A high-density multichannel surface electromyography system for the characterization of single motor units
The DOI matches its Crossref record.
Abstract
An electromyography (EMG) system is presented that noninvasively records the electrical activity of a muscle with 126 densely spaced skin-surface electrodes. The electrodes are arranged in a two-dimensional array and integrated in a single container for ease of application. Signals are recorded “monopolarly”, with a reference electrode placed at a distance from the array. With this recording configuration, the surface EMG (sEMG) potential distribution can be described not only as a function of time, but also topographically. The availability of topographical information opens up a range of applications. Some of these have been described previously. However, the system presented is unique in that it allows exploration of all clinical and scientific possibilities of topographical sEMG. In its design, special attention was paid to user-friendliness and flexibility. With high-density multichannel sEMG, both the properties of a whole muscle and those of single motor units, the functional units of a muscle, can be studied. The latter belong to a realm that was long considered accessible only with needle-EMG, a conventional, invasive diagnostic technique. It is demonstrated that the additional topographical information can be used to characterize motor units in a way that is partially superior to needle EMG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589
Heckman, C. J., & Enoka, R. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100087 · Cited by 414
Decoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383
“These ‘‘high-density surface EMG” systems (Blok et al., 2002; Merletti et al., 2008) comprise several, closely spaced surface electrodes.”
BackgroundMethodological aspects of SEMG recordings for force estimation – A tutorial and review
Staudenmann, D., Roeleveld, K., Stegeman, D. F., & van Dieën, J. H. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.08.005 · Cited by 379
Self-citationSurface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Analysis of motor units with high-density surface electromyography
Merletti, R., Holobar, A., & Farina, D. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.002 · Cited by 350
Estimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318
“There have been substantial efforts in the development of methods for the decomposition of sEMG recorded with high-density electrode grids (Blok et al., 2002; Gazzoni et al., 2004; Kleine et al., 2007; Wood et al., 2001).”
MethodClinical applications of high-density surface EMG: A systematic review
Drost, G., Stegeman, D. F., van Engelen, B. G. M., & Zwarts, M. J. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.09.005 · Cited by 311
Self-citationMultichannel surface EMG: Basic aspects and clinical utility
Zwarts, M. J., & Stegeman, D. F. (2003) · Muscle & Nerve · doi:10.1002/mus.10358 · Cited by 302
Self-citationThe linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285
“Other application areas concern monitoring of muscle reinnervation following peripheral lesions [58] or limb transplant, MU topography [59], studies of innervation of the anal and urethral sphincters to provide guidelines during surgical procedures of the pelvic floor or during delivery [11].”
BackgroundSurface EMG in Clinical Assessment and Neurorehabilitation: Barriers Limiting Its Use
Campanini, I., Disselhorst-Klug, C., Rymer, W. Z., & Merletti, R. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00934 · Cited by 270
Standards for quantification of EMG and neurography
Stålberg, E., van Dijk, H., Falck, B., Kimura, J., Neuwirth, C., Pitt, M., Podnar, S., Rubin, D. I., Rutkove, S., Sanders, D. B., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.05.008 · Cited by 254
Self-citationA review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
Expectancy Induces Dynamic Modulation of Corticospinal Excitability
van Elswijk, G., Kleine, B. U., Overeem, S., & Stegeman, D. F. (2007) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2007.19.1.121 · Cited by 101
Self-citation
Metadata
- Authors
- Blok, J. H., van Dijk, J. P., Drost, G., Zwarts, M. J., & Stegeman, D. F.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2002-04-01
- Volume
- 73
- Issue
- 4
- Pages
- 1887-1897
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2010531654
- Cited by
- 116
- References
- 0
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.