The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Temperature Dependence of Quality Factor in MEMS Resonators
Abstract
The temperature dependence of the quality factor of microelectromechanical system (MEMS) resonators is analyzed and measured. For silicon MEMS resonators, there are several energy loss mechanisms that determine the quality factor. These include air-damping, thermoelastic dissipation, and anchor and surface losses. For resonators operating at a low pressure in hermetic wafer-scale encapsulation, the effect of each energy loss mechanism is discussed. The temperature dependence of each mechanism and their contribution to the total quality factor is investigated. MEMS resonators can be designed to have either strong or weak dependence of on temperature, which is if the effects of the temperature on the dominant loss mechanisms are well understood. The sensitivity of up to 1% changes in quality factor per degree Celsius change of temperature was demonstrated by experiment. By using as the thermometer for temperature compensation, a preliminary experiment demonstrated less than 4-ppm resonant frequency variation over the 0 -70 temperature range. This indicates that the quality factor can be used as an absolute intrinsic thermometer for temperature compensation in the MEMS resonators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Solid State Physics
Kittel, C., & Fan, H. Y. (1957) · American Journal of Physics · doi:10.1119/1.1934457 · Cited by 22,240
Introduction to solid state physics
(1956) · Journal of the Franklin Institute · doi:10.1016/0016-0032(56)90703-7 · Cited by 7,151
Thermal Conductivity of Silicon and Germanium from 3°K to the Melting Point
Glassbrenner, C. J., & Slack, G. A. (1964) · Physical Review · doi:10.1103/physrev.134.a1058 · Cited by 1,652
Thermoelastic damping in micro- and nanomechanical systems
Lifshitz, R., & Roukes, M. L. (2000) · Physical review. B, Condensed matter · doi:10.1103/physrevb.61.5600 · Cited by 1,231
Okada, Y., & Tokumaru, Y. (1984) · Journal of Applied Physics · doi:10.1063/1.333965 · Cited by 1,215
Internal Friction in Solids II. General Theory of Thermoelastic Internal Friction
Zener, C. (1938) · Physical Review · doi:10.1103/physrev.53.90 · Cited by 779
Quality factors in micron- and submicron-thick cantilevers
Yasumura, K. Y., Stowe, T. D., Chow, E. M., Pfafman, T. E., Kenny, T. W., Stipe, B. C., & Rugar, D. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825786 · Cited by 688
Self-citationFlubacher, P., Leadbetter, A. J., & Morrison, J. A. (1959) · Philosophical Magazine · doi:10.1080/14786435908233340 · Cited by 359
Engineering MEMS Resonators With Low Thermoelastic Damping
Duwel, A., Candler, R. N., Kenny, T. W., & Varghese, M. K. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.883573 · Cited by 251
Self-citationCandler, R. N., Hopcroft, M. A., Kim, B., Park, W.-T., Melamud, R., Agarwal, M., Yama, G., Partridge, A., Lutz, M., & Kenny, T. W. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.883586 · Cited by 207
Self-citation
Cited by
What is the Young's Modulus of Silicon?
Hopcroft, M. A., Nix, W. D., & Kenny, T. W. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2039697 · Cited by 2,119
Self-citation
Metadata
- Authors
- Kim, B., Hopcroft, M. A., Candler, R. N., Jha, C. M., Agarwal, M., Melamud, R., Chandorkar, S. A., Yama, G., & Kenny, T. W.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2008-06
- Volume
- 17
- Issue
- 3
- Pages
- 755-766
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2127490754
- Cited by
- 268
- References
- 14
- FWCI
- 8.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature Dependence of Quality Factor in MEMS Resonators. https://app.cochat.ai/papers/10.1109/jmems.2008.924253
- The paper
- Kim, B., Hopcroft, M. A., Candler, R. N., Jha, C. M., Agarwal, M., Melamud, R., Chandorkar, S. A., Yama, G., & Kenny, T. W. (2008). Temperature Dependence of Quality Factor in MEMS Resonators. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2008.924253
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.