The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Comparative experimental study of ionic polymer–metal composites with different backbone ionomers and in various cation forms
Abstract
An ionic polymer–metal composite (IPMC) consisting of a thin perfluorinated ionomer (usually, Nafion or Flemion) strip, platinum, and/or gold plated on both faces and neutralized by a certain amount of appropriate cations undergoes large bending motion when, in a hydrated state, a small electric field is applied across its thickness. When the same membrane is suddenly bent, a small voltage of the order of millivolts is produced across its surfaces. Hence IPMCs can serve as soft bending actuators and sensors. This coupled electrical–chemical–mechanical response of IPMCs depends on the structure of the backbone ionic polymer, the morphology and conductivity of the metal electrodes, the nature of the cations, and the level of hydration (or other solvent uptake). We have carried out extensive experimental studies on both Nafion- and Flemion-based IPMCs in various cation forms, seeking to understand the fundamental properties of these composites, to explore the mechanism of their actuation, and finally, to optimize their performance for various potential applications. The results of some of these tests on both Nafion- and Flemion-based IPMCs with alkali-metal or alkyl-ammonium cations are reported here. Compared with Nafion-based IPMCs, Flemion-based IPMCs with fine dendritic gold electrodes have higher ion-exchange capacity, better surface conductivity, higher hydration capacity, and higher longitudinal stiffness. They also display greater bending actuation under the same applied voltage. In addition, they do not display a reverse relaxation under a sustained dc voltage, which is typical of Nafion-based IPMCs in alkali-metal form. Flemion IPMCs thus are promising composites for application as bending actuators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electroactive polymer (EAP) actuators as artificial muscles : reality, potential, and challenges
Bar‐Cohen, Y. (2001) · Medical Entomology and Zoology · Cited by 1,177
Ionic polymer-metal composites: I. Fundamentals
Shahinpoor, M., & Kim, K. J. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/4/327 · Cited by 1,126
Ion transport and clustering in nafion perfluorinated membranes
Hsu, W. Y., & Gierke, T. D. (1983) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)81563-x · Cited by 973
Recent advances in perfluorinated ionomer membranes: structure, properties and applications
Heitner-Wirguin, C. (1996) · Journal of Membrane Science · doi:10.1016/0376-7388(96)00155-x · Cited by 790
Electromechanical response of ionic polymer-metal composites
Nemat-Nasser, S., & Li, J. Y. (2000) · Journal of Applied Physics · doi:10.1063/1.372343 · Cited by 609
Self-citationMicromechanics of actuation of ionic polymer-metal composites
Nemat-Nasser, S. (2002) · Journal of Applied Physics · doi:10.1063/1.1495888 · Cited by 570
Self-citationShahinpoor, M., & Kim, K. J. (2000) · Smart Materials and Structures · doi:10.1088/0964-1726/9/4/318 · Cited by 283
Preparation of Gold−Solid Polymer Electrolyte Composites As Electric Stimuli-Responsive Materials
Fujiwara, N., Asaka, K., Nishimura, Y., Oguro, K., & Torikai, E. (2000) · Chemistry of Materials · doi:10.1021/cm9907357 · Cited by 152
Morphology of electrodes and bending response of the polymer electrolyte actuator
Onishi, K., Sewa, S., Asaka, K., Fujiwara, N., & Oguro, K. (2001) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00656-3 · Cited by 139
Onishi, K., Sewa, S., Asaka, K., Fujiwara, N., & Oguro, K. (2001) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00695-2 · Cited by 116
Polymer electrolyte actuator with gold electrodes
Oguro, K., Fujiwara, N., Asaka, K., Onishi, K., & Sewa, S. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.349698 · Cited by 97
Measurements and macro models of ionomeric polymer-metal composites (IPMC)
Bao, X. Q., Bar‐Cohen, Y., & Lih, S.-S. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.475167 · Cited by 86
Challenges to the application of IPMC as actuators of planetary mechanisms
Bar‐Cohen, Y., Leary, S. P., Yavrouian, A., Oguro, K., Tadokoro, S., Harrison, J. S., Smith, J. G., & Su, J. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.387772 · Cited by 84
Asaka, K., Fujiwara, N., Oguro, K., Onishi, K., & Sewa, S. (2001) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(01)00445-4 · Cited by 76
Cited by
Shintake, J., Cacucciolo, V., Floreano, D., & Shea, H. (2018) · Advanced Materials · doi:10.1002/adma.201707035 · Cited by 1,938
Advances in Dielectric Elastomers for Actuators and Artificial Muscles
Brochu, P., & Pei, Q. (2010) · Macromolecular Rapid Communications · doi:10.1002/marc.200900425 · Cited by 1,387
Artificial Muscles: Mechanisms, Applications, and Challenges
Mirvakili, S. M., & Hunter, I. W. (2018) · Advanced Materials · doi:10.1002/adma.201704407 · Cited by 1,077
Artificial Muscle Technology: Physical Principles and Naval Prospects
Madden, J. D. W., Vandesteeg, N. A., Anquetil, P. A., Madden, P. G. A., Takshi, A., Pytel, R. Z., Lafontaine, S. R., Wieringa, P. A., & Hunter, I. W. (2004) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2004.833135 · Cited by 1,035
Mirfakhrai, T., Madden, J. D. W., & Baughman, R. H. (2007) · Materials Today · doi:10.1016/s1369-7021(07)70048-2 · Cited by 933
Metadata
- Authors
- Nemat-Nasser, S., & Wu, Y.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2003-05-01
- Volume
- 93
- Issue
- 9
- Pages
- 5255-5267
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2007224752
- Cited by
- 381
- References
- 14
- FWCI
- 10.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.