The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tip motion in amplitude modulation (tapping-mode) atomic-force microscopy: Comparison between continuous and point-mass models
Open accessAbstract
We discuss the influence of high-order frequency components in the operation of an amplitude modulation atomic-force microscope (AFM). A comparative study of point-mass and continuous models is performed to describe the tip motion. The tip–surface interaction force excites high-order frequency components whenever a higher harmonic of the excitation force is close to an eigenmode of the cantilever beam. The strength of those components depends on the set point amplitude and the fundamental resonance frequency of the cantilever. However, for standard operating conditions with quality factors in the 102–103 range, higher-order components are about three orders of magnitude smaller than the component at the excitation frequency. We conclude that point-mass models are suitable to describe the operation of a tapping-mode AFM in air environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Cited by
The emergence of multifrequency force microscopy
Garcia, R., & Herruzo, E. T. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.38 · Cited by 577
An atomic force microscope tip designed to measure time-varying nanomechanical forces
Sahin, O., Magonov, S., Su, C., Quate, C. F., & Solgaard, O. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.226 · Cited by 481
Garcia, R. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00318b · Cited by 480
Identification of Nanoscale Dissipation Processes by Dynamic Atomic Force Microscopy
Garcia, R., Gómez, C. J., Martinez, N. F., Patil, S., Dietz, C., & Magerle, R. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.016103 · Cited by 310
Capillary forces in tapping mode atomic force microscopy
Zitzler, L., Herminghaus, S., & Mugele, F. (2002) · Physical Review B · doi:10.1103/physrevb.66.155436 · Cited by 305
Metadata
- Authors
- Rodrı́guez, T. R., & Garcı́a, R.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2002-03-04
- Volume
- 80
- Issue
- 9
- Pages
- 1646-1648
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1965867113
- Cited by
- 190
- References
- 1
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tip motion in amplitude modulation (tapping-mode) atomic-force microscopy: Comparison between continuous and point-mass models. https://app.cochat.ai/papers/10.1063/1.1456543
- The paper
- Rodrı́guez, T. R., & Garcı́a, R. (2002). Tip motion in amplitude modulation (tapping-mode) atomic-force microscopy: Comparison between continuous and point-mass models. Applied Physics Letters. https://doi.org/10.1063/1.1456543
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.