Ultrastable superconducting magnet system for a penning trap mass spectrometer
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
A custom-designed magnet/cryostat system is described which has demonstrated remarkably improved field stability over previous designs. To shield from external magnetic noise, a custom-fabricated flux-gate device remotely senses the changes in magnetic field and cancels them out at the site of the magnet/cryostat via a 1.7-m-diam Helmholtz coil. To provide further shielding, the basic superconducting solenoid includes a passive flux-stabilizing coil. To stabilize internal field shifts, the temperature of the materials in the immediate vicinity of the solenoid (which have a temperature-dependent susceptibility) is stabilized via the new cryostat geometry and by controlling the pressure of the evaporating liquid helium to a few parts per million. As a result, the total system now has a composite shielding factor of approximately 104 and an overall temporal stability on the order of 17(2) parts in 1012 per hour. This instrument, the heart of our new Penning trap mass spectrometer, has recently been used to determine a preliminary value of the proton’s atomic mass to an accuracy of 1.4 parts in 1010. With the new magnet/cryostat system, this spectrometer now has a potential resolution which exceeds 2 parts in 1011 with 100 hours of data using a single carbon 4+ ion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
New high-precision comparison of electron and positron g factors
Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.26 · Cited by 659
Self-citationAbstracts of Contributed Papers
Henry, R. C., Hesser, J. E., McClintock, W., Audouze, J., Schramm, D. N., Kohman, T. P., Huey, J. M., Cowan, G. A., Donn, B. D., Chappelle, E. W., et al. (1973) · Astrophysics and Space Science Library · doi:10.1007/978-94-010-2658-1_10 · Cited by 171
Coaxial Resonators with Helical Inner Conductor
Macalpine, W., & Schildknecht, R. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287128 · Cited by 159
Self-shielding superconducting solenoid systems
Gabrielse, G., & Tan, J. (1988) · Journal of Applied Physics · doi:10.1063/1.340416 · Cited by 95
Number dependency in the compensated Penning trap
Van Dyck, R. S., Moore, F. L., Farnham, D. L., & Schwinberg, P. B. (1989) · Physical Review A · doi:10.1103/physreva.40.6308 · Cited by 94
Self-citationGabrielse, G., Phillips, D., Quint, W., Kalinowsky, H., Rouleau, G., & Jhe, W. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.3544 · Cited by 91
High mass resolution with a new variable anharmonicity Penning trap
Van Dyck, R. S., Wineland, D. J., Ekstrom, P. A., & Dehmelt, H. G. (1976) · Applied Physics Letters · doi:10.1063/1.88793 · Cited by 87
Accurate atomic mass measurements from Penning trap mass comparisons of individual ions
Difilippo, F., Vasant Natarajan, A., Bradley, M. P., Palmer, F., & Pritchard, D. E. (1995) · Physica Scripta · doi:10.1088/0031-8949/1995/t59/018 · Cited by 64
Magnetic Susceptibility of Materials Commonly Used in the Construction of Cryogenic Apparatus
Salinger, G. L., & Wheatley, J. C. (1961) · Review of Scientific Instruments · doi:10.1063/1.1717549 · Cited by 63
Precision mass measurements in the UW-PTMS and the electron's "atomic mass"
Dyck, R. S. V., Farnham, D. L., & Schwinberg, P. B. (1995) · Physica Scripta · doi:10.1088/0031-8949/1995/t59/017 · Cited by 43
Self-citation
Research works printed but not linked: 1
- 1990, Physica B, 165&166, 147
Cited by
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Quantum computing with trapped ions
HAFFNER, H., ROOS, C., & BLATT, R. (2008) · Physics Reports · doi:10.1016/j.physrep.2008.09.003 · Cited by 1,154
“These experiments were made possible by choosing a particular geometry of the superconducting coils to shield the external magnetic fields (Dyck et al., 1999), especially of high importance for small fields.”
