The DOI matches its Crossref record.
Nitrogen dioxide and kerosene-flame soot calibration of photoacoustic instruments for measurement of light absorption by aerosols
Abstract
A nitrogen dioxide calibration method is developed to evaluate the theoretical calibration for a photoacoustic instrument used to measure light absorption by atmospheric aerosols at a laser wavelength of 532.0 nm. This method uses high concentrations of nitrogen dioxide so that both a simple extinction and the photoacoustically obtained absorption measurement may be performed simultaneously. Since Rayleigh scattering is much less than absorption for the gas, the agreement between the extinction and absorption coefficients can be used to evaluate the theoretical calibration, so that the laser gas spectra are not needed. Photoacoustic theory is developed to account for strong absorption of the laser beam power in passage through the resonator. Findings are that the photoacoustic absorption based on heat-balance theory for the instrument compares well with absorption inferred from the extinction measurement, and that both are well within values represented by published spectra of nitrogen dioxide. Photodissociation of nitrogen dioxide limits the calibration method to wavelengths longer than 398 nm. Extinction and absorption at 532 and 1047 nm were measured for kerosene-flame soot to evaluate the calibration method, and the single scattering albedo was found to be 0.31 and 0.20 at these wavelengths, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Visibility: Science and Regulation
Watson, J. G. (2002) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2002.10470813 · Cited by 929
Aerosol light absorption and its measurement: A review
Moosmüller, H., Chakrabarty, R. K., & Arnott, W. P. (2009) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2009.02.035 · Cited by 867
Self-citationOptical properties of humic-like substances (HULIS) in biomass-burning aerosols
Hoffer, A., Gelencsér, A., Guyon, P., Kiss, G., Schmid, O., Frank, G. P., Artaxo, P., & Andreae, M. O. (2006) · Atmospheric Chemistry and Physics · doi:10.5194/acp-6-3563-2006 · Cited by 615
Arnott, W. P., Hamasha, K., Moosmüller, H., Sheridan, P. J., & Ogren, J. A. (2005) · Aerosol Science and Technology · doi:10.1080/027868290901972 · Cited by 598
Self-citationKerosene: A Review of Household Uses and their Hazards in Low- and Middle-Income Countries
Lam, N. L., Smith, K. R., Gauthier, A., & Bates, M. N. (2012) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937404.2012.710134 · Cited by 443
Metadata
- Authors
- Arnott, W. P., Moosmüller, H., & Walker, J. W.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2000-12-01
- Volume
- 71
- Issue
- 12
- Pages
- 4545-4552
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2030904318
- Cited by
- 165
- References
- 0
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nitrogen dioxide and kerosene-flame soot calibration of photoacoustic instruments for measurement of light absorption by aerosols. https://app.cochat.ai/papers/10.1063/1.1322585
- The paper
- Arnott, W. P., Moosmüller, H., & Walker, J. W. (2000). Nitrogen dioxide and kerosene-flame soot calibration of photoacoustic instruments for measurement of light absorption by aerosols. Review of Scientific Instruments. https://doi.org/10.1063/1.1322585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.