The DOI matches its Crossref record.
Surface effects and high quality factors in ultrathin single-crystal silicon cantilevers
Open accessAbstract
Surface effects in ultrathin single-crystal silicon cantilevers of 170 nm thickness, which are optically actuated mainly by the light pressure effect, are investigated under ultrahigh vacuum (UHV) condition. Annealing the cantilevers at 1000 °C for 30 s in UHV results in an over 1 order of magnitude increase of the quality factor (Q factor), up to about 2.5×105 for cantilevers of 30–90 μm in length. The improvement of Q factor was found to be associated with the deoxidization of the surface, as determined by x-ray photoelectron spectroscopy. These results suggest that the surface effects in the ultrathin cantilevers dominate their mechanical behavior. With the promising mechanical behavior, the cantilever can be easily actuated by a laser beam (beam size: about 300×100 μm2) with power down to less than 40 μW at a wavelength of 680 nm, corresponding to 480 nW, i.e., 1.64×1012 photons/s, irradiated on the cantilever surface (60×6 μm2). This provides a rather simple way to operate the ultrathin cantilevers dynamically in UHV. Atomic scale force resolution (4.8×10−17 N) at 300 K is also expected with these cantilevers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ekinci, K. L., & Roukes, M. L. (2005) · Review of Scientific Instruments · doi:10.1063/1.1927327 · Cited by 1,374
Towards quantum superpositions of a mirror
Marshall, W., Simon, C., Penrose, R., & Bouwmeester, D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.130401 · Cited by 960
Cavity cooling of a microlever
Metzger, C. H., & Karrai, K. (2004) · Nature · doi:10.1038/nature03118 · Cited by 677
Nanometre-scale displacement sensing using a single electron transistor
Knobel, R. G., & Cleland, A. N. (2003) · Nature · doi:10.1038/nature01773 · Cited by 599
Sub-attonewton force detection at millikelvin temperatures
Mamin, H. J., & Rugar, D. (2001) · Applied Physics Letters · doi:10.1063/1.1418256 · Cited by 439
Intrinsic dissipation in high-frequency micromechanical resonators
Mohanty, P., Harrington, D. A., Ekinci, K. L., Yang, Y. T., Murphy, M. J., & Roukes, M. L. (2002) · Physical Review B · doi:10.1103/physrevb.66.085416 · Cited by 312
Dissipation in nanoelectromechanical systems
Imboden, M., & Mohanty, P. (2014) · Physics Reports · doi:10.1016/j.physrep.2013.09.003 · Cited by 273
Temperature Dependence of Quality Factor in MEMS Resonators
Kim, B., Hopcroft, M. A., Candler, R. N., Jha, C. M., Agarwal, M., Melamud, R., Chandorkar, S. A., Yama, G., & Kenny, T. W. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.924253 · Cited by 268
Metadata
- Authors
- Yang, J., Ono, T., & Esashi, M.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2000-12-04
- Volume
- 77
- Issue
- 23
- Pages
- 3860-3862
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2014035322
- Cited by
- 171
- References
- 0
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.