The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Phase-contrast microtomography with coherent high-energy synchrotron x rays
Abstract
Cross-sectional information on low electron density materials can be obtained by probing a sample with a 60 keV coherent synchrotron x-ray beam in an in-line holography setup. Such objects are practically transparent to high energy x rays and create a phase shift of the wave front only. Images of a 100 μm diameter boron fiber were recorded in the extreme near field region, where contrast occurs only at interfaces between regions with different decrements of refractive index. Theoretical simulations are in good agreement with the measured intensities. In a tomographic reconstruction the 15 μm diameter core of the fiber is clearly visible, demonstrating the possibility of reconstructing three dimensional interfaces between low density materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Cited by
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997) · Journal of Applied Physics · doi:10.1063/1.364374 · Cited by 538
Contrast and resolution in imaging with a microfocus x-ray source
Pogany, A., Gao, D., & Wilkins, S. W. (1997) · Review of Scientific Instruments · doi:10.1063/1.1148194 · Cited by 476
Dynamical Theory of X-Ray Diffraction
Authier, A. (2003) · doi:10.1093/acprof:oso/9780198528920.001.0001 · Cited by 331
A synchrotron radiation microtomography system for the analysis of trabecular bone samples
Salomé, M., Peyrin, F., Cloetens, P., Odet, C., Laval-Jeantet, A.-M., Baruchel, J., & Spanne, P. (1999) · Medical Physics · doi:10.1118/1.598736 · Cited by 275
Self-citation
Metadata
- Authors
- Raven, C., Snigirev, A., Snigireva, I., Spanne, P., Souvorov, A., & Kohn, V.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1996-09-23
- Volume
- 69
- Issue
- 13
- Pages
- 1826-1828
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2057918994
- Cited by
- 158
- References
- 1
- FWCI
- 13.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phase-contrast microtomography with coherent high-energy synchrotron x rays. https://app.cochat.ai/papers/10.1063/1.117446
- The paper
- Raven, C., Snigirev, A., Snigireva, I., Spanne, P., Souvorov, A., & Kohn, V. (1996). Phase-contrast microtomography with coherent high-energy synchrotron x rays. Applied Physics Letters. https://doi.org/10.1063/1.117446
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.