The extended surface forces apparatus. Part I. Fast spectral correlation interferometry
The DOI matches its Crossref record.
Abstract
This article describes details of the operation and performance of fast spectral correlation interferometry, which allows for considerably improved operation of the surface forces apparatus. Up to 150 interference fringes can be simultaneously tracked over a wide spectral range, leading to considerably more precise and simultaneous extraction of multiple optical quantities, over a greatly extended distance range. When used for surface-separation measurement, a precision of 25 pm is readily achievable over a distance ranging from 0 to >10 μm. Data acquisition rates are also considerably improved, allowing for dynamic measurements. Automated actuation of optical deflectors introduces a multidimensional scanning capability to the optical probe with a lateral resolution of 1 μm. The entire process is computer controlled and features unattended batch processing of complex measurements. This publication illustrates experimental setup, methodology, measurements, and detailed error calculation for a selection of practically relevant situations in the extended surface forces apparatus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in the surface forces apparatus (SFA) technique
Israelachvili, J., Min, Y., Akbulut, M., Alig, A., Carver, G., Greene, W., Kristiansen, K., Meyer, E., Pesika, N., Rosenberg, K., et al. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/3/036601 · Cited by 578
Zappone, B., Ruths, M., Greene, G. W., Jay, G. D., & Israelachvili, J. N. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.088799 · Cited by 341
Fundamental Aspects of Energy Dissipation in Friction
Park, J. Y., & Salmeron, M. (2014) · Chemical Reviews · doi:10.1021/cr200431y · Cited by 272
Hydrated-ion ordering in electrical double layers
Espinosa-Marzal, R. M., Drobek, T., Balmer, T., & Heuberger, M. P. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp40255f · Cited by 88
Self-citationStepwise collapse of highly overlapping electrical double layers
Zachariah, Z., Espinosa-Marzal, R. M., Spencer, N. D., & Heuberger, M. P. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c6cp04222h · Cited by 37
Self-citation
Metadata
- Authors
- Heuberger, M.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2001-03-01
- Volume
- 72
- Issue
- 3
- Pages
- 1700-1707
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2056330904
- Cited by
- 141
- References
- 0
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The extended surface forces apparatus. Part I. Fast spectral correlation interferometry. https://app.cochat.ai/papers/10.1063/1.1347978
- The paper
- Heuberger, M. (2001). The extended surface forces apparatus. Part I. Fast spectral correlation interferometry. Review of Scientific Instruments. https://doi.org/10.1063/1.1347978
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.