The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Capillary forces in tapping mode atomic force microscopy
Open accessAbstract
We investigated the influence of the relative humidity on amplitude and phase of the cantilever oscillation while operating an atomic force microscope (AFM) in the tapping mode. If the free oscillation amplitude ${A}_{0}$ exceeds a certain critical amplitude ${A}_{c},$ the amplitude- and phase-distance curves show a transition from a regime with a net attractive force between tip and sample to a net repulsive regime. For hydrophilic tip and sample this critical amplitude ${A}_{c}$ is found to increase with increasing relative humidity. In contrast, no such dependence was found for hydrophobic samples. Numerical simulations show that this behavior can be explained by assuming the intermittent formation and rupture of a capillary neck in each oscillation cycle of the AFM cantilever.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of contact deformations on the adhesion of particles
Derjaguin, B. V., Muller, V. M., & Toporov, Y. P. (1975) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(75)90018-1 · Cited by 4,589
Energy dissipation in tapping-mode atomic force microscopy
Cleveland, J. P., Anczykowski, B., Schmid, A. E., & Elings, V. B. (1998) · Applied Physics Letters · doi:10.1063/1.121434 · Cited by 881
Attractive and repulsive tip-sample interaction regimes in tapping-mode atomic force microscopy
García, R., & San Paulo, A. (1999) · Physical Review B · doi:10.1103/physrevb.60.4961 · Cited by 570
Investigation of Humidity-Dependent Capillary Force
Xiao, X., & Qian, L. (2000) · Langmuir · doi:10.1021/la000770o · Cited by 472
Swelling effects in lithium fluoride induced by swift heavy ions
Trautmann, 1., Toulemonde, M., Costantini, J. M., Grob, J. J., & Schwartz, K. (2000) · Physical Review B · doi:10.1103/physrevb.62.13 · Cited by 380
Bar, G., Thomann, Y., Brandsch, R., Cantow, H.-J., & Whangbo, M.-H. (1997) · Langmuir · doi:10.1021/la970091m · Cited by 324
S URFACE B IOLOGY OF DNA BY A TOMIC F ORCE M ICROSCOPY
Hansma, H. G. (2001) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.52.1.71 · Cited by 279
Gaining control of pattern formation of dewetting liquid films
Seemann, R., Herminghaus, S., & Jacobs, K. (2001) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/13/21/319 · Cited by 266
Self-citationBurnham, N. A., Behrend, O. P., Oulevey, F., Gremaud, G., Gallo, P.-J., Gourdon, D., Dupas, E., Kulik, A. J., Pollock, H. M., & Briggs, G. A. D. (1997) · Nanotechnology · doi:10.1088/0957-4484/8/2/004 · Cited by 265
Cantilever dynamics in quasinoncontact force microscopy: Spectroscopic aspects
Anczykowski, B., Krüger, D., & Fuchs, H. (1996) · Physical review. B, Condensed matter · doi:10.1103/physrevb.53.15485 · Cited by 256
Cited by
Molecular Structure of Water at Interfaces: Wetting at the Nanometer Scale
Verdaguer, A., Sacha, G. M., Bluhm, H., & Salmeron, M. (2006) · Chemical Reviews · doi:10.1021/cr040376l · Cited by 627
Metadata
- Authors
- Zitzler, L., Herminghaus, S., & Mugele, F.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 2002-10-31
- Volume
- 66
- Issue
- 15
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W2049592940
- Cited by
- 305
- References
- 21
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary forces in tapping mode atomic force microscopy. https://app.cochat.ai/papers/10.1103/physrevb.66.155436
- The paper
- Zitzler, L., Herminghaus, S., & Mugele, F. (2002). Capillary forces in tapping mode atomic force microscopy. Physical Review B. https://doi.org/10.1103/physrevb.66.155436
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.