The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Experimental and theoretical scaling laws for transverse diffusive broadening in two-phase laminar flows in microchannels
Abstract
This letter quantifies both experimentally and theoretically the diffusion of low-molecular-weight species across the interface between two aqueous solutions in pressure-driven laminar flow in microchannels at high Péclet numbers. Confocal fluorescent microscopy was used to visualize a fluorescent product formed by reaction between chemical species carried separately by the two solutions. At steady state, the width of the reaction–diffusion zone at the interface adjacent to the wall of the channel and transverse to the direction of flow scales as the one-third power of both the axial distance down the channel (from the point where the two streams join) and the average velocity of the flow, instead of the more familiar one-half power scaling which was measured in the middle of the channel. A quantitative description of reaction–diffusion processes near the walls of the channel, such as described in this letter, is required for the rational use of laminar flows for performing spatially resolved surface chemistry and biology inside microchannels and for understanding three-dimensional features of mass transport in shearing flows near surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Self-citationLaminar Flow Forced Convection in Ducts
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-06152-x · Cited by 2,837
Life in Moving Fluids: The Physical Biology of Flow - Revised and Expanded Second Edition
Vogel, S. (1983) · Princeton University Press eBooks · doi:10.1515/9780691212975 · Cited by 1,111
Microfabrication Inside Capillaries Using Multiphase Laminar Flow Patterning
Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Science · doi:10.1126/science.285.5424.83 · Cited by 659
Self-citationQuantitative Analysis of Molecular Interaction in a Microfluidic Channel: The T-Sensor
Kamholz, A. E., Weigl, B. H., Finlayson, B. A., & Yager, P. (1999) · Analytical Chemistry · doi:10.1021/ac990504j · Cited by 631
Patterning cells and their environments using multiple laminar fluid flows in capillary networks
Takayama, S., McDonald, J. C., Ostuni, E., Liang, M. N., Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.10.5545 · Cited by 528
Self-citationMicrofluidic Diffusion-Based Separation and Detection
Weigl, B. H., & Yager, P. (1999) · Science · doi:10.1126/science.283.5400.346 · Cited by 502
Pollack, L., Tate, M. W., Darnton, N. C., Knight, J. B., Gruner, S. M., Eaton, W. A., & Austin, R. H. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10115 · Cited by 285
Blatter, L. A., & Wier, W. G. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82494-2 · Cited by 176
Modular concept of a laboratory on a chip for chemical and biochemical analysis
Blankenstein, G., & Larsen, U. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00109-7 · Cited by 158
Zimmer, C. (1999) · Science · doi:10.1126/science.284.5411.83 · Cited by 137
Ehrfeld, W., Hessel, V., & Lehr, H. (1998) · Topics in current chemistry · doi:10.1007/3-540-69544-3_10 · Cited by 51
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Self-citationSoft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationPoly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Self-citationMicro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Metadata
- Authors
- Ismagilov, R. F., Stroock, A. D., Kenis, P. J. A., Whitesides, G., & Stone, H. A.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2000-04-24
- Volume
- 76
- Issue
- 17
- Pages
- 2376-2378
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2041402624
- Cited by
- 540
- References
- 12
- FWCI
- 13.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.