CoChat

Fluorescence lifetime three-dimensional microscopy with picosecond precision using a multifocal multiphoton microscope

Straub, M., Hell, S. W. · 1998 · Applied Physics Letters
Cited by 138

The DOI matches its Crossref record.

Abstract

The combination of pulsed-mode excitation multifocal multiphoton microscopy with a high-repetition, time-gated intensified CCD camera enables efficient three-dimensional (3D) fluorescence lifetime imaging. With a 200-ps gate opening at 76 MHz repetition rate, fluorescence decay can be traced in a sequence of images with varying delays between pulse and gate. Fluorophore lifetimes are measured with a precision of a few picoseconds. As an application we show that, upon two-photon excitation at 800 nm, certain pollen samples feature a multiexponential fluorescence relaxation. Our results indicate that efficient four-dimensional microscopy with hundreds of nanometer spatial and tens of picoseconds temporal resolution is within reach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.122276

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 138

Metadata

Authors
Straub, M., & Hell, S. W.
Venue
Applied Physics Letters
Published
1998-09-28
Volume
73
Issue
13
Pages
1769-1771
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W1993272328
Cited by
138
References
0
FWCI
8.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fluorescence lifetime three-dimensional microscopy with picosecond precision using a multifocal multiphoton microscope. https://app.cochat.ai/papers/10.1063/1.122276
The paper
Straub, M., & Hell, S. W. (1998). Fluorescence lifetime three-dimensional microscopy with picosecond precision using a multifocal multiphoton microscope. Applied Physics Letters. https://doi.org/10.1063/1.122276

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.