The DOI matches its Crossref record.
Fabrication of <5 nm width lines in poly(methylmethacrylate) resist using a water:isopropyl alcohol developer and ultrasonically-assisted development
Abstract
We report on the fabrication of 3–4 nm wide continuous lines in a positive tone electron beam resist poly(methylmethacrylate) on a solid substrate. This narrow linewidth was made possible through the use of a nonsolvent-based developer system, water:isopropyl alcohol, together with ultrasonically-assisted development, which reduced the effective development time thus limiting the swelling of the unexposed resist. This combination of solvent system and development technique results in a smaller radius of gyration in the developing polymer molecules and in a wider exposure dose latitude compared to conventional processing and so allows ultrasmall features to be reproduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New Approaches to Nanofabrication: Molding, Printing, and Other Techniques
Gates, B. D., Xu, Q., Stewart, M., Ryan, D., Willson, C. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr030076o · Cited by 2,020
Production and processing of graphene and 2d crystals
Bonaccorso, F., Lombardo, A., Hasan, T., Sun, Z., Colombo, L., & Ferrari, A. C. (2012) · Materials Today · doi:10.1016/s1369-7021(13)70014-2 · Cited by 1,057
Soft X-ray microscopy at a spatial resolution better than 15 nm
Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H., & Attwood, D. T. (2005) · Nature · doi:10.1038/nature03719 · Cited by 851
Influence of nanoscale surface topography on protein adsorption and cellular response
Lord, M. S., Foss, M., & Besenbacher, F. (2010) · Nano Today · doi:10.1016/j.nantod.2010.01.001 · Cited by 604
Lim, J. Y., & Donahue, H. J. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0154 · Cited by 534
Resists for sub-20-nm electron beam lithography with a focus on HSQ: state of the art
Grigorescu, A. E., & Hagen, C. W. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/29/292001 · Cited by 422
Nanofluidic Devices and Their Applications
Abgrall, P., & Nguyen, N. T. (2008) · Analytical Chemistry · doi:10.1021/ac702296u · Cited by 383
Radiation Chemistry in Chemically Amplified Resists
Kozawa, T., & Tagawa, S. (2010) · Japanese Journal of Applied Physics · doi:10.1143/jjap.49.030001 · Cited by 360
Hydrocarbon lithography on graphene membranes
Meyer, J. C., Girit, C. O., Crommie, M. F., & Zettl, A. (2008) · Applied Physics Letters · doi:10.1063/1.2901147 · Cited by 282
Disorder in convergent floral nanostructures enhances signalling to bees
Moyroud, E., Wenzel, T., Middleton, R., Rudall, P. J., Banks, H., Reed, A., Mellers, G., Killoran, P., Westwood, M. M., Steiner, U., et al. (2017) · Nature · doi:10.1038/nature24285 · Cited by 170
Rahman, F., Carbaugh, D. J., Wright, J. T., Rajan, P., Pandya, S. G., & Kaya, S. (2020) · Microelectronic Engineering · doi:10.1016/j.mee.2020.111238 · Cited by 79
Metadata
- Authors
- Yasin, S., Hasko, D. G., & Ahmed, H.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2001-04-30
- Volume
- 78
- Issue
- 18
- Pages
- 2760-2762
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2012202734
- Cited by
- 164
- References
- 0
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.