The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Abstract
The novel possibilities of phase feature detection in radiography at a third generation synchrotron radiation source are used to image, both in projection and in computed tomography, a cracked silicon single crystal and metal matrix composites strained in tension. Through an instrumentally very simple technique, based on Fresnel diffraction, phase jumps related to the interface between the matrix and the reinforcing phases of the composites are detected even when these phases show very similar x-ray attenuation. Strain-induced cracks with openings below the micrometer range are also visible through the phase modulation they introduce, illustrating the potential of the technique for assessing damage in materials with improved resolution and sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Surface Studies of Solids by Total Reflection of X-Rays
Parratt, L. G. (1954) · Physical Review · doi:10.1103/physrev.95.359 · Cited by 5,188
Elementary engineering fracture mechanics
Broek, D. (1982) · Springer eBooks · doi:10.1007/978-94-009-4333-9 · Cited by 2,894
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
Image Reconstruction from Projections
(2004) · Biomedical Engineering · doi:10.1201/9780203492543.ch9 · Cited by 915
Phase objects in synchrotron radiation hard x-ray imaging
Cloetens, P., Barrett, R., Baruchel, J., Guigay, J.-P., & Schlenker, M. (1996) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/29/1/023 · Cited by 853
Self-citationX-ray plane-wave topography observation of the phase contrast from a non-crystalline object
Ingal, V. N., & Beliaevskaya, E. A. (1995) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/28/11/012 · Cited by 411
AN X-RAY INTERFEROMETER WITH LONG SEPARATED INTERFERING BEAM PATHS
Bonse, U., & Hart, M. (1965) · Applied Physics Letters · doi:10.1063/1.1754330 · Cited by 178
Cited by
Tafforeau, P., Boistel, R., Boller, E., Bravin, A., Brunet, M., Chaimanee, Y., Cloetens, P., Feist, M., Hoszowska, J., Jaeger, J.-J., et al. (2006) · Applied Physics A · doi:10.1007/s00339-006-3507-2 · Cited by 456
Self-citationAdvantages of phase retrieval for fast x-ray tomographic microscopy
Mokso, R., Marone, F., Irvine, S., Nyvlt, M., Schwyn, D., Mader, K., Taylor, G. K., Krapp, H. G., Skeren, M., & Stampanoni, M. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/49/494004 · Cited by 56
Metadata
- Authors
- Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1997-05-01
- Volume
- 81
- Issue
- 9
- Pages
- 5878-5886
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2050757502
- Cited by
- 538
- References
- 11
- FWCI
- 14.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Observation of microstructure and damage in materials by phase sensitive radiography and tomography. https://app.cochat.ai/papers/10.1063/1.364374
- The paper
- Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997). Observation of microstructure and damage in materials by phase sensitive radiography and tomography. Journal of Applied Physics. https://doi.org/10.1063/1.364374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.