MethodCODATA recommended values of the fundamental physical constants: 1998
Mohr, P. J., & Taylor, B. N. (2000) · Reviews of Modern Physics · doi:10.1103/revmodphys.72.351 · Cited by 768
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 685
Cavity control of a single-electron quantum cyclotron: Measuring the electron magnetic moment
Hanneke, D., Fogwell Hoogerheide, S., & Gabrielse, G. (2011) · Physical Review A · doi:10.1103/physreva.83.052122 · Cited by 356
Fakultät für Physik und Astronomie
Physik, Schultz-Coulon, H.-C., Herrmann, N., Levin, I., & Ostrowski, A. (2007) · Cited by 288
An Ion Balance for Ultra-High-Precision Atomic Mass Measurements
Rainville, S., Thompson, J. K., & Pritchard, D. E. (2004) · Science · doi:10.1126/science.1092320 · Cited by 133
Repp, J., Böhm, C., López-Urrutia, J. R. C., Dörr, A., Eliseev, S., George, S., Goncharov, M., Novikov, Y. N., Roux, C., Sturm, S., et al. (2012) · Applied Physics B · doi:10.1007/s00340-011-4823-6 · Cited by 90
BASE – The Baryon Antibaryon Symmetry Experiment
Smorra, C., Blaum, K., Bojtar, L., Borchert, M., Franke, K. A., Higuchi, T., Leefer, N., Nagahama, H., Matsuda, Y., Mooser, A., et al. (2015) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2015-02607-4 · Cited by 82
The UW-PTMS: Systematic studies, measurement progress, and future improvements
Dyck, R. S. V., Pinegar, D. B., van Liew, S., & Zafonte, S. L. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.01.038 · Cited by 93
Self-citationThe LEBIT 9.4 T Penning trap mass spectrometer
Ringle, R., Bollen, G., Prinke, A. M., Savory, J., Schury, P., Schwarz, S., & Sun, T. (2009) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2009.03.207 · Cited by 78
Phase-Sensitive Cyclotron Frequency Measurements at Ultralow Energies
Sturm, S., Wagner, A., Schabinger, B., & Blaum, K. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.143003 · Cited by 76
Wang, T., Kimball, D. F. J., Sushkov, A. O., Aybas, D., Blanchard, J. W., Centers, G., O’Kelley, S. R., Wickenbrock, A., Fang, J., & Budker, D. (2017) · Physics of the Dark Universe · doi:10.1016/j.dark.2017.11.003 · Cited by 79
High- Q Magnetic Levitation and Control of Superconducting Microspheres at Millikelvin Temperatures
Hofer, J., Gross, R., Higgins, G. T., Huebl, H., Kieler, O., Kleiner, R., Koelle, D., Schmidt, P., Slater, J. A., Trupke, M., et al. (2023) · Physical Review Letters · doi:10.1103/physrevlett.131.043603 · Cited by 72
Redshaw, M., McDaniel, J., & Myers, E. G. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.093002 · Cited by 71
Ultraprecise Atomic Mass Measurement of the α Particle and He4
Dyck, R. S. V., Zafonte, S. L., van Liew, S., Pinegar, D. B., & Schwinberg, P. B. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.220802 · Cited by 78
Self-citationKetter, J., Eronen, T., Höcker, M., Streubel, S., & Blaum, K. (2013) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2013.10.005 · Cited by 78
“y important, not only because they relate the eigenfrequencies in the Penning trap to the free-space cyclotron-frequency ! c. Given the extraordinary stability achievable with superconducting magnets [29, 30], the magnetic field is the gold standard for connecting the eigenfrequencies of a particle to its mass. Note th…”
BackgroundThe most precise atomic mass measurements in Penning traps
Myers, E. G. (2013) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2013.03.018 · Cited by 71
