The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
A synchrotron radiation microtomography system for the analysis of trabecular bone samples
Abstract
X-ray computed microtomography is particularly well suited for studying trabecular bone architecture, which requires three-dimensional (3-D) images with high spatial resolution. For this purpose, we describe a three-dimensional computed microtomography (microCT) system using synchrotron radiation, developed at ESRF. Since synchrotron radiation provides a monochromatic and high photon flux x-ray beam, it allows high resolution and a high signal-to-noise ratio imaging. The principle of the system is based on truly three-dimensional parallel tomographic acquisition. It uses a two-dimensional (2-D) CCD-based detector to record 2-D radiographs of the transmitted beam through the sample under different angles of view. The 3-D tomographic reconstruction, performed by an exact 3-D filtered backprojection algorithm, yields 3-D images with cubic voxels. The spatial resolution of the detector was experimentally measured. For the application to bone investigation, the voxel size was set to 6.65 microm, and the experimental spatial resolution was found to be 11 microm. The reconstructed linear attenuation coefficient was calibrated from hydroxyapatite phantoms. Image processing tools are being developed to extract structural parameters quantifying trabecular bone architecture from the 3-D microCT images. First results on human trabecular bone samples are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Phase objects in synchrotron radiation hard x-ray imaging
Cloetens, P., Barrett, R., Baruchel, J., Guigay, J.-P., & Schlenker, M. (1996) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/29/1/023 · Cited by 853
Self-citationThree-Dimensional X-Ray Microtomography
Flannery, B. P., Deckman, H. W., Roberge, W. G., & D'Amico, K. L. (1987) · Science · doi:10.1126/science.237.4821.1439 · Cited by 773
Trabecular bone architecture in the pathogenesis and prevention of fracture
Parfitt, A. M. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90274-9 · Cited by 351
Optimum energies for x-ray transmission tomography of small samples
Grodzins, L. (1983) · Nuclear Instruments and Methods in Physics Research · doi:10.1016/0167-5087(83)90393-9 · Cited by 252
Muller, R., Hildebrand, T., & Ruegsegger, P. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/1/009 · Cited by 245
X-Ray Tomographic Microscopy (XTM) Using Synchrotron Radiation
Kinney, J. H., & Nichols, M. C. (1992) · Annual Review of Materials Science · doi:10.1146/annurev.ms.22.080192.001005 · Cited by 245
In vivo, three-dimensional microscopy of trabecular bone
Dr. Kinney, J. H., Lane, N. E., & Haupt, D. L. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100213 · Cited by 230
Cited by
High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Sansalone, V., Naili, S., Bousson, V., Bergot, C., Peyrin, F., Zarka, J., Laredo, J. D., & Haïat, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.034 · Cited by 109
Self-citation
Metadata
- Authors
- Salomé, M., Peyrin, F., Cloetens, P., Odet, C., Laval-Jeantet, A.-M., Baruchel, J., & Spanne, P.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1999-10
- Volume
- 26
- Issue
- 10
- Pages
- 2194-2204
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2033375557
- Cited by
- 275
- References
- 18
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A synchrotron radiation microtomography system for the analysis of trabecular bone samples. https://app.cochat.ai/papers/10.1118/1.598736
- The paper
- Salomé, M., Peyrin, F., Cloetens, P., Odet, C., Laval-Jeantet, A.-M., Baruchel, J., & Spanne, P. (1999). A synchrotron radiation microtomography system for the analysis of trabecular bone samples. Medical Physics. https://doi.org/10.1118/1.598736
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.