer’s accuracy may indeed match its resolution. To demonstrate the spectrometer’s improved performance over its previous version, the cyclotron frequency of a single proton is compared to the corresponding frequency of a single C4+ ion, yielding a determination of the proton’s atomic mass given by MP=1,007,276,466.89(14) nu. The primary systematic error (overcome in this case) is due to a position sensitivity within the non-uniform magnetic field, enhanced by the electrostatic trapping potentials of these ions which differ by a factor of three. A residual limitation to the overall field stability appears to be due to a long-term temperature-dependent temporal wander in the magnetic field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.57450

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 38

Metadata

Authors
Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B.
Venue
AIP Conference Proceedings
Publisher
AIP
Published
1999
Pages
101-110
ISSN
0094-243X (ISSN-L)
OpenAlex
W2014588320
Cited by
38
References
0
FWCI
10.66
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High precision Penning trap mass spectroscopy and a new measurement of the proton’s “atomic mass”. https://app.cochat.ai/papers/10.1063/1.57450
The paper
Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B. (1999). High precision Penning trap mass spectroscopy and a new measurement of the proton’s “atomic mass”. AIP Conference Proceedings. https://doi.org/10.1063/1.57450

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.