Fadeev, P., Wang, T., Band, Y. B., Budker, D., Graham, P. W., Sushkov, A. O., & Kimball, D. F. J. (2021) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.103.044056 · Cited by 53
Redshaw, M., McDaniel, J., Shi, W., & Myers, E. G. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.01.015 · Cited by 42
Ultra-Precise Mass Measurements Using the UW-PTMS
Dyck, R. S. V., Zafonte, S. L., & Schwinberg, P. B. (2001) · Hyperfine Interactions · doi:10.1023/a:1011914310458 · Cited by 45
Self-citationElectron g‐factor determinations in Penning traps
Sturm, S., Werth, G., & Blaum, K. (2013) · Annalen der Physik · doi:10.1002/andp.201300052 · Cited by 33
Ultra-precise single-ion atomic mass measurements on deuterium and helium-3
Zafonte, S. L., & Dyck, R. S. V. (2015) · Metrologia · doi:10.1088/0026-1394/52/2/280 · Cited by 31
Self-citationDiamagnetic correction to the9Be+ground-state hyperfine constant
Shiga, N., Itano, W. M., & Bollinger, J. J. (2011) · Physical Review A · doi:10.1103/physreva.84.012510 · Cited by 30
Toward a more accurate Q value measurement of tritium: status of THe-Trap
Streubel, S., Eronen, T., Höcker, M., Ketter, J., Schuh, M., Dyck, R. S. V., & Blaum, K. (2013) · Applied Physics B · doi:10.1007/s00340-013-5669-x · Cited by 27
Marie-Jeanne, M., Alonso, J., Blaum, K., Djekić, S., Dworschak, M., Hager, U., Herlert, A., Nagy, S., Savreux, R., Schweikhard, L., et al. (2008) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2008.01.061 · Cited by 25
Progress with the MPIK/UW-PTMS in Heidelberg
Diehl, C., Blaum, K., Höcker, M., Ketter, J., Pinegar, D. B., Streubel, S., & Dyck, R. S. V. (2011) · Hyperfine Interactions · doi:10.1007/s10751-011-0324-6 · Cited by 24
“In order to stabilize the magnetic field around the Penning traps, several systems already in use with the older UW-PTMS [13] have been installed and improved.”
MethodInfluentialSuperconducting Levitated Detector of Gravitational Waves
Carney, D., Higgins, G. T., Marocco, G., & Wentzel, M. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.181402 · Cited by 23
Ultra-Precise Mass Measurements Using the UW-PTMS
Dyck, R. S. V., Zafonte, S. L., & Schwinberg, P. B. (2001) · Springer eBooks · doi:10.1007/978-94-015-1270-1_12 · Cited by 22
Self-citationVibration-induced field fluctuations in a superconducting magnet
Britton, J. W., Bohnet, J. G., Sawyer, B. C., Uys, H., Biercuk, M. J., & Bollinger, J. J. (2016) · Physical Review A · doi:10.1103/physreva.93.062511 · Cited by 20
Precision Nuclear Measurements with Ion Traps
Savard, G., & Werth, G. (2000) · Annual Review of Nuclear and Particle Science · doi:10.1146/annurev.nucl.50.1.119 · Cited by 21
High-accuracy Penning trap mass measurements with stored and cooled exotic ions
Blaum, K., Nagy, S., & Werth, G. (2009) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/42/15/154015 · Cited by 21
Devlin, J. A., Wursten, E., Harrington, J. A., Higuchi, T., Blessing, P. E., Borchert, M. J., Erlewein, S., Hansen, J. J., Morgner, J., Bohman, M., et al. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.044012 · Cited by 17
BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Smorra, C., Abbass, F., Schweitzer, D., Bohman, M., Devine, J., Dutheil, Y., Hobl, A., Arndt, B. P., Bauer, B. B., Devlin, J. A., et al. (2023) · Review of Scientific Instruments · doi:10.1063/5.0155492 · Cited by 15
High-accuracy Penning trap mass measurements with stored and cooled exotic ions
