The DOI matches its Crossref record.
Femtogram mass detection using photothermally actuated nanomechanical resonators
Abstract
Nanomechanical devices with very small mass and size have the potential for mass sensing at the level of individual molecules. In the present study, we designed nanomechanical mass sensors, demonstrated their operation under ambient pressure and temperature, and achieved femtogram-level mass sensitivity. Our nanomechanical resonators were gold-coated silicon cantilevers with resonance frequencies in the range of 1 to 10 MHz, characteristic thicknesses of 50–100 nm, and force constants of about 0.1 N/m. Using a cantilever with a resonant frequency of 2.2 MHz that was excited photothermally, we measured a mass change of 5.5 fg upon chemisorption of 11-mercaptoundecanoic acid. Our analysis indicates that, by decreasing the mass of the cantilever and increasing the excitation amplitude, even higher mass sensitivity can be realized in an easily accessible frequency range (<100 MHz).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ekinci, K. L., & Roukes, M. L. (2005) · Review of Scientific Instruments · doi:10.1063/1.1927327 · Cited by 1,374
Weighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Self-citationMicro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Atomic-Scale Mass Sensing Using Carbon Nanotube Resonators
Chiu, H.-Y., Hung, P., Postma, H. W. C., & Bockrath, M. (2008) · Nano Letters · doi:10.1021/nl802181c · Cited by 451
Metadata
- Authors
- Lavrik, N. V., & Datskos, P. G.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2003-04-21
- Volume
- 82
- Issue
- 16
- Pages
- 2697-2699
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2001710792
- Cited by
- 308
- References
- 0
- FWCI
- 21.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Femtogram mass detection using photothermally actuated nanomechanical resonators. https://app.cochat.ai/papers/10.1063/1.1569050
- The paper
- Lavrik, N. V., & Datskos, P. G. (2003). Femtogram mass detection using photothermally actuated nanomechanical resonators. Applied Physics Letters. https://doi.org/10.1063/1.1569050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.