Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 224

The DOI matches its Crossref record.

Single photon detector fabricated in a complementary metal–oxide–semiconductor high-voltage technology

Rochas, A., Gani, M., Furrer, B., Besse, P. A., Popovic, R. S., Ribordy, G., Gisin, N. · 2003 · Review of Scientific Instruments

Abstract

In this article, a fully integrated single photon detector including a silicon avalanche photodiode and a quenching circuit is presented. The low doping concentrations, inherent to the complementary metal–oxide–semiconductor (CMOS) high-voltage technology used, favor the absorption of red and infrared photons at the depletion region. The detection probability rapidly increases with excess bias voltages up to 5 V. At this value, the detection probability is larger than 20% between 420 nm and 620 nm and still 7% at 750 nm. The photosensitive area is 7 μm in diameter. Cointegration of the diode and the quenching resistor allows a drastic reduction of parasitic capacitances. Though passively quenched, the single photon detector exhibits a dead time as low as 75 ns. The avalanche current is quickly quenched in less than 3.5 ns leading to a relatively low afterpulsing probability of 7.5% at 5 V excess bias voltage. The afterpulses are located in the first microseconds after the avalanche event. At room temperature, the dark count rate is about 900 Hz at 5 V excess bias voltage. Cooling of the sensor below 0 °C is of minor interest since the tunneling process becomes dominant. A remarkably short timing resolution has been obtained with values lower than 50 ps for excess bias voltage higher than 5 V. The industrial CMOS high-voltage technology used guarantees low production costs. In applications where the light can be focused on the small photosensitive area using a high magnification objective, the fabricated single photon avalanche photodiode overcomes the features of standard photomultiplier tubes. The CMOS integration opens the way to the fabrication of an extremely compact array. The design can be easily fitted to a dedicated application. Furthermore, by using an industrial CMOS process, the cointegration of data processing electronics to produce a smart sensor would be a feasible task.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1584083

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Rochas, A., Gani, M., Furrer, B., Besse, P. A., Popovic, R. S., Ribordy, G., & Gisin, N.
Venue
Review of Scientific Instruments
Published
2003-07-01
Volume
74
Issue
7
Pages
3263-3270
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W1989917143
Cited by
224
References
0
FWCI
7.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.