Blaum, K., Nagy, S., & Werth, G. (2009) · Max Planck Digital Library · Cited by 12
Precision measurements with non-laser-cooled trapped ions
Karr, J. (2009) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/42/15/154018 · Cited by 8
Stabilization and control of persistent current magnets using variable inductance
Brouwer, L., Shen, T., Norris, R., Hafalia, A. R., Schlueter, R., Wang, L., Ciston, J., Ercius, P. A., Ji, Q., Maňkoš, M., et al. (2022) · Superconductor Science and Technology · doi:10.1088/1361-6668/ac549b · Cited by 8
Hanneke, D. (2008) · PhDT · Cited by 6
Ketter, J. (2015) · heiDOK (Heidelberg University) · doi:10.17617/2.2148850 · Cited by 17
“Since carefully-designed superconducting magnets [163] with additional stabilization systems produce magnetic fields of extraordinary intrinsic temporal stability on the order of a few parts in 1012 per hour, they are the gold standard for relating a motional frequency of a particle to its charge and mass via Equation…”
BackgroundKaiser, A., Dickopf, S., Door, M., Behr, R., Beutel, U., Eliseev, S., Kaushik, A., Kromer, K., Müller, M., Palafox, L., et al. (2024) · Applied Physics Letters · doi:10.1063/5.0206779 · Cited by 5
Quantum computing with trapped ions
Häffner, H., Roos, C. F., Becher, C., Hänsel, W., Körber, T., Schmidt‐Kaler, F., Riebe, M., Benhelm, J., Lancaster, G. P. T., Chek-al-kar, D., et al. (2006) · European Quantum Electronics Conference (EQEC) · doi:10.1109/eqec.2005.1567473 · Cited by 5
Highly-charged ions and high-resolution mass spectrometry in a Penning trap
Nagy, S., Blaum, K., & Schuch, R. H. (2008) · Lecture notes in physics · doi:10.1007/978-3-540-77817-2_5 · Cited by 6
Two-ion control and polarization forces for precise mass comparisons
Thompson, J. K. (2003) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 5
Precision Mass Measurements at THe-Trap and the FSU trap
Höcker, M. (2016) · heiDOK (Heidelberg University) · doi:10.11588/heidok.00021680 · Cited by 10
Quantum-logic spectroscopy of an electron or positron for precise tests of the standard model
Fan, X., Noguchi, A., & Taniguchi, K. (2025) · Physical Review A · doi:10.1103/physreva.111.042806 · Cited by 5
A two-ion balance for high precision mass spectrometry
Rainville, S. (2003) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 10
Redshaw, M., Barquest, B. R., Bollen, G., Bustabad, S. E., Campbell, C. M., Ferrer, R., Gehring, A. E., Kwiatkowski, A. A., Lincoln, D. L., Morrissey, D. J., et al. (2011) · Hyperfine Interactions · doi:10.1007/s10751-011-0319-3 · Cited by 3
Planar, strong magnetic field source for a chip ion trap
Pinder, J., Lacy, J. H., Willetts, R., Cridland Mathad, A., Uribe, A., & Verdú, J. (2020) · Review of Scientific Instruments · doi:10.1063/5.0024735 · Cited by 2
Gabrielse, G., Hoogerheide, S. F., Dorr, J. C., & Novitski, E. (2014) · Springer tracts in modern physics · doi:10.1007/978-3-642-45201-7_1 · Cited by 10
Fritioff, T. (2002) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 2
Demonstration of a spherical Penning trap for single electrons
Fang, Z., & Fan, X. (2026) · Physical Review A · doi:10.1103/n3xf-344l · Cited by 1
“The cyclotron motion of a centered electron therefore couples, to leading order, only to TM m = ± 1 n =1 p , and in the typically experimentally accessible window, 0 ω c / (2 π ) 168 GHz (0 T B 6 T)[34–36], only three such modes exist: TM ± 111 , TM ± 112 , and TM ± 113 .”
Single electrons in a dual-plane printed-circuit-board Penning trap
Anonymous, Sukra, B., & Fan, X. (2026) · Physical Review Applied · doi:10.1103/k25f-9spd · Cited by 1
Motion of a Single Particle in a Real Penning Trap
Vogel, M. (2024) · Springer series on atomic, optical, and plasma physics · doi:10.1007/978-3-031-55420-9_7 · Cited by 1
Streubel, S. (2014) · heiDOK (Heidelberg University) · doi:10.11588/heidok.00016870 · Cited by 9
Verbesserungen der Ionennachweissysteme des Präzisions-Penningfallen-Massenspektrometers TRIGA-TRAP
Ketter, J. (2009) · Max Planck Digital Library · Cited by 7
Neidherr, D. (2010) · Gutenberg Open Science · doi:10.25358/openscience-2268 · Cited by 1
der Doktorw, E. (2005)
Precision mass measurements for studies of nucleosynthesis via the rapid neutron-capture process
Atanasov, D. (2016) · heiDOK (Heidelberg University) · doi:10.11588/heidok.00021444 · Cited by 2
Motion of a Single Particle in a Real Penning Trap
Vogel, M. (2018) · Springer series on atomic, optical, and plasma physics · doi:10.1007/978-3-319-76264-7_6
Mass Measurements of Neon Isotopes at THe-Trap
Segal, T. (2019) · heiDOK (Heidelberg University) · doi:10.11588/heidok.00027321
Technical Design Report of BASE-STEP
Smorra, C., Ulmer, S., Walz, J., Latacz, B. M., Popper, D., Wiesinger, M., Mooser, A. H., Borchert, M. J., Dutheil, Y., Matsuda, Y., et al. (2021) · CERN Document Server (European Organization for Nuclear Research) · Cited by 5
Sukhoruchkin, S. I., & Soroko, Z. N. (2009) · Numerical data and functional relationships in science and technology. Group I, Elementary particles, nuclei and atoms · doi:10.1007/978-3-540-69945-3_1
Redshaw, M., Barquest, B. R., Bollen, G., Bustabad, S. E., Campbell, C. M., Ferrer, R., Gehring, A. E., Kwiatkowski, A. A., Lincoln, D. L., Morrissey, D. J., et al. (2011) · Springer eBooks · doi:10.1007/978-94-007-2588-1_25
Progress with the MPIK/UW-PTMS in Heidelberg
Diehl, C., Blaum, K., Höcker, M., Ketter, J., Pinegar, D. B., Streubel, S., & Dyck, R. S. V. (2011) · Springer eBooks · doi:10.1007/978-94-007-2588-1_30
Fourier transform mass analyzers
Игоревич, Я. М. (2025) · Advances in imaging and electron physics · doi:10.1016/b978-0-443-31720-0.00004-8
(2025) · Advances in imaging and electron physics · doi:10.1016/b978-0-443-31720-0.09998-8
Kryukov, E., Karabanov, A. A., Langlais, D. B., Iuga, D., Moitra, S., & Good, J. A. (2025) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2025.107985
Berechnungen zu den Magnetfeldkorrekturspulen am THe-Trap-Experiment
Dickopf, S. (2017) · MPG.PuRe (Max Planck Society)
Design and implementation of a non-destructive ion detection system for the 3He g-factor experiment
Müller, M. (2020) · MPG.PuRe (Max Planck Society)
Metadata
- Authors
- Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B.
- Affiliations
- Department of Physics, Box 351560, University of Washington, Seattle, Washington 98195-1560
- University of Washington (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1999-03-01
- Volume
- 70
- Issue
- 3
- Pages
- 1665-1671
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2056891542
- Cited by
- 63
- References
- 14
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 2 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 3 · 2014: 1 · 2013: 4 · 2012: 2
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- superconducting magnets, Penning trap mass spectrometer, magnetic field stability, cryostat design, Helmholtz coil, temperature stabilization, high-resolution mass spectrometry, carbon ions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.